HOME PAGE | < Previous | Contents | Next >

Power Supply Control


3.2 POWER SUPPLY CONTROL


3.2.1 ENERGY-SAVE RECOVERY OPERATION

An Android screen is different from a conventional screen (standard screen) in the method of recovery from energy-saving mode.


Key

Android control unit

Standard control unit


HOME

Perform energy-save recovery, and display home screen.

(Equivalent to standard control unit [Energy-save] key)


Does not recover.

Status check

Perform energy-save recovery, and display status confirmation screen.

Same left


Energy-save


No key

Perform energy-save recovery, and display priority application screen.

* During recovery from low power mode, display application screen before shift.


LCD touch

Perform energy-save recovery, and display status confirmation screen. (Equivalent to standard control unit [Energy-save] key)


Does not recover.


Returns

Perform energy-save recovery, and display status confirmation screen. (Equivalent to standard control unit [Energy-save] key)


No corresponding key


MENU

Perform energy-save recovery, and display status confirmation screen. (Equivalent to standard control unit [Energy-save] key)


No corresponding key


STOP

Perform energy-save recovery, and display status confirmation screen. (Equivalent to standard control unit [Energy-save] key).

(Equivalent to standard control unit [Energy-save] key).


Does not recover.

Login/logout

No key

Does not recover.

 

ENERGY-SAVE RECOVERY OPERATIONSCREEN STARTUP MODESPECIAL SHUTDOWN