System SP Tables-7


3.7 SYSTEM SP TABLES-7


3.7.1 SP7-XXX: DATA LOG


7401*

Total SC Counter


001

SC Counter

Displays the total number of service calls that have occurred.

This SC counter can be reset by executing SP7807 (SC/Jam Counter Reset).


002

Total SC Counter

Displays the cumulative sum of service calls that have occurred.

This SC counter cannot be reset by executing SP7807 (SC/Jam Counter Reset).



7403*

SC History

001

Latest


Displays the most recent 10 service calls.

002

Latest 1

003

Latest 2

004

Latest 3

005

Latest 4

006

Latest 5

007

Latest 6

008

Latest 7

009

Latest 8

010

Latest 9

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Tables-7



7404*

SC991 History

001

Latest


Displays the 10 most recently detected SC991 codes.

002

Latest 1

003

Latest 2

004

Latest 3

005

Latest 4

006

Latest 5

007

Latest 6

008

Latest 7

009

Latest 8

010

Latest 9



7502*

Total Paper Jam


001

Jam Counter

Displays the total number of paper jams.

This SC counter can be reset by executing SP7807 (SC/Jam Counter Reset).


002

Total Jam Counter

Displays the cumulative sum of paper jams.

This SC counter cannot be reset by executing SP7807 (SC/Jam Counter Reset).

System SP Tables-7



7503*

Total Original Jam


001

Original Jam Counter

Displays the total number of original jams.

This SC counter can be reset by executing SP7807 (SC/Jam Counter Reset).


002

Total Original Counter

Displays the cumulative sum of original jams.

This SC counter cannot be reset by executing SP7807 (SC/Jam Counter Reset).




7504*

Total Jams Location

These SPs display the total number of paper jams by location. A "Check-in" (paper late) error occurs when the paper fails to activate the sensor at the precise time. A "Check-out" ("paper lag") paper jam occurs when the paper remains at the sensor for longer than the prescribed time.

001

At power On

003

Tray 1: On

004

Tray 2: On

005

Tray 3: On

006

Tray 4: On

007

LCT: On

008

Bypass: On

009

Duplex: On

011

Vertical Transport 1: On

012

Vertical Transport 2: On

013

Bank: Transport Sn 1: On

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Tables-7



014

Bank: Transport Sn 2: On

017

Registration: On

019

Fusing Exit: On

020

Paper Exit: On

021

Bridge Exit On

022

Bridge Transport: On

024

Junction Gate Sensor: On

025

Duplex Exit: On

026

Duplex Entrance: On (In)

027

Duplex Entrance: On (Out)

051

Vertical Transport 1: Off

052

Vertical Transport 2: Off

053

Bank Transport 1: Off

054

Bank Transport 2: Off

057

Registration Sensor: Off

058

LCT Feed Sensor: Off

060

Paper Exit: Off

061

Bridge: Exit: Off

062

Bridge: Transport: Off

064

Junction Gate Sensor: Off

065

Duplex Exit: Off

066

Duplex Entrance: Off (In)

067

Duplex Entrance: Off (Out)

System SP Tables-7



100

Finisher Entrance: KIN

101

Finisher Shift Tray Exit: KIN

102

Finisher Staple: KIN

103

Finisher Exit: KIN

105

Finisher Tray Lift Motor: KIN

106

Finisher Jogger Motor: KIN

107

Finisher Shift Motor: KIN

108

Finisher Staple Motor: KIN

109

Finisher Exit Motor: KIN

191

Finisher Entrance: EUP

192

Finisher Proof Exit: EUP

193

Finisher Shift Tray Exit: EUP

194

Finisher Staple Exit: EUP

195

Finisher Exit: EUP

198

Finisher Folder: EUP

199

Finisher Tray Motor: EUP

200

Finisher Jogger Motor: EUP

201

Finisher Shift Motor: EUP

202

Finisher Staple Moving Motor: EUP

203

Finisher Staple Motor: EUP

204

Finisher Folder Motor: EUP

206

Finisher Punch Motor: EUP

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Tables-7




7505

Original Jam Detection

Displays the total number of original jams by location. These jams occur when the original does not activate the sensors. A Check-in ("paper late") error occurs when the paper fails to activate the sensor at the precise time. A Check-out ("paper lag") paper jam occurs when the paper remains at the sensor for longer than the prescribed time.

001

At Power: On

003

Separation Sensor: On

004

Skew Correction Sensor: On

005

Interval Sensor: On

006

Registration Sensor: On

007

Inverter Sensor: On

008

Original Exit Sensor: On

053

Separation Sensor: Off

054

Skew Correction Sensor: Off

055

Interval Sensor: Off

056

Registration Sensor: Off

057

Inverter Sensor: Off

058

Original Exit Sensor: Off

System SP Tables-7



7506*

Jam Count by Paper Size

005

A4 LEF


Displays the total number of copy jams by paper size.

006

A5 LEF

014

B5 LEF

038

LT LEF

044

HLT LEF

132

A3 SEF

133

A4 SEF

134

A5 SEF

141

B4 SEF

142

B5 SEF

160

DLT SEF

164

LG SEF

166

LT SEF

172

HLT SEF

255

Others

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Tables-7



7507*

Plotter

Jam

History

001

Last


002

Latest 1


Displays the copy jam history (the most recent 10 jams)

003

Latest 2

Sample Display:

CODE:007

004

Latest 3

SIZE:05h

005

Latest 4

TOTAL:0000334

DATE: Mon Mar 15 11:44:50 2000

006

Latest 5

where:

007

Latest 6

CODE is the SP7504-*** number (see above.

SIZE is the ASAP paper size code in hex.

008

Latest 7

TOTAL is the total jam error count (SP7502)

009

Latest 8

DATE is the date the jams occurred.

010

Latest 9


Size

Code

Size

Code

Size

Code

A4 (S)

05

A3 (L)

84

DLT (L)

A0

A5 (S)

06

A4 (L)

85

LG (L)

A4

B5 (S)

0E

A5 (L)

86

LT (L)

A6

LT (S)

26

B4 (L)

8D

HLT (L)

AC

HLT (S)

2C

B5 (L)

8E

Others

FF

System SP Tables-7



7508*

Original

Jam

History

001

Last



002

Last 1


Displays the original jam history (the most recent 10 jams).

003

Last 2

Sample Display:

CODE:007

004

Last 3

SIZE:05h

005

Last 4

TOTAL:0000334

DATE: Mon Mar 15 11:44:50 2000

006

Last 5

where:

007

Last 6

CODE is the SP7505*** number (see above.

SIZE is the ASAP paper size code in hex.

008

Last 7

TOTAL is the total jam error count (SP7503)

009

Last 8

DATE is the date the jams occurred.

010

Last 9


Size

Code

Size

Code

Size

Code


A4 (S)

05

A3 (L)

84

DLT (L)

A0


A5 (S)

06

A4 (L)

85

LG (L)

A4


B5 (S)

0E

A5 (L)

86

LT (L)

A6


LT (S)

26

B4 (L)

8D

HLT (L)

AC


HLT (S)

2C

B5 (L)

8E

Others

FF


Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Tables-7




7624*

Part Replacement Operation

Selects the PM maintenance for each part.

001

PCU-BK


[0 to 1 / 1 / 1]

0:No (Not PM maintenance) 1: Yes (PM maintenance)

002

Fuser

003

Transfer Unit

004

FuserCleaner




7801

ROM No./Firmware Version

This SP codes display the firmware versions of all ROMs in the system, including the mainframe, the ARDF, and peripheral devices.




7803*

PM Counter Display

Displays the PM counter since the last PM.


001

Paper

[0 to 999999 / 0 / 1 page]

Displays the paper counter (pages)


002

Page: PCD

[0 to 999999 / 0 / 1 page]

Displays the PCD (Drum and Development unit) counter (pages)


003

Page: Transfer

[0 to 999999 / 0 / 1 page]

Displays the transfer unit counter (pages).


004

Page: Fuser

[0 to 999999 / 0 / 1 page]

Displays the fusing unit counter (pages).


005

Rotation: PCD

[0 to 999999999 / 0 / 1 mm ]

Displays the PCD rotation counter (distance).

System SP Tables-7




006

Rotation: Transfer

[0 to 999999999 / 0 / 1 mm ]

Displays the transfer unit rotation counter (distance).


007

Rotation: Fuser

[0 to 999999999 / 0 / 1 mm ]

Displays the fuser unit rotation counter (distance).


008

Rotation(%): PCD

[0 to 255 / 0 / 1 %]

Displays the PCD (%) rotation counter (Distance/PM).


009

Rotation(%):Transfer

[0 to 255 / 0 / 1 %]

Displays the transfer unit (%) rotation counter (distance/PM).


010

Rotation(%):Fuser

[0 to 255 / 0 / 1 %]

Displays the fuser unit (%) rotation counter (distance/PM).


011

Rotation(%):Web

[0 to 255 / 0 / 1 %]

Displays the web unit (%) rotation counter (distance/PM).




7804

PM Counter Reset

Resets the PM counter.

Touch [Execute] two times > "Completed" > [Exit]


001

Paper

Resets the PM counter of the paper.


002

PCD

Resets the PM counter of the PCD (Drum and Development unit except developer).


003

Transfer

Resets the PM counter of the transfer unit.

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Tables-7




004

Fuser

Resets the PM counter of the fuser unit.


005

Web

Reset the PM counter of the web unit.


006

All Clear

Resets all PM counter



7805

Parts Counter


001

Page: OPC

[0 to 999999 / 0 / 1 page]

Displays the parts counter (pages) of the OPC.


002

Page: Charge Roller

[0 to 999999 / 0 / 1 page]

Displays the parts counter (pages) of the charge roller.


003

Page: Developer

[0 to 999999 / 0 / 1 page]

Displays the parts counter (pages) of the developer.


004

Page: Belt Blade

[0 to 999999 / 0 / 1 page]

Displays the parts counter (pages) of the transfer belt cleaning blade.


005

Page: Heat Roller

[0 to 999999 / 0 / 1 page]

Displays the parts counter (pages) of the hot roller.


006

Page: Pressure Roller

[0 to 999999 / 0 / 1 page]

Displays the parts counter (pages) of the pressure roller.


007

Page: Cleaning Roller

[0 to 999999 / 0 / 1 page]

Displays the parts counter (pages) of the cleaning roller.


008

Page: Thermistor

[0 to 999999 / 0 / 1 page]

Displays the parts counter (pages) of the thermistors.

System SP Tables-7




009

Page: Stripper

[0 to 999999 / 0 / 1 page]

Displays the parts counter (pages) of the strippers.


010

Rotation: OPC

[0 to 999999999 / 0 / 1 mm ]

Displays the parts counter (rotations) of the OPC.


011

Rotation: Charge Roller

[0 to 999999999 / 0 / 1 mm ]

Displays the parts counter (rotations) of the charge roller.


012

Rotation: Developer

[0 to 999999999 / 0 / 1 mm ]

Displays the parts counter (rotations) of the developer.


013

Rotation: Belt Blade

[0 to 999999999 / 0 / 1 mm ]

Displays the parts counter (rotations) of the transfer belt, blade.


014

Rotation: Heat Roller

[0 to 999999999 / 0 / 1 mm ]

Displays the parts counter (rotations) of the hot roller.


015

Rotation: Pressure Roller

[0 to 999999999 / 0 / 1 mm ]

Displays the parts counter (rotations) of the pressure roller.


016

Rotation: Cleaning Roller

[0 to 999999999 / 0 / 1 mm ]

Displays the parts counter (rotations) of the cleaning roller.


017

Rotation: Thermistor

[0 to 999999999 / 0 / 1 mm ]

Displays the parts counter (rotations) of the thermistors.


018

Rotation: Stripper

[0 to 999999999 / 0 / 1 mm ]

Displays the parts counter (rotations) of the strippers.


019

Page(%): Web

[0 to 255 / 0 / 1 %]

Displays the parts counter (rotations/PM %) of the cleaning web.

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Tables-7



7806

Counter Clear


001

OPC


Resets the parts counter of the OPC.


002

Charge Roller


Resets the parts counter of the charge roller.


003

Developer


Resets the parts counter of the developer.


004

Belt: Blade


Resets the parts counter of the transfer belt cleaning blade.


005

Heat Roller


Resets the parts counter of the hot roller.


006

Pressure Roller


Resets the parts counter of the pressure roller.


007

Cleaning Roller


Resets the parts counter of the cleaning roller.


008

Web


Resets the parts counter of the cleaning web.


009

Thermistor


Resets the parts counter of the thermistors.


010

Stripper


Resets the parts counter of the strippers.


011

All Clear


Resets all parts counters.

System SP Tables-7




7807

SC/Jam Counter Reset

Resets the SC and jam counters. To reset, press Execute on the touch panel.

This SP does not reset the jam history counters: SP7507, SP7508.




7826

MF Error Counter Japan Only

Displays the number of counts requested of the card/key counter.


001


Error Total

A request for the count total failed at power on. This error will occur if the device is installed but disconnected.


002


Error Staple

The request for a staple count failed at power on. This error will occur if the device is installed but disconnected.




7827

MF Error Counter Clear Japan Only

Press Execute to reset to 0 the values of SP7826. Japan Only




7832

Self-Diagnose Result Display

Execute to open the "Self-Diagnostics Result Display" to view details about errors. Use the keys in the display on the touch-panel to scroll through all the information. If no errors have occurred, you will see the "No Error" message on the screen.




7836

Total Memory Size

Displays the memory capacity of the controller system.

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Tables-7




7852*

DF Glass Dust Check

Counts the number of occurrences (0 to 65,535) when dust was detected on the scanning glass of the ADF or resets the dust detection counter.

Counting is done only if SP4-020-1 (Dust Check) is switched on.

001

Dust Detection Counter

[0 to 65535 / 0 / 1 /step]


002

Dust Detection Clear Counter


[0 to 65535 / 0 / 1 /step]



7853

Replacement Counter


001

PCD

[0 to 255 / 0 / 1 ]

Displays the replacement counter of the PCD (Drum and Development unit).


002

Transfer

[0 to 255 / 0 / 1 ]

Displays the replacement counter of the transfer unit.


003

Fuser

[0 to 255 / 0 / 1 ]

Displays the replacement counter of the fusing unit.


004

Web

[0 to 255 / 0 / 1 ]

Displays the replacement counter of the cleaning web.




7856*

zero cross

[0 to 255 / 60 / 1 ]

Stores and displays the detected zero cross frequency of the main ac power supply from the wall socket.

System SP Tables-7




7901

Assert Info. DFU

These SP numbers display the results of the occurrence of the most recent SC code generated by the machine.

001*

File Name

Module name

002*

Number of Lines

Number of the lines where error occurred.

003*

Location

Value



7906

Prev Counter


001

Page: PCD

[0 to 999999 / 0 / 1 page]

Displays the counter (pages) of the previous PCD


002

Page: Transfer

[0 to 999999 / 0 / 1 page]

Displays the previous counter (pages) of the previous transfer unit.


003

Page: Fuser

[0 to 999999 / 0 / 1 page]

Displays the previous counter (pages) of the previous fusing unit.


004

Rotation: PCD

[0 to 999999999 / 0 / 1 mm ]

Displays the previous counter (rotations) of the previous PCD


005

Rotation: Transfer

[0 to 999999999 / 0 / 1 mm ]

Displays the previous counter (rotations) of the previous transfer unit.


006

Rotation: Fuser

[0 to 999999999 / 0 / 1 mm ]

Displays the previous counter (rotations/PM %) of the previous fusing unit.


007

Rotation(%):PCD

[0 to 255 / 0 / 1 mm]

Displays the previous counter (rotations/PM %) of the previous PCD

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Tables-7




008

Rotation(%):Transfer

[0 to 255 / 0 / 1 mm]

Displays the previous counter (rotations/PM %) of the previous transfer unit.


009

Rotation(%):Fuser

[0 to 255 / 0 / 1 mm]

Displays the previous counter (rotations/PM %) of the previous fusing unit.


010

Rotation(%):Web

[0 to 255 / 0 / 1 %]

Displays the previous counter (rotations/PM %) of the previous cleaning web.



7950

Replacement Date


001

PCD

Displays the replacement date of the PCD.


002

Transfer

Displays the replacement date of the transfer unit.


003

Fuser

Displays the replacement date of the fusing unit.


004

Web

Displays the replacement date of the web unit.

System SP Tables-7



7951

Remaining Counter


001

PCD(Page)

[0 to 255 / 255 / 1 days]

Displays the remaining counter (pages) of the PCD.


002

Transfer(Page)

[0 to 255 / 255 / 1 days]

Displays the remaining counter (pages) of the transfer unit.


003

Fuser(Page)

[0 to 255 / 255 / 1 days]

Displays the remaining counter (pages) of the fusing unit.


005

PCD(Rotation)

[0 to 255 / 255 / 1 days]

Displays the remaining counter (rotations) of the PCD.


006

Transfer(Rotation)

[0 to 255 / 255 / 1 days]

Displays the remaining counter (rotations) of the transfer unit.


007

Fuser(Rotation)

[0 to 255 / 255 / 1 days]

Displays the remaining counter (rotations) of the fusing unit.


009

PCD (%)

[0 to 255 / 100 / 1 %]

Displays the remaining counter (%) of the PCD.


010

Transfer (%)

[0 to 255 / 100 / 1 %]

Displays the remaining counter (%) of the transfer unit.


011

Fuser (%)

[0 to 255 / 100 / 1 %]

Displays the remaining counter (%) of the fusing unit.


013

Web (%)

[0 to 255 / 100 / 1 %]

Displays the remaining counter (%) of the cleaning web.

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Tables-7




7952

PM Yield Setting

Sets the each yield of the following.


001

PCD(Page)

[0 to 99999999/ 160000 / 1 sheet]

Sets the PM yield of the PCD (Pages).


002

Transfer(Page)

[0 to 9999999 / 160000 / 1 sheet]

Sets the PM yield of the transfer unit (Pages).


003

Fuser(Page)

[0 to 9999999 / 160000 / 1 sheet]

Sets the PM yield of the fusing unit (Pages).


005


PCD(Rotation)

C2b: [0 to 999999999 / 71990000 / 1 mm]

C2c: [0 to 999999999 / 75500000 / 1 mm]

Sets the PM yield of the PCD (Rotations).


006


Transfer(Rotation)

C2b: [0 to 999999999 / 62770000 / 1 mm]

C2c: [0 to 999999999 / 65420000 / 1 mm]

Sets the PM yield of the transfer unit (Rotations).


007


Fuser(Rotation)

C2b: [0 to 999999999 / 54880000 / 1 mm]

C2b: [0 to 999999999 / 55800000 / 1 mm]

Sets the PM yield of the fusing unit (Rotations).


009

Web (%)

[0 to 255 / 92 / 1 %]

Sets the PM yield (%) of the web unit.


021

Day Threshold: PCD

[1 to 30 / 15 / 1 days]

Adjusts the threshold day for the near end for the PCD.


022

Day Threshold: Transfer Unit

[1 to 30 / 15 / 1 days]

Adjusts the threshold day for the near end for the transfer unit.


023

Day Threshold: Fusing Unit

[1 to 30 / 15 / 1 days]

Adjusts the threshold day for the near end for the fusing unit.

System SP Tables-7



7953

Operation Env Log


001

T<10

[0 to 99999999 / 0 / 1 mm]

Displays the PCU rotation distance in the environment: T<10°C


002

10<=T<=17

[0 to 99999999 / 0 / 1 mm]

Displays the PCU rotation distance in the environment: 10°C<=T<=17°C


003

17<T<23

[0 to 99999999 / 0 / 1 mm]

Displays the PCU rotation distance in the environment: 17<=T<=23


004

23<=T<=27

[0 to 99999999 / 0 / 1 mm]

Displays the PCU rotation distance of the environment: 23<=T<=27


005

27<=T<=32

[0 to 99999999 / 0 / 1 mm]

Displays the PCU rotation distance of the environment: 27<=T<=32


006

32<T

[0 to 99999999 / 0 / 1 mm]

Displays the PCU rotation distance of the environment: 32<T




7954

Env Log Clear

Resets the environment logs (SP7953).