HOME PAGE | < Previous | Contents | Next >

System SP Table-1


3. APPENDIX: SERVICE PROGRAM MODE TABLES

3.1 SYSTEM SP TABLE-1


Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

3.1.1 SP1-XXX: FEED



1001*

Leading Edge Registration:

Adjusts the leading edge registration by changing the registration clutch operation timing.

001

Tray: Plain


[–9 to 9/ 0 / 0.1 mm step]

002

Tray: Thick 1

003

Tray: Thick 2

004

By-pass: Plain

005

By-pass: Thick 1

006

By-pass: Thick 2

007

Duplex: Plain

008

Duplex: Thick 1

System SP Table-1




1002*

Side-to-Side Registration

Adjusts the side to side registration by changing the laser main scan start position for each mode.

001

By-pass


[–4 to 4/ 0 / 0.1 mm step]

002

Tray 1

003

Tray 2

004

Tray 3

005

Tray 4

006

LCT

007

Duplex




1003*

Registration Buckle Adjustment

Adjusts the paper feed motor timing. Paper feed motor timing determines the amount of paper buckle at Registration. (A "+" setting causes more buckling.)

001

Tray 1: Plain


[-9 to 5 / -4 / 1 mm step]

002

Tray 1: Thick 1

003

Tray 1: Thick 2

004

Tray 2, 3, 4: Plain

005

Tray 2, 3, 4: Thick1

006

Tray 2, 3, 4: Thick2

007

By-pass: Plain


[-9 to 5 / -2 /1 mm step]

008

By-pass: Thick 1

009

By-pass: Thick 2

010

Duplex: Plain

[-9 to 5 / -4 / 1 mm step]

011

Duplex: Thick 1

[-9 to 5 / -3 / 1 mm step]

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Table-1


012

LCT: Plain


[-9 to 5 / -4 / 1 mm step]

013

LCT: Thick1

014

LCT: Thick2




1007*

By-pass Paper Size Detection

Controls paper size detection for the by-pass feed table.

001

Detection Timing

[-15 to 15 / 0 / 5 mm step]


002


LG Detection

[0 to 1 / 0 / 1]

0: LT SEF, 1: LG




1103*

Fusing Idling

Switches fusing idling on/off. When on, printing will not start until enough time has elapsed so the hot roller can reach optimum temperature. This ensures even heat on the hot roller.

Switch on if fusing on the 1st and 2nd copies is incomplete (this may occur if the room is cold.). You must switch SP1103-1 ON before you set the fusing interval with SP1103-2.

001

Enable Fusing Idling

0 = Off, 1 = On

002

Interval

[0 to 60 / 30 / 1 sec.]


003


Idling Time at Every Job

Sets the machine to fusing idling only for 30 sec. for every job (when the original is set on the ARDF, when the ARDF cover is opened, etc.) and the fusing unit has reached the reload temperature (optimum temperature for operation).

[0 to 30 / 0 / 1 sec.]

0: No idling done before a job.

System SP Table-1




1104*

Fusing Temperature Control

On-Off/Phase

Selects the fusing temperature control method. After changing this setting, be sure to turn the machine off and on again with the main power switch to enable the new setting.

[0 to 1 / 0 / 1]

0: Normal (ON/OFF control). Allows full application from ac power supply to bring the hot roller up to the target fusing temperature then shuts off.

Determines the on-time from the present temperature (detected by the thermistor on the hot roller) and the temperature of 1 cycle before.

1: Phase (hysterisis) control. Sets the upper and lower limits for the temperature; at the lower temperature the fusing lamp is on and at the higher temperature the fusing lamp is off.

Change this setting to "0" only if the user has excessive electrical noise or interference on the power supply line. Such interference can cause voltage to drop when power is applied using the ON/OFF control method.

Interference can be caused by the general poor quality of the power supply lines, or if the machine is sharing a power supply with other electrical devices such as fluorescent lights. Before changing this setting, make sure that the machine is connected to a power supply not shared by other electrical equipment.

Selecting Phase control ("1") could cause the fusing temperature control board to emit low pitched noise




1105*

Fusing Temperature Adjustment

Allows adjustment of the hot roller temperature at the center and ends of the roller for the quality or thickness of the paper. The hot roller in this machine has two fusing lamps: one heats the center of the roller, the other heats both ends. Each fusing lamp can be adjusted separately.

The "re-load temperature" is the "print ready temperature". When the fusing temperature exceeds this setting, the machine can operate. Do not set up a re-load temperature (Re-load Temp. = Fusing. Temp – SP Value.) that is higher than the SP1-105-2 setting.

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Table-1



001


Roller Center

C1b/C1.5b: [100 to 170 / 140 / 1 deg]

C1c/C1.5c: [100 to 170 / 150 / 1 deg]

Adjusts the fusing temperature at the center of the hot roller.


002


Roller Ends

C1b/C1.5b: [100 to 170 / 145 / 1 deg]

C1c/C1.5c: [100 to 170 / 155 / 1 deg]

Adjusts the fusing temperature at the ends of the hot roller.


003

Re-load Temp. Minus: Roller Center

[0 to 60 / 0 / 1 deg]

Sets the reload temperature for the center of the hot roller. This setting depends on the target temperature.

Reload temp. = Target Temp – This SP Setting


Do not set a temperature that is higher than the setting for SP1105 1 (Roller Center: Trays)


004

Re-load Temp. Minus: Roller Ends

[0 to 60 / 0 / 1 deg]

Sets the reload temperature for the ends of the hot roller. This setting depends on the target temperature.

Reload temp. = Target Temp – This SP Setting


Do not set a temperature that is higher than the setting for SP1105 2 (Roller Ends: Trays)

005 to

022

The following SPs adjust the fusing temperature at the center or ends of the hot roller for each paper type.


005


Roller Center: M-Thick

C1b/C1.5b: [100 to 170 / 145 / 1 deg]

C1c/C1.5c: [100 to 170 / 155 / 1 deg]


006


Roller Ends: M-Thick

C1b/C1.5b: [100 to 170 / 150 / 1 deg]

C1c/C1.5c: [100 to 170 / 160 / 1 deg]

007

Roller Center: Thick 1


[100 to 170 / 130 / 1 deg]

008

Roller Ends: Thick 1

009

Roller Center: Thick 2


[100 to 170 / 150/ 1 deg]

010

Roller Ends: Thick 2

System SP Table-1



011


Roller Center: Thin

C1b/C1.5b: [100 to 170 / 130 / 1 deg]

C1c/C1.5c: [100 to 170 / 140 / 1 deg]


012


Roller Ends: Thin

C1b/C1.5b: [100 to 170 / 135 / 1 deg]

C1c/C1.5c: [100 to 170 / 145 / 1 deg]

013

Roller Center: OHP: Plain

[100 to 170 / 150/ 1 deg]

014

Roller Ends: OHP: Plain


[100 to 170 / 155/ 1 deg]

015

Roller Center: OHP: Thick

016

Roller Ends: OHP: Thick

[100 to 170 / 160/ 1 deg]


017


Roller Center: Special 1

C1b/C1.5b: [100 to 170 / 140 / 1 deg]

C1c/C1.5c: [100 to 170 / 150 / 1 deg]


018


Roller Ends: Special 1

C1b/C1.5b: [100 to 170 / 145 / 1 deg]

C1c/C1.5c: [100 to 170 / 155 / 1 deg]


019


Roller Center: Special 2

C1b/C1.5b: [100 to 170 / 140 / 1 deg]

C1c/C1.5c: [100 to 170 / 150 / 1 deg]


020


Roller Ends: Special 2

C1b/C1.5b: [100 to 170 / 145 / 1 deg]

C1c/C1.5c: [100 to 170 / 155 / 1 deg]


021


Roller Center: Special 3

C1b/C1.5b: [100 to 170 / 140 / 1 deg]

C1c/C1.5c: [100 to 170 / 150 / 1 deg]


022


Roller Ends: Special 3

C1b/C1.5b: [100 to 170 / 145 / 1 deg]

C1c/C1.5c: [100 to 170 / 155 / 1 deg]

023

Feed Waiting: Plain

Turns the feed waiting mode on or off for each paper type.

[0 to 1 / 0 / 1] 0=Off, 1=On

The paper waits at the registration roller until the fusing temperature reaches the prescribed temperature (adjustable with SP1105-028 to -37).

If you enable this feature, also set SP 1105-38 to a convenient value for the customer.

024

Feed Waiting: M-Thick

025

Feed Waiting: Thick 1

026

Feed Waiting: Thick 2


027


Feed Waiting: Thin

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Table-1


028

Feed Wait: Center Minus: Plain


Adjusts the offset value for each re-load temperature to exit the feed waiting mode.

[0 to 60 / 0 / 1 deg]

029

Feed Wait: Ends Minus: Plain

030

Feed Wait: Center Minus: M-Thick

031

Feed Wait: Ends Minus: M-Thick

032

Feed Wait: Center Minus: Thick 1

033

Feed Wait: Ends Minus: Thick 1

034

Feed Wait: Center Minus: Thick 2

035

Feed Wait: Ends Minus: Thick 2

036

Feed Wait: Center Minus: Thin

037

Feed Wait: Ends Minus: Thin


038


Feed Waiting: Maximum Time

Sets the maximum feed waiting time. [0 to 30 / 0 / 1 sec]

The paper is fed when the time specified with this SP has passed even though the fusing temperature has not reached the prescribed temperature.

0: Disabled.



1106

Fusing Temperature Display

001

Roller Center

Displays the temperature of the fusing unit.

[-20 to 250 / 0 / 1 deg]


002


Roller Ends

003

Machine Inside at Power On

Displays the temperature inside the machine.

[-20 to 250 / 0 / 1 deg]


004


Machine Inside

System SP Table-1




1109*

Fusing Nip Band Check

Checks the fusing nip band.

001

Execution



002

Idling Rotation Time

[0 to 120 / 60 / 1 sec]

Specifies the fusing rotation time before executing SP1109-001.


003

Pre-Idling Time

[5 to 30 / 10 / 1 sec]

Specifies the time that the paper stops in the fusing unit for measuring the nip.




1159

Fusing Jam Detection

SC Code Display


[0 to 1 / 0 / 1] 0:OFF, 1:ON

This SP setting determines whether SC559 is issued after three paper late jams occur in the fusing unit. After this SP code is turned on, a counter monitors the number of paper late jams that occur in the fusing unit. After the 3rd occurrence of a fusing jam, SC559 is issued and the machine cannot be used until the service technician releases the error.

Switching the machine off/on does not reset this jam counter. The counter is reset after the cause of the jam has been removed and a sheet of paper successfully passes the fusing exit sensor.

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Table-1




1801*

Motor Speed Adjustment

Adjusts the speeds of each motor. Each step decreases or increases motor speed in 0.05% increments

Regist: Registration motor, Feed: Feed motor,

Duplex: Duplex/By-pass motor, Inverter: Duplex inverter motor, Exit: Paper exit motor, Bridge: Bridge unit drive motor,

OpcMot: Drum motor, TransferMot: Transfer/Development Motor, FusingMot: Fusing motor,

DevPuddleMot: Development Paddle motor

001

Regist: 90: Thick 2


[-2 to 2 / 0.4 / 0.05 %]

002

Regist: 154: Thick 1

003

Regist: 180: Plain

004

Regist: 230: Plain

005

Feed: 90: Thick 2


[-2 to 2 / -0.4 / 0.05 %]

006

Feed: 154: Thick 1

007

Feed: 180: Plain


[-2 to 2 / -1 / 0.05 %]

008

Feed: 230: Plain

009

Duplex_CW: 90: Thick 2


[-4 to 4 / 0.4 / 0.1 %]

010

Duplex_CW: 154: Thick 1

011

Duplex_CW: 180: Plain


[-4 to 4 / -2.3 / 0.1 %]

012

Duplex_CW: 230: Plain

013

Duplex_CCW: 90: Thick 2


[-4 to 4 / 0.4 / 0.1 %]

014

Duplex_CCW: 154: Thick 1

015

Duplex_CCW: 180: Plain


[-4 to 4 / -2.3 / 0.1 %]

016

Duplex_CCW: 230: Plain

017

Inverter_CW: 90: Thick 2


[-4 to 4 / 0 / 0.1 %]

018

Inverter_CW: 154: Thick 1

System SP Table-1


019

Inverter_CW: 180: Plain


020

Inverter_CW: 230: Plain

021

Inverter_CCW: 90: Thick 2

022

Inverter_CCW: 154: Thick 1

023

Inverter_CCW: 180: Plain

024

Inverter_CCW: 230: Plain

025

Exit_CW: 90: Thick 2

026

Exit_CW: 154: Thick 1

027

Exit_CW: 180: Plain

028

Exit_CW: 230: Plain

029

Bridge: 90: Thick 2

030

Bridge: 154: Thick 1

031

Bridge: 180: Plain

032

Bridge: 230: Plain

033

OpcMot:90


[-4 to 4 / 0 / 0.01 %]

034

OpcMot:154

035

OpcMot:180

036

OpcMot:230

037

TransferMot:90

038

TransferMot:154

039

TransferMot:180

040

TransferMot:230

041

FusingMot:90

042

FusingMot:154

043

FusingMot:180

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Table-1


044

FusingMot:230


045

DevPuddleMot

[-4 to 4 / 0 / 0.1 %]



1902

Cleaning Web Setting


001

Web Consumption

[0 to 120 / 0 / 1 %]

Displays the consumed amount of the web roll.


002


Web Motor Interval

C1b/C1.5b: [3 to 130 / 8.4 / 0.1 sec]

C1c/C1.5c: [3 to 130 / 6.7 / 0.1 sec]

Adjusts the interval for web motor rotation.


003

Web Motor Time

[0.3 to 10 / 4.2 / 0.1 sec]

Adjusts the rotation time of the web motor.


004


Web Near End Setting

C1b/C1.5b: EU [0 to 100 / 90 / 1 %]

C1b/C1.5b: ASIA/NA [0 to 100 / 92 / 1 %]

C1c/C1.5c: EU [0 to 100 / 90 / 1 %]

C1c/C1.5c: ASIA/NA [0 to 100 / 92 / 1 %]

Adjusts the threshold for web near end.


005

Web Motor Interval: Thick 1

[3 to 130 / 11.2 / 0.1 sec]

Adjusts the interval for web motor rotation (thick 1).


006

Web Motor Interval: Thick 2

[3 to 130 / 16.8 / 0.1 sec]

Adjusts the interval for web motor rotation (thick 2).


007

Paper Interval Time

[0 to 10 / 5 / 1 sec]

Adjusts the threshold for paper feeding. When the time between trailing edge detection and leading edge detection is within the value of this setting, the machine determines that the paper is still being fed.


008

Web Motor Setting: Web End

[0 to 60 / 27 / 1 sec]

Adjusts the motor rotation time after the web end.

009

Web Motor Rotation: Power On

[0 to 10 / 2 / 1 times]

System SP Table-1



Adjusts the number of web motor rotations at the re-load state.


010

Web Motor Interval: Pre-idle

[0 to 30 / 5 / 1 sec]

Adjusts the motor waiting time after the fusing motor idling.


011

Web Motor Rotation: Pre-idle

[0 to 10 / 2 / 1 times]

Adjusts the number of web motor rotations at the fusing idling state.



1903

Cleaning Web Setting


001

Total Paper Counter

[0 to 999999999 / 0 / 1 sec]

Displays the total paper feeding time.


002

Total Web Motor Drive Time

[0 to 999999999 / 0 / 1 sec]

Displays the total time of web motor rotation.



1907

Paper Feed Timing Adj. (DFU)

001

Feed Solenoid ON: Plain


[-10 to 40 / 0 / 2.5 mm]

002

Feed Solenoid ON: Thick

003

Feed Solenoid OFF: Plain


[-10 to 10 / 0 / 1 mm]

004

Feed Solenoid OFF: Thick

005

Feed Clutch ON: Plain

006

Feed Clutch ON: Thick

007

Stop Position before Inverter

008

Stop Position after Inverter

009

Re-Feed Stop Position

010

By-pass Solenoid OFF

[0 to 40 / 0 / 1 mm]

011

By-pass Solenoid ON

[0 to 1 / 1 / 1 mm]

012

By-pass Feed Clutch ON

[-10 to 10 / 0 / 1 mm]

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Table-1


013

Exit Roller: Shift: 180


014

Exit Roller: Shift: 230

015

Exit: Junction Solenoid ON

016

Exit: Junction Solenoid OFF

017

Bridge: Junction Solenoid ON

018

Bridge: Junction Solenoid OFF

019

1-Bin: Junction Solenoid ON

020

1-Bin: Junction Solenoid OFF

021

Shift Motor ON

[-1 to 1 / 0 / 0.1 mm]



1908

Paper Bank Feed Timing Adj (DFU)

001

Feed Clutch ON: Plain


[-10 to 10 / 0 / 1 mm]

002

Feed Clutch ON: Thick

System SP Table-1




1916

CPM Down Setting

When this machine gets a sequence of coping/printing jobs, the machine uses CPM down mode to prevent the fusing temperature from becoming too low.

001

Temp.: Plain


Adjusts the thresholds for each environmental condition (between Low and Medium).

[10 to 23 / 17 / 1 deg]

002

Temp.: M-Thick

003

Temp.: Thick 1

004

Temp.: Thick 2

005

Temp.: Thin

006

ON/OFF: Low: Plain


Turns on or off the CPM down setting for each paper type and ambient temperature.

[0 to 1 / 0 / 1 ]

0= Off, 1= On

007

ON/OFF: Low: M-Thick

008

ON/OFF: Low: Thick 1

009

ON/OFF: Low: Thick 2

010

ON/OFF: Low: Thin

011

ON/OFF: Medium: Plain

012

ON/OFF: Medium: M-Thick

013

ON/OFF: Medium:: Thick 1

014

ON/OFF: Medium: Thick 2

015

ON/OFF: Medium: Thin

016

Waiting Time: Low: Plain


Adjusts the threshold time to enter the CPM down mode.

[0 to 180 / 60 / 1 sec]

The machine determines whether the CPM down mode is activated or not after the time specified with these SPs has passed.

017

Waiting Time: Low: M-Thick

018

Waiting Time: Low: Thick 1

019

Waiting Time: Low: Thick 2

020

Waiting Time: Low: Thin

021

Waiting Time: Medium: Plain

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

Appendix: Service Program Mode Tables

System SP Table-1


022

Waiting Time: Medium: M-Thick


023

Waiting Time: Medium: Thick 1

024

Waiting Time: Medium: Thick 2

025

Waiting Time: Medium: Thin

026

Temp.: Low: Plain


Adjusts the threshold temperature of the fusing unit to enter the CPM down mode.

[100 to 200 / 120 / 1 deg]

If the temperature of the fusing unit is less than the temperature specified with these SPs, the machine changes the CPM (adjustable with SP1916-36 to -45).

027

Temp.: Low: Plain

028

Temp.: Low: Thick 1

029

Temp.: Low: Thick 2

030

Temp.: Low: Thin

031

Temp.: Medium: Plain

032

Temp.: Medium: M-Thick

033

Temp.: Medium: Thick 1

034

Temp.: Medium: Thick 2

035

Temp.: Medium: Thin


036


CPM: Low: Plain

Adjusts the CPM in the CPM down mode.

C1b/C1.5b: [20 to 35 / 35 / 5 cpm]

C1c/C1.5c: [20 to 45 / 45 / 5 cpm]


037


CPM: Low: M-Thick

Adjusts the CPM in the CPM down mode.

C1b/C1.5b: [20 to 35 / 35 / 5 cpm]

C1c/C1.5c: [20 to 45 / 45 / 5 cpm]


038


CPM: Low: Thick 1

Adjusts the CPM in the CPM down mode.

C1b/C1.5b: [5 to 15 / 15 / 5 cpm]

C1c/C1.5c: [5 to 25 / 25 / 5 cpm]


039


CPM: Low: Thick 2

Adjusts the CPM in the CPM down mode.

[5 to 15 / 15 / 5 cpm]

System SP Table-1


040

CPM: Low: Thin

Adjusts the CPM in the CPM down mode.

C1b/C1.5b: [20 to 35 / 35 / 5 cpm]

C1c/C1.5c: [30 to 45 / 45 / 5 cpm]

041

CPM: Medium: Plain

042

CPM: Medium: M-Thick


043


CPM: Medium: Thick 1

Adjusts the CPM in the CPM down mode.

C1b/C1.5b: [5 to 15 / 15 / 5 cpm]

C1c/C1.5c: [5 to 25 / 25 / 5 cpm]


044


CPM: Medium: Thick 2

Adjusts the CPM in the CPM down mode.

[5 to 15 / 15 / 5 cpm]


045


CPM: Medium: Thin

Adjusts the CPM in the CPM down mode.

C1b/C1.5b: [20 to 35 / 35 / 5 cpm]

C1c/C1.5c: [30 to 45 / 45 / 5 cpm]



1930

OnOff Time Adjust


001

On Time Adjust

[0 to 100 / 40 / 10 msec]

Adjusts the Off-On interval of the transfer belt contact motor. ("On" means that the transfer belt is in contact with the drum.)


002

Off Time Adjust

[0 to 100 / 20 / 10 msec]

Adjusts the On-Off interval of the transfer belt contact motor. ("Off" means that the transfer belt is away from the drum.)




1950

Tray Lock at Jam

[0 or 1 / 0 / 1 ] 0= OFF, 1= ON

Not used

 

SP1-XXX: FEED