HOME PAGE | < Previous | Contents | Next >
3.7 SYSTEM SP TABLES-7
3.7.1 SP7-XXX: DATA LOG
7401* | Total SC Counter |
001 | SC Counter |
Displays the total number of service calls that have occurred. This SC counter can be reset by executing SP7807 (SC/Jam Counter Reset). | |
002 | Total SC Counter |
Displays the cumulative sum of service calls that have occurred. This SC counter cannot be reset by executing SP7807 (SC/Jam Counter Reset). |
7403* | SC History | |
001 | Latest | Displays the most recent 10 service calls. |
002 | Latest 1 | |
003 | Latest 2 | |
004 | Latest 3 | |
005 | Latest 4 | |
006 | Latest 5 | |
007 | Latest 6 | |
008 | Latest 7 | |
009 | Latest 8 | |
010 | Latest 9 |
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
System SP Tables-7
7404* | SC991 History | |
001 | Latest | Displays the 10 most recently detected SC991 codes. |
002 | Latest 1 | |
003 | Latest 2 | |
004 | Latest 3 | |
005 | Latest 4 | |
006 | Latest 5 | |
007 | Latest 6 | |
008 | Latest 7 | |
009 | Latest 8 | |
010 | Latest 9 |
7502* | Total Paper Jam |
001 | Jam Counter |
Displays the total number of paper jams. This SC counter can be reset by executing SP7807 (SC/Jam Counter Reset). | |
002 | Total Jam Counter |
Displays the cumulative sum of paper jams. This SC counter cannot be reset by executing SP7807 (SC/Jam Counter Reset). |
System SP Tables-7
7503* | Total Original Jam |
001 | Original Jam Counter |
Displays the total number of original jams. This SC counter can be reset by executing SP7807 (SC/Jam Counter Reset). | |
002 | Total Original Counter |
Displays the cumulative sum of original jams. This SC counter cannot be reset by executing SP7807 (SC/Jam Counter Reset). |
7504* | Total Jams Location |
These SPs display the total number of paper jams by location. A "Check-in" (paper late) error occurs when the paper fails to activate the sensor at the precise time. A "Check-out" ("paper lag") paper jam occurs when the paper remains at the sensor for longer than the prescribed time. | |
001 | At power On |
003 | Tray 1: On |
004 | Tray 2: On |
005 | Tray 3: On |
006 | Tray 4: On |
007 | LCT: On |
008 | Bypass: On |
009 | Duplex: On |
011 | Vertical Transport 1: On |
012 | Vertical Transport 2: On |
013 | Bank: Transport Sn 1: On |
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
System SP Tables-7
014 | Bank: Transport Sn 2: On |
017 | Registration: On |
019 | Fusing Exit: On |
020 | Paper Exit: On |
021 | Bridge Exit On |
022 | Bridge Transport: On |
024 | Junction Gate Sensor: On |
025 | Duplex Exit: On |
026 | Duplex Entrance: On (In) |
027 | Duplex Entrance: On (Out) |
051 | Vertical Transport 1: Off |
052 | Vertical Transport 2: Off |
053 | Bank Transport 1: Off |
054 | Bank Transport 2: Off |
057 | Registration Sensor: Off |
058 | LCT Feed Sensor: Off |
060 | Paper Exit: Off |
061 | Bridge: Exit: Off |
062 | Bridge: Transport: Off |
064 | Junction Gate Sensor: Off |
065 | Duplex Exit: Off |
066 | Duplex Entrance: Off (In) |
067 | Duplex Entrance: Off (Out) |
System SP Tables-7
100 | Finisher Entrance: KIN |
101 | Finisher Shift Tray Exit: KIN |
102 | Finisher Staple: KIN |
103 | Finisher Exit: KIN |
105 | Finisher Tray Lift Motor: KIN |
106 | Finisher Jogger Motor: KIN |
107 | Finisher Shift Motor: KIN |
108 | Finisher Staple Motor: KIN |
109 | Finisher Exit Motor: KIN |
191 | Finisher Entrance: EUP |
192 | Finisher Proof Exit: EUP |
193 | Finisher Shift Tray Exit: EUP |
194 | Finisher Staple Exit: EUP |
195 | Finisher Exit: EUP |
198 | Finisher Folder: EUP |
199 | Finisher Tray Motor: EUP |
200 | Finisher Jogger Motor: EUP |
201 | Finisher Shift Motor: EUP |
202 | Finisher Staple Moving Motor: EUP |
203 | Finisher Staple Motor: EUP |
204 | Finisher Folder Motor: EUP |
206 | Finisher Punch Motor: EUP |
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
System SP Tables-7
7505 | Original Jam Detection |
Displays the total number of original jams by location. These jams occur when the original does not activate the sensors. A Check-in ("paper late") error occurs when the paper fails to activate the sensor at the precise time. A Check-out ("paper lag") paper jam occurs when the paper remains at the sensor for longer than the prescribed time. | |
001 | At Power: On |
003 | Separation Sensor: On |
004 | Skew Correction Sensor: On |
005 | Interval Sensor: On |
006 | Registration Sensor: On |
007 | Inverter Sensor: On |
008 | Original Exit Sensor: On |
053 | Separation Sensor: Off |
054 | Skew Correction Sensor: Off |
055 | Interval Sensor: Off |
056 | Registration Sensor: Off |
057 | Inverter Sensor: Off |
058 | Original Exit Sensor: Off |
System SP Tables-7
7506* | Jam Count by Paper Size | |
005 | A4 LEF | Displays the total number of copy jams by paper size. |
006 | A5 LEF | |
014 | B5 LEF | |
038 | LT LEF | |
044 | HLT LEF | |
132 | A3 SEF | |
133 | A4 SEF | |
134 | A5 SEF | |
141 | B4 SEF | |
142 | B5 SEF | |
160 | DLT SEF | |
164 | LG SEF | |
166 | LT SEF | |
172 | HLT SEF | |
255 | Others |
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
System SP Tables-7
7507* | Plotter | Jam | History | |||
001 | Last | |||||
002 | Latest 1 | Displays the copy jam history (the most recent 10 jams) | ||||
003 | Latest 2 | Sample Display: | ||||
CODE:007 | ||||||
004 | Latest 3 | |||||
SIZE:05h | ||||||
005 | Latest 4 | TOTAL:0000334 | ||||
DATE: Mon Mar 15 11:44:50 2000 | ||||||
006 | Latest 5 | |||||
where: | ||||||
007 | Latest 6 | CODE is the SP7504-*** number (see above. | ||||
SIZE is the ASAP paper size code in hex. | ||||||
008 | Latest 7 | |||||
TOTAL is the total jam error count (SP7502) | ||||||
009 | Latest 8 | DATE is the date the jams occurred. | ||||
010 | Latest 9 | |||||
Size | Code | Size | Code | Size | Code | |
A4 (S) | 05 | A3 (L) | 84 | DLT (L) | A0 | |
A5 (S) | 06 | A4 (L) | 85 | LG (L) | A4 | |
B5 (S) | 0E | A5 (L) | 86 | LT (L) | A6 | |
LT (S) | 26 | B4 (L) | 8D | HLT (L) | AC | |
HLT (S) | 2C | B5 (L) | 8E | Others | FF |
System SP Tables-7
7508* | Original | Jam | History | ||||
001 | Last | ||||||
002 | Last 1 | Displays the original jam history (the most recent 10 jams). | |||||
003 | Last 2 | Sample Display: | |||||
CODE:007 | |||||||
004 | Last 3 | ||||||
SIZE:05h | |||||||
005 | Last 4 | TOTAL:0000334 | |||||
DATE: Mon Mar 15 11:44:50 2000 | |||||||
006 | Last 5 | ||||||
where: | |||||||
007 | Last 6 | CODE is the SP7505*** number (see above. | |||||
SIZE is the ASAP paper size code in hex. | |||||||
008 | Last 7 | ||||||
TOTAL is the total jam error count (SP7503) | |||||||
009 | Last 8 | DATE is the date the jams occurred. | |||||
010 | Last 9 | ||||||
Size | Code | Size | Code | Size | Code | ||
A4 (S) | 05 | A3 (L) | 84 | DLT (L) | A0 | ||
A5 (S) | 06 | A4 (L) | 85 | LG (L) | A4 | ||
B5 (S) | 0E | A5 (L) | 86 | LT (L) | A6 | ||
LT (S) | 26 | B4 (L) | 8D | HLT (L) | AC | ||
HLT (S) | 2C | B5 (L) | 8E | Others | FF |
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
System SP Tables-7
7624* | Part Replacement Operation | |
Selects the PM maintenance for each part. | ||
001 | PCU-BK | [0 to 1 / 1 / 1] 0:No (Not PM maintenance) 1: Yes (PM maintenance) |
002 | Fuser | |
003 | Transfer Unit | |
004 | FuserCleaner |
7801 | ROM No./Firmware Version |
This SP codes display the firmware versions of all ROMs in the system, including the mainframe, the ARDF, and peripheral devices. |
7803* | PM Counter Display | |
Displays the PM counter since the last PM. | ||
001 | Paper | [0 to 999999 / 0 / 1 page] |
Displays the paper counter (pages) | ||
002 | Page: PCD | [0 to 999999 / 0 / 1 page] |
Displays the PCD (Drum and Development unit) counter (pages) | ||
003 | Page: Transfer | [0 to 999999 / 0 / 1 page] |
Displays the transfer unit counter (pages). | ||
004 | Page: Fuser | [0 to 999999 / 0 / 1 page] |
Displays the fusing unit counter (pages). | ||
005 | Rotation: PCD | [0 to 999999999 / 0 / 1 mm ] |
Displays the PCD rotation counter (distance). |
System SP Tables-7
006 | Rotation: Transfer | [0 to 999999999 / 0 / 1 mm ] |
Displays the transfer unit rotation counter (distance). | ||
007 | Rotation: Fuser | [0 to 999999999 / 0 / 1 mm ] |
Displays the fuser unit rotation counter (distance). | ||
008 | Rotation(%): PCD | [0 to 255 / 0 / 1 %] |
Displays the PCD (%) rotation counter (Distance/PM). | ||
009 | Rotation(%):Transfer | [0 to 255 / 0 / 1 %] |
Displays the transfer unit (%) rotation counter (distance/PM). | ||
010 | Rotation(%):Fuser | [0 to 255 / 0 / 1 %] |
Displays the fuser unit (%) rotation counter (distance/PM). | ||
011 | Rotation(%):Web | [0 to 255 / 0 / 1 %] |
Displays the web unit (%) rotation counter (distance/PM). |
7804 | PM Counter Reset |
Resets the PM counter. Touch [Execute] two times > "Completed" > [Exit] | |
001 | Paper |
Resets the PM counter of the paper. | |
002 | PCD |
Resets the PM counter of the PCD (Drum and Development unit except developer). | |
003 | Transfer |
Resets the PM counter of the transfer unit. |
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
System SP Tables-7
004 | Fuser |
Resets the PM counter of the fuser unit. | |
005 | Web |
Reset the PM counter of the web unit. | |
006 | All Clear |
Resets all PM counter |
7805 | Parts Counter | |
001 | Page: OPC | [0 to 999999 / 0 / 1 page] |
Displays the parts counter (pages) of the OPC. | ||
002 | Page: Charge Roller | [0 to 999999 / 0 / 1 page] |
Displays the parts counter (pages) of the charge roller. | ||
003 | Page: Developer | [0 to 999999 / 0 / 1 page] |
Displays the parts counter (pages) of the developer. | ||
004 | Page: Belt Blade | [0 to 999999 / 0 / 1 page] |
Displays the parts counter (pages) of the transfer belt cleaning blade. | ||
005 | Page: Heat Roller | [0 to 999999 / 0 / 1 page] |
Displays the parts counter (pages) of the hot roller. | ||
006 | Page: Pressure Roller | [0 to 999999 / 0 / 1 page] |
Displays the parts counter (pages) of the pressure roller. | ||
007 | Page: Cleaning Roller | [0 to 999999 / 0 / 1 page] |
Displays the parts counter (pages) of the cleaning roller. | ||
008 | Page: Thermistor | [0 to 999999 / 0 / 1 page] |
Displays the parts counter (pages) of the thermistors. |
System SP Tables-7
009 | Page: Stripper | [0 to 999999 / 0 / 1 page] |
Displays the parts counter (pages) of the strippers. | ||
010 | Rotation: OPC | [0 to 999999999 / 0 / 1 mm ] |
Displays the parts counter (rotations) of the OPC. | ||
011 | Rotation: Charge Roller | [0 to 999999999 / 0 / 1 mm ] |
Displays the parts counter (rotations) of the charge roller. | ||
012 | Rotation: Developer | [0 to 999999999 / 0 / 1 mm ] |
Displays the parts counter (rotations) of the developer. | ||
013 | Rotation: Belt Blade | [0 to 999999999 / 0 / 1 mm ] |
Displays the parts counter (rotations) of the transfer belt, blade. | ||
014 | Rotation: Heat Roller | [0 to 999999999 / 0 / 1 mm ] |
Displays the parts counter (rotations) of the hot roller. | ||
015 | Rotation: Pressure Roller | [0 to 999999999 / 0 / 1 mm ] |
Displays the parts counter (rotations) of the pressure roller. | ||
016 | Rotation: Cleaning Roller | [0 to 999999999 / 0 / 1 mm ] |
Displays the parts counter (rotations) of the cleaning roller. | ||
017 | Rotation: Thermistor | [0 to 999999999 / 0 / 1 mm ] |
Displays the parts counter (rotations) of the thermistors. | ||
018 | Rotation: Stripper | [0 to 999999999 / 0 / 1 mm ] |
Displays the parts counter (rotations) of the strippers. | ||
019 | Page(%): Web | [0 to 255 / 0 / 1 %] |
Displays the parts counter (rotations/PM %) of the cleaning web. |
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
System SP Tables-7
7806 | Counter Clear | |
001 | OPC | |
Resets the parts counter of the OPC. | ||
002 | Charge Roller | |
Resets the parts counter of the charge roller. | ||
003 | Developer | |
Resets the parts counter of the developer. | ||
004 | Belt: Blade | |
Resets the parts counter of the transfer belt cleaning blade. | ||
005 | Heat Roller | |
Resets the parts counter of the hot roller. | ||
006 | Pressure Roller | |
Resets the parts counter of the pressure roller. | ||
007 | Cleaning Roller | |
Resets the parts counter of the cleaning roller. | ||
008 | Web | |
Resets the parts counter of the cleaning web. | ||
009 | Thermistor | |
Resets the parts counter of the thermistors. | ||
010 | Stripper | |
Resets the parts counter of the strippers. | ||
011 | All Clear | |
Resets all parts counters. |
System SP Tables-7
7807 | SC/Jam Counter Reset |
Resets the SC and jam counters. To reset, press Execute on the touch panel. This SP does not reset the jam history counters: SP7507, SP7508. |
7826 | MF Error Counter Japan Only | |
Displays the number of counts requested of the card/key counter. | ||
001 | Error Total | A request for the count total failed at power on. This error will occur if the device is installed but disconnected. |
002 | Error Staple | The request for a staple count failed at power on. This error will occur if the device is installed but disconnected. |
7827 | MF Error Counter Clear Japan Only |
Press Execute to reset to 0 the values of SP7826. Japan Only |
7832 | Self-Diagnose Result Display |
Execute to open the "Self-Diagnostics Result Display" to view details about errors. Use the keys in the display on the touch-panel to scroll through all the information. If no errors have occurred, you will see the "No Error" message on the screen. |
7836 | Total Memory Size |
Displays the memory capacity of the controller system. |
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
System SP Tables-7
7852* | DF Glass Dust Check | |
Counts the number of occurrences (0 to 65,535) when dust was detected on the scanning glass of the ADF or resets the dust detection counter. Counting is done only if SP4-020-1 (Dust Check) is switched on. | ||
001 | Dust Detection Counter | [0 to 65535 / 0 / 1 /step] |
002 | Dust Detection Clear Counter | [0 to 65535 / 0 / 1 /step] |
7853 | Replacement Counter | |
001 | PCD | [0 to 255 / 0 / 1 ] |
Displays the replacement counter of the PCD (Drum and Development unit). | ||
002 | Transfer | [0 to 255 / 0 / 1 ] |
Displays the replacement counter of the transfer unit. | ||
003 | Fuser | [0 to 255 / 0 / 1 ] |
Displays the replacement counter of the fusing unit. | ||
004 | Web | [0 to 255 / 0 / 1 ] |
Displays the replacement counter of the cleaning web. |
7856* | zero cross | [0 to 255 / 60 / 1 ] |
Stores and displays the detected zero cross frequency of the main ac power supply from the wall socket. |
System SP Tables-7
7901 | Assert Info. DFU | |
These SP numbers display the results of the occurrence of the most recent SC code generated by the machine. | ||
001* | File Name | Module name |
002* | Number of Lines | Number of the lines where error occurred. |
003* | Location | Value |
7906 | Prev Counter | |
001 | Page: PCD | [0 to 999999 / 0 / 1 page] |
Displays the counter (pages) of the previous PCD | ||
002 | Page: Transfer | [0 to 999999 / 0 / 1 page] |
Displays the previous counter (pages) of the previous transfer unit. | ||
003 | Page: Fuser | [0 to 999999 / 0 / 1 page] |
Displays the previous counter (pages) of the previous fusing unit. | ||
004 | Rotation: PCD | [0 to 999999999 / 0 / 1 mm ] |
Displays the previous counter (rotations) of the previous PCD | ||
005 | Rotation: Transfer | [0 to 999999999 / 0 / 1 mm ] |
Displays the previous counter (rotations) of the previous transfer unit. | ||
006 | Rotation: Fuser | [0 to 999999999 / 0 / 1 mm ] |
Displays the previous counter (rotations/PM %) of the previous fusing unit. | ||
007 | Rotation(%):PCD | [0 to 255 / 0 / 1 mm] |
Displays the previous counter (rotations/PM %) of the previous PCD |
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
System SP Tables-7
008 | Rotation(%):Transfer | [0 to 255 / 0 / 1 mm] |
Displays the previous counter (rotations/PM %) of the previous transfer unit. | ||
009 | Rotation(%):Fuser | [0 to 255 / 0 / 1 mm] |
Displays the previous counter (rotations/PM %) of the previous fusing unit. | ||
010 | Rotation(%):Web | [0 to 255 / 0 / 1 %] |
Displays the previous counter (rotations/PM %) of the previous cleaning web. |
7950 | Replacement Date |
001 | PCD |
Displays the replacement date of the PCD. | |
002 | Transfer |
Displays the replacement date of the transfer unit. | |
003 | Fuser |
Displays the replacement date of the fusing unit. | |
004 | Web |
Displays the replacement date of the web unit. |
System SP Tables-7
7951 | Remaining Counter | |
001 | PCD(Page) | [0 to 255 / 255 / 1 days] |
Displays the remaining counter (pages) of the PCD. | ||
002 | Transfer(Page) | [0 to 255 / 255 / 1 days] |
Displays the remaining counter (pages) of the transfer unit. | ||
003 | Fuser(Page) | [0 to 255 / 255 / 1 days] |
Displays the remaining counter (pages) of the fusing unit. | ||
005 | PCD(Rotation) | [0 to 255 / 255 / 1 days] |
Displays the remaining counter (rotations) of the PCD. | ||
006 | Transfer(Rotation) | [0 to 255 / 255 / 1 days] |
Displays the remaining counter (rotations) of the transfer unit. | ||
007 | Fuser(Rotation) | [0 to 255 / 255 / 1 days] |
Displays the remaining counter (rotations) of the fusing unit. | ||
009 | PCD (%) | [0 to 255 / 100 / 1 %] |
Displays the remaining counter (%) of the PCD. | ||
010 | Transfer (%) | [0 to 255 / 100 / 1 %] |
Displays the remaining counter (%) of the transfer unit. | ||
011 | Fuser (%) | [0 to 255 / 100 / 1 %] |
Displays the remaining counter (%) of the fusing unit. | ||
013 | Web (%) | [0 to 255 / 100 / 1 %] |
Displays the remaining counter (%) of the cleaning web. |
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
Appendix: Service Program Mode Tables
System SP Tables-7
7952 | PM Yield Setting | |
Sets the each yield of the following. | ||
001 | PCD(Page) | [0 to 99999999/ 160000 / 1 sheet] |
Sets the PM yield of the PCD (Pages). | ||
002 | Transfer(Page) | [0 to 9999999 / 160000 / 1 sheet] |
Sets the PM yield of the transfer unit (Pages). | ||
003 | Fuser(Page) | [0 to 9999999 / 160000 / 1 sheet] |
Sets the PM yield of the fusing unit (Pages). | ||
005 | PCD(Rotation) | C2b: [0 to 999999999 / 71990000 / 1 mm] C2c: [0 to 999999999 / 75500000 / 1 mm] |
Sets the PM yield of the PCD (Rotations). | ||
006 | Transfer(Rotation) | C2b: [0 to 999999999 / 62770000 / 1 mm] C2c: [0 to 999999999 / 65420000 / 1 mm] |
Sets the PM yield of the transfer unit (Rotations). | ||
007 | Fuser(Rotation) | C2b: [0 to 999999999 / 54880000 / 1 mm] C2b: [0 to 999999999 / 55800000 / 1 mm] |
Sets the PM yield of the fusing unit (Rotations). | ||
009 | Web (%) | [0 to 255 / 92 / 1 %] |
Sets the PM yield (%) of the web unit. | ||
021 | Day Threshold: PCD | [1 to 30 / 15 / 1 days] |
Adjusts the threshold day for the near end for the PCD. | ||
022 | Day Threshold: Transfer Unit | [1 to 30 / 15 / 1 days] |
Adjusts the threshold day for the near end for the transfer unit. | ||
023 | Day Threshold: Fusing Unit | [1 to 30 / 15 / 1 days] |
Adjusts the threshold day for the near end for the fusing unit. |
System SP Tables-7
7953 | Operation Env Log | |
001 | T<10 | [0 to 99999999 / 0 / 1 mm] |
Displays the PCU rotation distance in the environment: T<10°C | ||
002 | 10<=T<=17 | [0 to 99999999 / 0 / 1 mm] |
Displays the PCU rotation distance in the environment: 10°C<=T<=17°C | ||
003 | 17<T<23 | [0 to 99999999 / 0 / 1 mm] |
Displays the PCU rotation distance in the environment: 17<=T<=23 | ||
004 | 23<=T<=27 | [0 to 99999999 / 0 / 1 mm] |
Displays the PCU rotation distance of the environment: 23<=T<=27 | ||
005 | 27<=T<=32 | [0 to 99999999 / 0 / 1 mm] |
Displays the PCU rotation distance of the environment: 27<=T<=32 | ||
006 | 32<T | [0 to 99999999 / 0 / 1 mm] |
Displays the PCU rotation distance of the environment: 32<T |
7954 | Env Log Clear |
Resets the environment logs (SP7953). |