Reinstallation
Explain to the customer that the following information stored on the HDD is lost when the HDD is replaced: document server documents, fixed stamps, document server address book
The address book and document server documents (if needed) must be input again.
4.15.3 CONTROLLER BOARD
The battery on the control board can explode if replaced incorrectly.
Dispose of the old battery in accordance with the instructions.
Before Replacing the Controller Board in the Model without HDD
When you replace the controller board in a model without a HDD, address book data can be copied from an old controller board to a new controller board using an SD card.
Copy the address book data to an SD card from the flash ROM on the controller board with
SP5846-051 if possible.
Replacement Procedure
1. Controller unit p.4-95)
2. HDD unit (if it has been installed.) p.4-96)
3. Controller cover [A] x 2)
Electrical Components
Replacement and Adjustment
Replacement and Adjustment
Replacement and Adjustment
4. Controller right bracket [A] x 5)
5. Controller board assembly [A] x 4, connector caps)