HOME PAGE | < Previous | Contents | Next >

Main SP Tables-3


2.5 MAIN SP TABLES-3


SP Mode Tables

SP Mode Tables

SP Mode Tables

2.5.1 SP3-XXX (PROCESS)


3011

[Manual ProCon :Exe]


001


Normal ProCon


ENG

[0 or 1 / 0 / 1/step] [Execute]

Executes Pro-Con.


002


Density Adjustment


ENG

[0 or 1 / 0 / 1/step] [Execute]

Executes toner density adjusting Pro-Con.


003


ACC RunTime ProCon


ENG

[0 or 1 / 0 / 1/step] [Execute]

Executes pre-ACC Pro-Con.


004


Full MUSIC


ENG

[0 or 1 / 0 / 1/step] [Execute]

Executes Pro-Con / full MUSIC.


005


Normal MUSIC


ENG

[0 or 1 / 0 / 1/step] [Execute]

Executes Pro-Con / normal MUSIC.




3012

[ProCon OK?]

2 digits per color from left, in the order of YMCK

*Refer to below for execution result content.


001

History:Last(Front)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays latest Pro-Con execution result.


002

History:Last 2(Front)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for the time before last.

Main SP Tables-3



003

History:Last 3(Front)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 3 times before.


004

History:Last 4(Front)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 4 times before.


005

History:Last 5(Front)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 5 times before.


006

History:Last 6(Front)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 6 times before.


007

History:Last 7(Front)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 7 times before.


008

History:Last 8(Front)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 8 times before.


009

History:Last 9(Front)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 9 times before.


010

History:Last 10(Front)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 10 times before.


011

History:Last(Center)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays latest Pro-Con execution result.


012

History:Last 2(Center)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 2 times before.


013

History:Last 3(Center)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 3 times before.


014

History:Last 4(Center)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 4 times before.


015

History:Last 5(Center)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 5 times before.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



016

History:Last 6(Center)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 6 times before.


017

History:Last 7(Center)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 7 times before.


018

History:Last 8(Center)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 8 times before.


019

History:Last 9(Center)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 9 times before.


020

History:Last 10(Center)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 10 times before.


021

History:Last(Rear)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays latest Pro-Con execution result.


022

History:Last 2(Rear)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for the time before last.


023

History:Last 3(Rear)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 3 times before.


024

History:Last 4(Rear)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 4 times before.


025

History:Last 5(Rear)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 5 times before.


026

History:Last 6(Rear)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 6 times before.


027

History:Last 7(Rear)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 7 times before.


028

History:Last 8(Rear)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 8 times before.

Main SP Tables-3



029

History:Last 9(Rear)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 9 times before.


030

History:Last 10(Rear)

*ENG

[0 to 99999999 / 0 / 1/step]

Displays Pro-Con execution result for 10 times before.

*SP3-012 Display result detail


Category

Code

Result name

Description


00 and lager


00


Not executed

Factory default setting(SP default)

10 and lager Result(Normal)


11


Succeed


-


20 and lager ID Sensor


21


ID Sensor Vsg adjust error

Out of range from Vsg=4.0±x.x[V/step]

22

ID Sensor LED Adjust error

Ifsg>Max


23

ID Sensor Output error(Positive reflect)


Vsg_reg<Min(Max)


24

ID Sensor output error(Diffusion reflect)


Vsg_dif<Min(Max)


25

ID Sensor offset Voltage error(Positive reflect)


Voffset_reg>Max


26

ID Sensor offset Voltage error(Diffusion reflect)


Voffset_dif>Max


45 and lager

ID Pattern detect

45

ID Pattern extract error

Can not detect ID Pattern

50

Vmin_Bk/K2 error(Max)

K:Vmin_Bk / CMY:K2>Max

51

Vmin_Bk/K2 error(Min)

K:Vmin_Bk / CMY:K2<Min

52

K5 error(Max)

K5>Max

53

K5 error(Min)

K5<Min


54

K5 calculated approximate point error

K5 calculated approximate point <Min

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3




55

Develop gamma error(Max)


Develop gamma >Max


56

Develop gamma error(Min)


Develop gamma <Min


57

Start developing voltage:Vk error(Max)

Start developing voltage:Vk>Max


58

Start developing voltage:Vk error(Min)

Start developing voltage:Vk<Min


59


Not enough valid data

Adhesion amount data for develop gamma calculation point is under 2


60 and lager Potential adjust

61

LD won’t light

P patter is not written.

62

Residual potential:Vr error

Vr>Max


63

Electrified potential:Vd adjust error

Vd can not be adjusted in target range.


64

Exposure potential:Vpl adjust error

Vpl can not be adjusted in target range


90 and lager Result(End)


90


Potential not adjust

Potential control method is set as [0:FIX]


99


Kill

Kill by door open, power off, error.

(Set when execute.)


 Execute result sample (In order of YMCK from left)

 Factory default(SP default):[00,00,00,00]

 Starting adjust:[99,99,99,99]

 Fail Vsg adjust(Y):[21,99,99,99]

 Error of Develop gamma Max(C):[99,99,55,99]

 Succeed:[11,11,11,11]

Main SP Tables-3




3014

[IBACC OK?]

Displays latest IBACC execution result.

001

History:Last

*ENG


[0 to 9999 / 0 / 1/step]

002

History:Last 2

*ENG

003

History:Last 3

*ENG

004

History:Last 4

*ENG

005

History:Last 5

*ENG

006

History:Last 6

*ENG

007

History:Last 7

*ENG

008

History:Last 8

*ENG

009

History:Last 9

*ENG

010

History:Last 10

*ENG



3030

[Init TD Sensor :Exe]


001


Execute: ALL


ENG

[0 or 1 / 0 / 1/step] [Execute]

Executes TD sensor initial setting for all colors.


002


Execute: Col


ENG

[0 or 1 / 0 / 1/step] [Execute]

Executes TD sensor initial setting only for chromatic 3 colors.


003


Execute: K


ENG

[0 or 1 / 0 / 1/step] [Execute]

Executes TD sensor initial setting for only (K).


004


Execute: C


ENG

[0 or 1 / 0 / 1/step] [Execute]

Executes TD sensor initial setting for only (C).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



005


Execute: M


ENG

[0 or 1 / 0 / 1/step] [Execute]

Executes TD sensor initial setting for only (M).


006


Execute: Y


ENG

[0 or 1 / 0 / 1/step] [Execute]

Executes TD sensor initial setting for only (Y).


020

Agitatiton Time

*ENG

[0 to 200 / 30 / 1sec/step]

Sets developing powder stirring time for when TD sensor's setting is in initial.


021

Initial TC

*ENG

[1.0 to 15.0 / 7.0 / 0.1wt%/step]

Sets toner density for initial chemical.


031

Vt Target:K

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Sets Vt target value (K) for when TD sensor's setting is in initial.


032

Vt Target:C

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Sets Vt target value (C) for when TD sensor's setting is in initial.


033

Vt Target:M

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Sets Vt target value (M) for when TD sensor's setting is in initial.


034

Vt Target:Y

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Sets Vt target value (M) for when TD sensor's setting is in initial.


041

Vt Target Corr:K

*ENG

[0.00 to 2.55 / 0.00 / 0.01V/step]

Sets metachronic correcting amount (K) for when TD sensor's setting is in initial.


042

Vt Target Corr:C

*ENG

[0.00 to 2.55 / 0.00 / 0.01V/step]

Sets metachronic correcting amount (C) for when TD sensor's setting is in initial.


043

Vt Target Corr:M

*ENG

[0.00 to 2.55 / 0.00 / 0.01V/step]

Sets metachronic correcting amount (M) for when TD sensor's setting is in initial.

Main SP Tables-3




044

Vt Target Corr:Y

*ENG

[0.00 to 2.55 / 0.00 / 0.01V/step]

Sets metachronic correcting amount (Y) for when TD sensor's setting is in initial.



3031

[TD Sens Init OK?]


001

From Left:YMCK

ENG

[0 to 9999 / 0 / 1/step]

Displays execution result of TD sensor initial setting.



3050

[Force Tnr Supply :Exe]


001


Execute: ALL


ENG

[0 or 1 / 0 / 1/step] [Execute]

Forcedly supply toner (all colors)


002


Execute: Col


ENG

[0 or 1 / 0 / 1/step] [Execute]

Forcedly supply toner (only CMY)


003


Execute: K


ENG

[0 or 1 / 0 / 1/step] [Execute]

Forcedly supply toner (only K)


004


Execute: C


ENG

[0 or 1 / 0 / 1/step] [Execute]

Forcedly supply toner (only C)


005


Execute: M


ENG

[0 or 1 / 0 / 1/step] [Execute]

Forcedly supply toner (only M)


006


Execute: Y


ENG

[0 or 1 / 0 / 1/step] [Execute]

Forcedly supply toner (only Y)

3050

[Force Tnr Supply :Exe]

021

Supply Quantity:K

*ENG

[0.0 to 5.0 / 0.5 / 0.1wt%/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



Sets the amount [wt%/step] to supply toner (K) with Force toner supply.


022

Supply Quantity:C

*ENG

[0.0 to 5.0 / 0.5 / 0.1wt%/step]

Sets the amount [wt%/step] to supply toner (C) with Force toner supply.


023

Supply Quantity:M

*ENG

[0.0 to 5.0 / 0.5 / 0.1wt%/step]

Sets the amount [wt%/step] to supply toner (M) with Force toner supply.


024

Supply Quantity:Y

*ENG

[0.0 to 5.0 / 0.5 / 0.1wt%/step]

Sets the amount [wt%/step] to supply toner (Y) with Force toner supply.


031

ON Time

*ENG

[10 to 1000 / 200 / 1msec/step]

Sets supply ON time for 1time of force toner supplying process routine.


032

OFF Time

*ENG

[0 to 1000 / 100 / 1msec/step]

Sets supply OFF time for 1time of force toner supplying process routine.


033

RepeatCount

*ENG

[0 to 255 / 8 / 1times/step]

Sets repeating times for 1time of force toner supplying process routine.




3072

[T Sensor: Check]

Executes testing mode to test TD sensor's output (Vt) without stating up the engine.


001


Execute Check


ENG

[0 or 1 / 0 / 1/step] [Execute]




3073

[T Sensor Measurement Value:]

Displays output test value of TD sensor.

001

Vt:K

*ENG


[0.00 to 5.50 / 0.00 / 0.01V/step]

002

Vt:C

*ENG

003

Vt:M

*ENG

004

Vt:Y

*ENG

Main SP Tables-3


3100

[Tonner End Detection: Set]


001

ON/OFF

*ENG

[0 or 1 / 0 / 1/step]

Whether to decide NE/TE. 0: Enable

1: Disable


002

NE Detection

*ENG

[0 or 1 / 0 / 1/step]

NE decision method.

0: Counter & Toner End Sensor 1: Toner End Sensor Only




3101

[Toner Status :Disp]


Displays remaining toner.


001

K

ENG





[0 to 10 / 10 / 1/step]

002

C

ENG

10: Full

003

M

ENG

1: Near end

0: Toner end

004

Y

ENG




3102

[Toner Remain:Disp]

Remaining toner calculated form motor running time.


001


Bottle Motor: Bk


*ENG

[0.000 to 700.000 / 560.000 / 0.001g]

002

Bottle Motor: C

*ENG


[0.000 to 700.000 / 440.000 / 0.001g]

003

Bottle Motor: M

*ENG

004

Bottle Motor: Y

*ENG


3102

[Toner Remain:Disp]

Remaining toner calculated from imaging size.


011


Pixel: Bk


*ENG

[0.000 to 700.000 / 560.000 / 0.001g]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


012

Pixel: C

*ENG


[0.000 to 700.000 / 440.000 / 0.001g]

013

Pixel: M

*ENG

014

Pixel: Y

*ENG


3102

[Toner Remaining: Display]

Filler content of new bottle.

021

Fill Amount: Bk

*ENG

[0 to 600 / 560 / 1g/step]

022

Fill Amount: C

*ENG


[0 to 600 / 440 / 1g/step]

023

Fill Amount: M

*ENG

024

Fill Amount: Y

*ENG


3102

[Toner Remain:Disp]

Consumption amount of toner.


031

Pixel: Toner Consumption x 2: C


*ENG


[0.000 to 1000.000 / 0.000 / 0.001g]


032

Pixel: Toner Consumption x 2: Bk


*ENG


033

Pixel: Toner Consumption x 2: M


*ENG


034

Pixel: Toner Consumption x 2: Y


*ENG


041

Drive Motor: Toner Consumption x 1: Bk


*ENG


042

Drive Motor: Toner Consumption x 1: C


*ENG


043

Drive Motor: Toner Consumption x 1: M


*ENG


044

Drive Motor: Toner Consumption x 1: Y


*ENG



3103

[Bottle Off Time]

Main SP Tables-3



-

001

Bk

*ENG


[0 to 4294967295 / 0 / 1/step]

002

C

*ENG

003

M

*ENG

004

Y

*ENG




3104

[Flag: Display]

Sets flag when replacing toner bottle.

001

NE Toner: Bk

*ENG


[0 or 1 / 0 / 1/step]

002

NE Toner: C

*ENG

003

NE Toner: M

*ENG

004

NE Toner: Y

*ENG


3104

[Flag: Display]

Sets Flag when Vt ends.

011

Vt end:Bk

*ENG


[0 or 1 / 0 / 1/step]

012

Vt end:C

*ENG

013

Vt end:M

*ENG

014

Vt end:Y

*ENG




3110

[Near End Thresh]

-

001

Bk

*ENG

[0 to 500 / 65 / 1g/step]

002

C

*ENG


[0 to 500 / 45 / 1g/step]

003

M

*ENG

004

Y

*ENG

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



3111

[Pixel NE: M/A]

-


001


Bk


*ENG

[0 to 1000 / 411 / 0.001mg/cm2/step]


002


C


*ENG

[0 to 1000 / 444 / 0.001mg/cm2/step]


003


M


*ENG

[0 to 1000 / 500 / 0.001mg/cm2/step]


004


Y


*ENG

[0 to 1000 / 444 / 0.001mg/cm2/step]




3120

[TE Sn Detect Thresh]

-

001

Bk

*ENG


[0 to 100 / 50 / 1%/step]

002

C

*ENG

003

M

*ENG

004

Y

*ENG




3121

[TE Counter: Disp]

No toner decision times from end sensor.

001

Bk

*ENG


[0 to 99 / 0 / 1times/step]

002

C

*ENG

003

M

*ENG

004

Y

*ENG




3122

[TE Sn NE Thresh]

-

001

Bk

*ENG

[0 to 99 / 80 / 1times/step]

Main SP Tables-3


002

C

*ENG


003

M

*ENG

004

Y

*ENG



3131

[Vt TE Thresh]


001

Delta Vt Thresh

*ENG

[0.00 to 5.00 / 0.50 / 0.01V/step]

Threshold to start adding delta Vt after NE.


002

Delta Vt Sum Thresh

*ENG

[0 to 99 / 10 / 1V/step]

Threshold to decide TE after NE.


011

Delta Vt Thresh BF NE

*ENG

[0.00 to 5.00 / 0.50 / 0.01V/step]

Threshold to start adding delta Vt before NE.


012

Delta Vt Sum Thresh BF NE

*ENG

[0 to 99 / 10 / 1V/step]

Threshold to decide TE before NE.




3132

[Delta Vt Sum]

Added value of delta Vt.

001

Bk

*ENG


[0.00 to 99.00 / 0.00 / 0.01V/step]

002

C

*ENG

003

M

*ENG

004

Y

*ENG



3133

[TE Detect :Set]


001

Set Sheets(Min)

*ENG

[0 to 50 / 10 / 1sheet/step]

Sets min. assured sheets to display toner end after toner near end is fixed.


002

Set Sheets(Max)

*ENG

[0 to 5000 / 1000 / 1sheet/step]

Sets max. assured sheets to display toner end after toner near end is fixed.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



3133

[TE Detect :Set]

Displays the amount of sheets printed after toner near end is fixed.

011

Page Cnt:K

*ENG


[0 to 5000 / 0 / 1sheet/step]

012

Page Cnt:C

*ENG

013

Page Cnt:M

*ENG

014

Page Cnt:Y

*ENG


3133

[TE Detect :Set]

Sets dimension (cm2) in terms of blotted out A4 sized sheet to decide as toner end after near toner end is fixed.

021

Set Pxl Cnt

*ENG

[0 to 1000000 / 7000 / 1cm2/step]


3133

[TE Detect :Set]

Displays the amount used with dimension (cm2) in terms of blotted out.

031

Pxl Cnt:K

*ENG


[0 to 1000000 / 0 / 1cm2/step]

032

Pxl Cnt:C

*ENG

033

Pxl Cnt:M

*ENG

034

Pxl Cnt:Y

*ENG



3150

[TE Sensor :Set]


001

SamplingCount

*ENG

[4 to 20 / 10 / 1counts/step]

Sets arrangement size of TE sensor.


002

Judge:p

*ENG

[0.2 to 1.0 / 0.8 / 0.1/step]

Sets threshold for to decide toner existing..


3150

[T TE Sensor :Set]

Percentage for "No remaining toner" of storing arrangement.

003

result:K

*ENG


[0.0 to 0.1 / 0.5 / 0.1/step]

004

result:C

*ENG

Main SP Tables-3


005

result:M

*ENG


006

result:Y

*ENG




3160

[Bottle Drive :Set]

Select bottle driving method.


001


Bottle Drive System


*ENG

[0 or 1 / 0 / 1/step]

0: TE Sensor Control

1: TonerSupplyMotor Track Control




3161

[Bottle Drive :Set]

-

001

Drive ON Time:K



[0 to 2000 / 900 / 100msec/step]

002

Drive ON Time:C


003

Drive ON Time:M


004

Drive ON Time:Y





3162

[Bottle Drive :Set]

-

001

Drive OFF Time:K



[0 to 5000 / 100 / 100msec/step]

002

Drive OFF Time:C


003

Drive OFF Time:M


004

Drive OFF Time:Y





3165

[Hopper Drive :Set]

-

001

Speed Adjustment:K



[-58 to 50 / 18 / 1%/step]

002

Speed Adjustment:C


SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


003

Speed Adjustment:M


[-58 to 50 / 40 / 1%/step]

004

Speed Adjustment:Y


[-58 to 50 / 18 / 1%/step]




3200

[TnrDensity]

Displays toner density (wt%).

001

K

*ENG


[0 to 25.5 / 0 / 0.1 wt%/step]

002

C

*ENG

003

M

*ENG

004

Y

*ENG




3201

[TnrDensity]

Sets min./max. density (wt%) for toner density controlling range.

001

Upper TC

*ENG

[1.0 to 15.0 / 9.0 / 0.1wt%/step]

002

Lower TC

*ENG

[1.0 to 15.0 / 2.0 / 0.1wt%/step]




3205

[TD.Sens Sensitivity]

Displays TD sensor sensitivity HL calculated from test value of HST density control (SP3-711 to 714-***)

001

HL:K

*ENG


[0.200 to 1.000 / 0.350 /

0.001-V/wt%/step]

002

HL:C

*ENG

003

HL:M

*ENG

004

HL:Y

*ENG


3205

[TD.Sens Sensitivity]

Displays TD sensor sensitivity HM calculated from test value of HST density control (SP3-711 to 714-***)

011

HM:K

*ENG


[0.200 to 1.000 / 0.350 /

0.001-V/wt%/step]

012

HM:C

*ENG

Main SP Tables-3


013

HM:M

*ENG


014

HM:Y

*ENG


3205

[TD.Sens Sensitivity]

Displays TD sensor sensitivity ML calculated from test value of HST density control (SP3-711 to 714-***)

021

ML:K

*ENG


[0.200 to 1.000 / 0.350 /

0.001-V/wt%/step]

022

ML:C

*ENG

023

ML:M

*ENG

024

ML:Y

*ENG

3205

[TD.Sens Sensitivity]


031


Upper Limit


*ENG

[0.200 to 0.500 / 0.440 /

0.001-V/wt%/step]

Sets max. sensitivity for to calculate TD sensor sensitivity.


032


Lower Limit


*ENG

[0.150 to 0.500 / 0.180 /

0.001-V/wt%/step]

Sets min. sensitivity for to calculate TD sensor sensitivity.


033

TC Between H-M:K

*ENG

[1.00 to 10.00 / 4.50 / 0.01wt%

Sets HM interval as TC of K for to calculate TD sensor sensitivity.


034

TC Between M-L:K

*ENG

[1.00 to 10.00 / 4.40 / 0.01wt%

Sets ML interval as TC of K for to calculate TD sensor sensitivity.


043

TC Between H-M:Col

*ENG

[1.00 to 10.00 / 4.20 / 0.01wt%

Sets HM interval as TC of CMY for to calculate TD sensor sensitivity.


044

TC Between H-M:Col

*ENG

[1.00 to 10.00 / 4.40 / 0.01wt%

Sets ML interval as TC of CMY for to calculate TD sensor sensitivity.




3210

[TD.Sens:Vt :Disp]

Displays latest T sensor output.

SP Mode Tables

SP Mode Tables

SP Mode Tables

001

Current: K

*ENG


[0.00 to 5.50 / 0.00 / 0.01V/step]

002

Current: C

*ENG

003

Current: M

*ENG

004

Current: Y

*ENG

001

Current: K

*ENG


[0.00 to 5.50 / 0.00 / 0.01V/step]

002

Current: C

*ENG

003

Current: M

*ENG

004

Current: Y

*ENG

001

Current: K

*ENG


[0.00 to 5.50 / 0.00 / 0.01V/step]

002

Current: C

*ENG

003

Current: M

*ENG

004

Current: Y

*ENG

3211

[Vt Limits Err :Disp]


002

Upper Threshold

*ENG

[0.00 to 5.00 / 4.70 / 0.01V/step]

Sets Vt upper limit threshold to decide as Vt upper limit error.


003

Thresh Num of UpperCounter

*ENG

[0 to 255 / 20 / 1times/step]

Sets the number of times excessing Vt upper limit to set off SC360 to 363 (Vt upper limit error).


004

Lower Threshold

*ENG

[0.00 to 5.00 / 0.50 / 0.01V/step]

Sets Vt upper limit threshold to decide as Vt lower limit error.


005

Threshold Num of LowerCounter


*ENG


[0 to 255 / 10 / 1times/step]

Sets the number of times excessing Vt lower limit to set off SC365 to 363 (Vt upper limit error).


3211

[Vt Limits Err :Disp]

Counts times of Vt(K/C/M/Y) excessing Vt upper limit threshol

011

Upper Counter: Bk

*ENG


[0 to 255 / 0 / 1times/step]

012

Upper Counter: C

*ENG

013

Upper Counter: M

*ENG

014

Upper Counter: Y

*ENG


3211

[Vt Limits Err :Disp]

Counts times of Vt(K/C/M/Y) excessing Vt lower limit threshold.

021

Lower Counter: Bk

*ENG


[0 to 255 / 0 / 1times/step]

022

Lower Counter: C

*ENG

3211

[Vt Limits Err :Disp]


002

Upper Threshold

*ENG

[0.00 to 5.00 / 4.70 / 0.01V/step]

Sets Vt upper limit threshold to decide as Vt upper limit error.


003

Thresh Num of UpperCounter

*ENG

[0 to 255 / 20 / 1times/step]

Sets the number of times excessing Vt upper limit to set off SC360 to 363 (Vt upper limit error).


004

Lower Threshold

*ENG

[0.00 to 5.00 / 0.50 / 0.01V/step]

Sets Vt upper limit threshold to decide as Vt lower limit error.


005

Threshold Num of LowerCounter


*ENG


[0 to 255 / 10 / 1times/step]

Sets the number of times excessing Vt lower limit to set off SC365 to 363 (Vt upper limit error).


3211

[Vt Limits Err :Disp]

Counts times of Vt(K/C/M/Y) excessing Vt upper limit threshol

011

Upper Counter: Bk

*ENG


[0 to 255 / 0 / 1times/step]

012

Upper Counter: C

*ENG

013

Upper Counter: M

*ENG

014

Upper Counter: Y

*ENG


3211

[Vt Limits Err :Disp]

Counts times of Vt(K/C/M/Y) excessing Vt lower limit threshold.

021

Lower Counter: Bk

*ENG


[0 to 255 / 0 / 1times/step]

022

Lower Counter: C

*ENG

3211

[Vt Limits Err :Disp]


002

Upper Threshold

*ENG

[0.00 to 5.00 / 4.70 / 0.01V/step]

Sets Vt upper limit threshold to decide as Vt upper limit error.


003

Thresh Num of UpperCounter

*ENG

[0 to 255 / 20 / 1times/step]

Sets the number of times excessing Vt upper limit to set off SC360 to 363 (Vt upper limit error).


004

Lower Threshold

*ENG

[0.00 to 5.00 / 0.50 / 0.01V/step]

Sets Vt upper limit threshold to decide as Vt lower limit error.


005

Threshold Num of LowerCounter


*ENG


[0 to 255 / 10 / 1times/step]

Sets the number of times excessing Vt lower limit to set off SC365 to 363 (Vt upper limit error).


3211

[Vt Limits Err :Disp]

Counts times of Vt(K/C/M/Y) excessing Vt upper limit threshol

011

Upper Counter: Bk

*ENG


[0 to 255 / 0 / 1times/step]

012

Upper Counter: C

*ENG

013

Upper Counter: M

*ENG

014

Upper Counter: Y

*ENG


3211

[Vt Limits Err :Disp]

Counts times of Vt(K/C/M/Y) excessing Vt lower limit threshold.

021

Lower Counter: Bk

*ENG


[0 to 255 / 0 / 1times/step]

022

Lower Counter: C

*ENG

Main SP Tables-3

Main SP Tables-3


023

Lower Counter: M

*ENG


024

Lower Counter: Y

*ENG




3212

[Vt Shift :Set]

Sets middle speed correction amount for correcting Vt shift caused by line speed.


001


Mid Spd:K


*ENG

[0.00 to 2.55 / D146, D147: 8 D148:

0 D149, D150: 3 / 0.01V/step]

002

Mid Spd:C

*ENG


[0.00 to 2.55 / 0.07 / 0.01V/step]

003

Mid Spd:M

*ENG

004

Mid Spd:Y

*ENG


3212

[Vt Shift :Set]

Sets low speed correction amount for correcting Vt shift caused by line speed.

011

Low Spd:K

*ENG


[0.00 to 2.55 / 0.14 / 0.01V/step]

012

Low Spd:C

*ENG

013

Low Spd:M

*ENG

014

Low Spd:Y

*ENG


3212

[Vt Shift :Set]

Sets ON/OFF TC correction amount of Vt shift.


101


ON/OFF


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1:ON


3212

[Vt Shift :Set]

Displays TC correction amount of Vt shift.

111

TC Mid Spd:K

*ENG


[-0.50 to 0.50 / 0.00 / 0.01V/step]

112

TC Mid Spd:C

*ENG

113

TC Mid Spd:M

*ENG

SP Mode Tables

SP Mode Tables

SP Mode Tables

114

TC Mid Spd:Y

*ENG


121

TC Low Spd:K

*ENG

122

TC Low Spd:C

*ENG

123

TC Low Spd:M

*ENG

124

TC Low Spd:Y

*ENG

114

TC Mid Spd:Y

*ENG


121

TC Low Spd:K

*ENG

122

TC Low Spd:C

*ENG

123

TC Low Spd:M

*ENG

124

TC Low Spd:Y

*ENG

114

TC Mid Spd:Y

*ENG


121

TC Low Spd:K

*ENG

122

TC Low Spd:C

*ENG

123

TC Low Spd:M

*ENG

124

TC Low Spd:Y

*ENG


3214

[Vt Save :Set]

Saves Vt based to image area ratio.

001

Coverage Thresh

*ENG

[0 to 100 / 20 / 1%/step]


3214

[Vt Save :Set]

Saves Vt based to image area ratio.

001

Coverage Thresh

*ENG

[0 to 100 / 20 / 1%/step]


3214

[Vt Save :Set]

Saves Vt based to image area ratio.

001

Coverage Thresh

*ENG

[0 to 100 / 20 / 1%/step]

Main SP Tables-3



3218

[Vt Err Flag :Disp]


001

UppErr Flag: K

*ENG

[0 or 1 / 0 / 1/step]

Sets flag "1" when Vt(K) excesses Vt upper limit error threshold (SP3-221-002) even 1 time.


002

UppErr Flag: C

*ENG

[0 or 1 / 0 / 1/step]

Sets flag "1" when Vt(C) excesses Vt upper limit error threshold (SP3-221-002) even 1 time.


003

UppErr Flag: M

*ENG

[0 or 1 / 0 / 1/step]

Sets flag "1" when Vt(M) excesses Vt upper limit error threshold (SP3-221-002) even 1 time.


004

UppErr Flag: Y

*ENG

[0 or 1 / 0 / 1/step]

Sets flag "1" when Vt(Y) excesses Vt upper limit error threshold (SP3-221-002) even 1 time.


011

LowErr Flag: K

*ENG

[0 or 1 / 0 / 1/step]

Sets flag "1" when Vt(K) excesses Vt lower limit error threshold (SP3-221-004) even 1 time.

012

LowErr Flag: C

*ENG

[0 or 1 / 0 / 1/step]

Main SP Tables-3



Sets flag "1" when Vt(C) excesses Vt lower limit error threshold (SP3-221-004) even 1 time.


013

LowErr Flag: M

*ENG

[0 or 1 / 0 / 1/step]

Sets flag "1" when Vt(M) excesses Vt lower limit error threshold (SP3-221-004) even 1 time.


014

LowErr Flag: Y

*ENG

[0 or 1 / 0 / 1/step]

Sets flag "1" when Vt(Y) excesses Vt lower limit error threshold (SP3-221-004) even 1 time.




3219

[TD.Sens:Vt':Disp]

Displays Vt before Vt shift correction.

001

Vt'0Current: K

ENG


[0.00 to 5.00 / 0.00 / 0.01V/step]

002

Vt'0Current: C

ENG

003

Vt'0Current: M

ENG

004

Vt'0Current: Y

ENG

011

Vt'1Current: K

ENG

012

Vt'1Current: C

ENG

013

Vt'1Current: M

ENG

014

Vt'1Current: Y

ENG

021

Vt'2Current: K

ENG

022

Vt'2Current: C

ENG

023

Vt'2Current: M

ENG

024

Vt'2Current: Y

ENG



3220

[Vtcnt :Disp/Set]


001

Current: K

*ENG

[2.00 to 5.00 / 3.60 / 0.01V/step]

Displays/Sets Current TD Sensor Control Voltage (K).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



002

Current: C

*ENG

[2.00 to 5.00 / 3.75 / 0.01V/step]

Displays/Sets Current TD Sensor Control Voltage (C).


003

Current: M

*ENG

[2.00 to 5.00 / 3.75 / 0.01V/step]

Displays/Sets Current TD Sensor Control Voltage (M).


004

Current: Y

*ENG

[2.00 to 5.00 / 3.75 / 0.01V/step]

Displays/Sets Current TD Sensor Control Voltage (Y).


011

Initial: K

*ENG

[2.00 to 5.00 / 3.60 / 0.01V/step]

Displays control voltage of TD sensor when default setting TD sensor.


012

Initial: C

*ENG

[2.00 to 5.00 / 3.75 / 0.01V/step]

Displays control voltage of TD sensor when default setting TD sensor.


013

Initial: M

*ENG

[2.00 to 5.00 / 3.75 / 0.01V/step]

Displays control voltage of TD sensor when default setting TD sensor.


014

Initial: Y

*ENG

[2.00 to 5.00 / 3.75 / 0.01V/step]

Displays control voltage of TD sensor when default setting TD sensor.



3230

[Vtref :Disp/Set]


001

Current: K

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Displays / Sets current target value of TD sensor's output voltage: Vtref (K).


002

Current: C

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Displays / Sets current target value of TD sensor's output voltage: Vtref (C).


003

Current: M

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Displays / Sets current target value of TD sensor's output voltage: Vtref (M).


004

Current: Y

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Displays / Sets current target value of TD sensor's output voltage: Vtref (Y).

011

Initial: K

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Main SP Tables-3



Displays target value of TD sensor's (K) output voltage when executing TD sensor initial setting.


012

Initial: C

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Displays target value of TD sensor's (C) output voltage when executing TD sensor initial setting.


013

Initial: M

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Displays target value of TD sensor's (M) output voltage when executing TD sensor initial setting.


014

Initial: Y

*ENG

[0.00 to 5.00 / 2.50 / 0.01V/step]

Displays target value of TD sensor's (Y) output voltage when executing TD sensor initial setting.


3230

[Vtref :Disp/Set]

Displays pixel correction amount of Vtref correction by image area.

021

Pixel Correction: K

*ENG


[-5.00 to 5.50 / 0.00 / 0.01V/step]

022

Pixel Correction: C

*ENG

023

Pixel Correction: M

*ENG

024

Pixel Correction: Y

*ENG



3231

[Vtref Limits :Set]


001

Upper:K

*ENG

[0.00 to 5.00 / 4.00 / 0.01V/step]

Sets upper limit for target value of TD sensor's output voltage: Vtref (K).


002

Upper:C

*ENG

[0.00 to 5.00 / 4.00 / 0.01V/step]

Sets upper limit for target value of TD sensor's output voltage: Vtref (C).


003

Upper:M

*ENG

[0.00 to 5.00 / 4.00 / 0.01V/step]

Sets upper limit for target value of TD sensor's output voltage: Vtref (M).


004

Upper:Y

*ENG

[0.00 to 5.00 / 4.00 / 0.01V/step]

Sets upper limit for target value of TD sensor's output voltage: Vtref (Y).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



011

Lower:K

*ENG

[0.00 to 5.00 / 2.00 / 0.01V/step]

Sets lower limit for target value of TD sensor's output voltage: Vtref (K).


012

Lower:C

*ENG

[0.00 to 5.00 / 2.00 / 0.01V/step]

Sets lower limit for target value of TD sensor's output voltage: Vtref (C).


013

Lower:M

*ENG

[0.00 to 5.00 / 2.00 / 0.01V/step]

Sets lower limit for target value of TD sensor's output voltage: Vtref (M).


014

Lower:Y

*ENG

[0.00 to 5.00 / 2.00 / 0.01V/step]

Sets lower limit for target value of TD sensor's output voltage: Vtref (Y).



3232

[Vtref Correct:Pixel]


001


ON/OFF


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

Switches ON/OFF pixel Vtref correction.


3232

[Vtref Correct:Pixel]

Sets coefficient to decide Vtref correction value of Vtref correction by image area.

Vtref correction value: SP3-222-009 to 012 = calculated Vtref correction value small area coefficient (This SP)

How to use this SP: Vtref correction by image area.

011

Low Coverage Coef:K

*ENG


[0.0 to 5.0 / 1.0 / 0.1/step]

012

Low Coverage Coef:C

*ENG

013

Low Coverage Coef:M

*ENG

014

Low Coverage Coef:Y

*ENG

3232

[Vtref Correct:Pixel]

Main SP Tables-3



Sets coefficient to decide Vtref correction value of Vtref correction by image area.

Vtref correction value: SP3-222-009 to 012 = calculated Vtref correction value large area coefficient (This SP)

How to use this SP: Vtref correction by image area.

021

High Coverage Coeff:K

*ENG


[0.0 to 5.0 / 0.5 / 0.1/step]

022

High Coverage Coeff:C

*ENG

023

High Coverage Coeff:M

*ENG

024

High Coverage Coeff:Y

*ENG

3232

[Vtref Correct:Pixel]


040

Initial ProCon Thresh

*ENG

[0 to 255 / 100 / 1times/step]

Executes Pro-Con by setting a Pro-Con flag when image area cumulative average M (SP3-224-009 to 012) is larger than the specified value and then so deciding that large area images are continuing. When large area images are continuing, specified


041

High Coverage Thresh:H

*ENG

[0 to 100 / 100 / 1%/step]

How to use this SP: Refer to this SP when printing large area images.

When image area accumulate average M (SP3-224-009 to 012) is larger than this SP, judges that high area images are continuing, then set Pro-Con flag and,


050

ProCon Thresh

*ENG

[0 to 255 / 100 / 1times/step]

Executes Pro-Con by setting a Pro-Con flag when image area total average M (SP3-224-009 to 012) is larger than the specified value and then so deciding that large area images are continuing. When large area images are continuing, specified


060

Low Coverage Thresh

*ENG

[0.0 to 20.0 / 3.0 / 0.1%/step]

How to use this SP: Refer to this SP when printing small area images.

When image area accumulate average L (SP3-224-013 to 016) is less than this SP, judges that low high area images are continuing, then temporarily dis

3232

[Vtref Correct:Pixel]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



Switches to a mode able to call off Vtref lower limit (Upper limit of TC) by deciding small area images are continuing when image area cumulative average L (SP3-224-013 to 016) is small.

This SP

070

TC Upper Limit Correction

*ENG

[0.0 to 5.0 / 0.5 / 0.1wt%/step]

071

TC Upper Limit:Display:Bk

*ENG


[1.0 to 15.0 / 8.5 / 0.1wt%/step]

072

TC Upper Limit:Display:C

*ENG

073

TC Upper Limit:Display:M

*ENG

074

TC Upper Limit:Display:Y

*ENG



3233

[RTP Vtref Corr :Disp/Set]


001


ON/OFF


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

Controls ON/OFF the Vtref correction done based on RTP pattern deposit amount during print.


3233

[RTP Vtref Corr :Disp/Set]

Sets Vtref correction value (K/C/M/Y) when RTP pattern deposit amount goes over deposit amount threshold (upper/lower limit).

011

Corr Amt(+):K

*ENG


[0.00 to 1.00 / 0.03 / 0.01V/step]

012

Corr Amt(+):C

*ENG

013

Corr Amt(+):M

*ENG

014

Corr Amt(+):Y

*ENG

021

Corr Amt(-):K

*ENG

022

Corr Amt(-):C

*ENG

023

Corr Amt(-):M

*ENG

024

Corr Amt(-):Y

*ENG

3233

[RTP Vtref Corr :Disp/Set]

Main SP Tables-3



Sets upper/lower limit threshold (K/C/M/Y) of RTP deposit amount.


031


Corr Thresh:K


*ENG

[0.000 to 0.100 / 0.005 /

0.001mg/cm2/step]

032

Corr Thresh:C

*ENG


[0.000 to 0.100 / 0.010 /

0.001mg/cm2/step]

033

Corr Thresh:M

*ENG

034

Corr Thresh:Y

*ENG

3233

[RTP Vtref Corr :Disp/Set]


041

Vtavg Weight Coeff (H)

*ENG

[0 to 100 / 30 / 1%/step]

Sets the weight of Vtavg and Vtref used for Vtref Correction Standard Value when Paper Interval Adhesion Amount exceeds Adhesion Amount Threshold (Upper Limit).


051

Vtavg Weight Coeff (M)

*ENG

[0 to 100 / 0 / 1%/step]

Sets the weight of Vtavg and Vtref used for Vtref Correction Standard Value when Paper Interval Adhesion Amount exceeds Adhesion Amount Threshold (Lower Limit).


061

Vtavg Weight Coeff (L)

*ENG

[0 to 100 / 5 / 1%/step]

Sets the weight of Vtavg and Vtref used for Vtref Correction Standard Value when Paper Interval Adhesion Amount exceeds Adhesion Amount Threshold (Lower Limit).



3234

[Vtref Corr :Disp/Set]


001


ON/OFF


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

Controls ON/OFF Vtref correction of electric potential control.


3234

[Vtref Corr :Disp/Set]

Set when controlling to keep toner density low with electric potential based on develop gamma.

Means Vtref correction (+) side correction amount.

011

Corr Amt(+):K

*ENG

[0.00 to 1.00 / 0.00 / 0.01V/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


012

Corr Amt(+):C

*ENG


013

Corr Amt(+):M

*ENG

014

Corr Amt(+):Y

*ENG


3234

[Vtref Corr :Disp/Set]

Set when controlling to keep toner density low with electric potential based on develop gamma.

Means Vtref correction (-) side correction amount.

021

Corr Amt(-):K

*ENG


[0.00 to 1.00 / 0.00 / 0.01V/step]

022

Corr Amt(-):C

*ENG

023

Corr Amt(-):M

*ENG

024

Corr Amt(-):Y

*ENG

3234

[Vtref Corr :Disp/Set]


031

P Rank 1 Threshold

*ENG

[0.00 to 2.00 / 0.15 / 0.01/step]

Meaning the threshold for P_Rank decision formula below, to decide develop gamma is "High" or "Little High" then the develop gamma target value and develop gamma detection value's diff (delta gamma) among the Vtref correct execution conditions. (Unit:


032

P Rank 2 Threshold

*ENG

[0.00 to 2.00 / 0.05 / 0.01/step]

Meaning the threshold for P_Rank decision formula below, to decide develop gamma is "Little High" or "Fair" then the develop gamma target value and develop gamma detection value's diff (delta gamma) among the Vtref correct execution conditions. (Unit:


033

P Rank 3 Threshold

*ENG

[-2.00 to 0.00 / -0.05 / 0.01/step]

Meaning the threshold for P_Rank decision formula below, to decide develop gamma is "Little Low" or "Fair" then the develop gamma target value and develop gamma detection value's diff (delta gamma) among the Vtref correct execution conditions. (Unit:

034

P Rank 4 Threshold

*ENG

[-2.00 to 0.00 / -0.15 / 0.01/step]

Main SP Tables-3



Meaning the threshold for P_Rank decision formula below, to decide develop gamma is "Low" or "Little Low" then the develop gamma target value and develop gamma detection value's diff (delta gamma) among the Vtref correct execution conditions. (Unit:


041

T Rank 1 Threshold

*ENG

[-1.00 to 0.00 / -0.20 / 0.01V/step]

Threshold to decide toner density as "Deep" or "Fair" by Vt and Vtref's diff (delta Vt) among the Vtref correct execution conditions.


042

T Rank 2 Threshold

*ENG

[0.00 to 1.00 / 0.20 / 0.01V/step]

Threshold to decide toner density as "Thin" or "Fair" by Vt and Vtref's diff (delta Vt) among the Vtref correct execution conditions.


050

Correction Coefficient

*ENG

[1.0 to 5.0 / 2.0 / 0.1/step]

Sets correction coefficient for Vtref correction amount.




3250

[ImgArea :Disp]

Displays image area for the latest page.

001

ImgArea:K

*ENG


[0 to 9999 / 0 / 1cm2/step]

002

ImgArea:C

*ENG

003

ImgArea:M

*ENG

004

ImgArea:Y

*ENG



3251

[DotCoverage :Disp]


001

DotCoverage:K

*ENG

[0.00 to 100.00 / 0.00 / 0.01%/step]

Displays image area rate (K) for the latest page.


002

DotCoverage:C

*ENG

[0.00 to 100.00 / 0.00 / 0.01%/step]

Displays image area rate (C) for the latest page.


003

DotCoverage:M

*ENG

[0.00 to 100.00 / 0.00 / 0.01%/step]

Displays image area rate (M) for the latest page.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3




004

DotCoverage:Y

*ENG

[0.00 to 100.00 / 0.00 / 0.01%/step]

Displays image area rate (Y) for the latest page.


011

DC Avg.:S:K

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Displays image area rate cumulative average: S (K)


012

DC Avg.:S:C

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Displays image area rate cumulative average: S (C)


013

DC Avg.:S:M

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Displays image area rate cumulative average: S (M)


014

DC Avg.:S:Y

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Displays image area rate cumulative average: S (Y)


021

DC Avg.:M:K

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Displays image area rate cumulative average: M (K)


022

DC Avg.:M:C

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Displays image area rate cumulative average: M (C)


023

DC Avg.:M:M

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Displays image area rate cumulative average: M (M)


024

DC Avg.:M:Y

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Displays image area rate cumulative average: M (Y)


031

DC Avg.:L:K

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Displays image area rate cumulative average: L (K)


032

DC Avg.:L:C

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Displays image area rate cumulative average: L (C)


033

DC Avg.:L:M

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Displays image area rate cumulative average: L (M)

034

DC Avg.:L:Y

*ENG

[0.00 to 100.00 / 5.00 / 0.01%/step]

Main SP Tables-3



Displays image area rate cumulative average: L (Y)


041

TotalPage:S:Set

*ENG

[1 to 255 / 10 / 1sheet/step]

Sets cumulative sheets: S


042

TotalPage:M:Set

*ENG

[1 to 500 / 10 / 1sheet/step]

Sets cumulative sheets: M


043

TotalPage:L:Set

*ENG

[1 to 999 / 50 / 1sheet/step]

Sets cumulative sheets: L


051

TotalPage:S:Set

*ENG

[1 to 255 / 20 / 1sheet/step]

Sets cumulative sheets: S


052

TotalPage:M:Set

*ENG

[1 to 500 / 10 / 1sheet/step]

Sets cumulative sheets: M


053

TotalPage:S:Set

*ENG

[1 to 999 / 50 / 1sheet/step]

Sets cumulative sheets: L




3252

[AccumImgArea :Disp]

Displays cumulative image area.

001

ImgArea:K

*ENG


[0 to 65535 / 0 / 1cm^2/step]

002

ImgArea:C

*ENG

003

ImgArea:M

*ENG

004

ImgArea:Y

*ENG



3260

[Temperature/Humidity: Display]


001

Temperature

ENG

[-5.0 to 45.0 / 0.0 / 0.1deg]

Displays temperature of environment sensor output.


002

Relative Humidity

ENG

[0.0 to 100.0 / 0.0 / 0.1%RH/step]

Displays relative humidity of environment sensor output.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



003


Absolute Humidity


ENG

[0.00 to 100.00 / 0.00 /

0.01g/m3/step]

Displays absolute humidity of environment sensor output.



3300

[RTP Pattern :Disp]


001


M/A(Latest):K


*ENG

[0.000 to 1.000 / 0.000 /

0.001mg/cm2/step]

Displays latest RTP pattern sensor's deposit amount (K).


002


M/A(Latest):C


*ENG

[0.000 to 1.000 / 0.000 /

0.001mg/cm2/step]

Displays latest RTP pattern sensor's deposit amount (C).


003


M/A(Latest):M


*ENG

[0.000 to 1.000 / 0.000 /

0.001mg/cm2/step]

Displays latest RTP pattern sensor's deposit amount (M).


004


M/A(Latest):Y


*ENG

[0.000 to 1.000 / 0.000 /

0.001mg/cm2/step]

Displays latest RTP pattern sensor's deposit amount (Y).


011


M/A(Target):K


*ENG

[0.000 to 1.000 / 0.220 /

0.001mg/cm2/step]

Displays RTP pattern sensor's depositing target amount (K).


012


M/A(Target):C


*ENG

[0.000 to 1.000 / 0.400 /

0.001mg/cm2/step]

Displays RTP pattern sensor's depositing target amount (C).


013


M/A(Target):M


*ENG

[0.000 to 1.000 / 0.450 /

0.001mg/cm2/step]

Displays RTP pattern sensor's depositing target amount (M).


014


M/A(Target):Y


*ENG

[0.000 to 1.000 / 0.400 /

0.001mg/cm2/step]

Displays RTP pattern sensor's depositing target amount (Y).

Main SP Tables-3



3301

[RTP Pattern :Set]


001

Create Intrvl:BW

ENG

[0 to 200 / 10 / 1pages]

Sets creating interval (K) for RTP pattern.


002

Create Intrvl:FC

ENG

[0 to 200 / 10 / 1pages]

Sets creating interval (C) for RTP pattern.


011

Page Cnt:BW

*ENG

[0 to 200 / 0 / 1pages]

Displays sheets counter value (K) for RTP pattern.


012

Page Cnt:FC

*ENG

[0 to 200 / 0 / 1pages]

Displays sheets counter value (C) for RTP pattern.


021


M/A UppErr:K


ENG

[0.000 to 1.000 / 0.600 /

0.001mg/cm2/step]

Sets error decision threshold (K) for SC380 RTP patter error.


022


M/A UppErr:Col


ENG

[0.000 to 2.000 / 1.200 /

0.001mg/cm2/step]

Sets error decision threshold (CMY) for SC381 to SC383 RTP patter error.


023


M/A LowErr:K


ENG

[0.000 to 1.000 / 0.100 /

0.001mg/cm2/step]

Sets error decision threshold (K) for SC385 RTP patter error.


024


M/A LowErr:Col


ENG

[0.000 to 1.000 / 0.200 /

0.001mg/cm2/step]

Sets error decision threshold (CMY) for SC386 to SC388 RTP patter error.


031

Feed Cnt :Set

*ENG

[0 to 99999999 / 50000 / 1ms/step]

Totals up ON time of sub hopper feed clutch (Reset when toner end sensor detects toner).


041

Feed Cnt :K

*ENG

[0 to 99999999 / 0 / 1 ms/step]

Totals up ON time of sub hopper feed clutch (K).

042

Feed Cnt :C

*ENG

[0 to 99999999 / 0 / 1 ms/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



Totals up ON time of sub hopper feed clutch (C).


043

Feed Cnt :M

*ENG

[0 to 99999999 / 0 / 1 ms/step]

Totals up ON time of sub hopper feed clutch (M).


044

Feed Cnt :Y

*ENG

[0 to 99999999 / 0 / 1 ms/step]

Totals up ON time of sub hopper feed clutch (Y).v

051

Vsg Detect Intrvl


[0 to 200 / 10 / 1pages/step]

061

Vsg Page Cnt


[0 to 200 / 0 / 1pages/step]

070

LowErr Thresh


[0 to 99 / 3 / 1times/step]

071

LowErr Cnt:K



[0 to 99 / 0 / 1times/step]

072

LowErr Cnt:C


073

LowErr Cnt:M


074

LowErr Cnt:Y



081


M/A(RTP)_Std


*ENG

[0.000 to 1.000 / 0.220 /

0.001mg/cm2/step]

Sets standard deposit amount of RTP pattern deposit amount target value (K).


091


M/A Thresh_Upp:K


*ENG

[0.000 to 1.000 / 0.060 /

0.001mg/cm2/step]

Sets upper limit threshold of RTP pattern deposit amount target value (K).


092


M/A Thresh_Upp:C


*ENG

[0.000 to 1.000 / 0.050 /

0.001mg/cm2/step]

Sets upper limit threshold of RTP pattern deposit amount target value (C).


093


M/A Thresh_Upp:M


*ENG

[0.000 to 1.000 / 0.050 /

0.001mg/cm2/step]

Sets upper limit threshold of RTP pattern deposit amount target value (M).


094


M/A Thresh_Upp:Y


*ENG

[0.000 to 1.000 / 0.050 /

0.001mg/cm2/step]

Sets upper limit threshold of RTP pattern deposit amount target value (Y).

Main SP Tables-3



101


M/A Thresh_Low:K


*ENG

[0.000 to 1.000 / 0.050 /

0.001mg/cm2/step]

Sets lower limit threshold of RTP pattern deposit amount target value (K).


102


M/A Thresh_Low:C


*ENG

[0.000 to 1.000 / 0.100 /

0.001mg/cm2/step]

Sets lower limit threshold of RTP pattern deposit amount target value (C).


103


M/A Thresh_Low:M


*ENG

[0.000 to 1.000 / 0.100 /

0.001mg/cm2/step]

Sets lower limit threshold of RTP pattern deposit amount target value (M).


104


M/A Thresh_Low:Y


*ENG

[0.000 to 1.000 / 0.100 /

0.001mg/cm2/step]

Sets lower limit threshold of RTP pattern deposit amount target value (Y).


111

Weight Coeff:K

*ENG

[1 to 10 / 1 / 1/step]

Adds weight to leveling process of RTP pattern deposit amount target value (K).


112

Weight Coeff:Col

*ENG

[1 to 10 / 1 / 1/step]

Adds weight to leveling process of RTP pattern deposit amount target value (Col).




3310

[ID.Sens :Voffset]

Displays specular reflection light output voltage of ID sensor's LED OFF time.

001

Voffset reg (Front)

*ENG


[0.00 to 5.50 / 0.00 / 0.01V/step]

002

Voffset reg (Center)

*ENG

003

Voffset reg (Rear)

*ENG


3310

[ID.Sens :Voffset]

Displays diffuse reflection light output voltage of ID sensor's LED OFF time.

011

Voffset dif (Front)

*ENG


[0.00 to 5.50 / 0.00 / 0.01V/step]

012

Voffset dif (Center)

*ENG

013

Voffset dif (Rear)

*ENG

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



3310

[ID.Sens :Voffset]

Displays specular reflection light output voltage of TM_Front sensor's LED OFF time.


021

Voffset TM(Front)

*ENG

[0.00 to 5.50 / 0.00 / 0.01V/step]

Displays specular reflection light output voltage of TM_Front sensor's LED OFF time.


022

Voffset TM(Center)

*ENG

[0.00 to 5.50 / 0.00 / 0.01V/step]

Displays specular reflection light output voltage of TM_Center sensor's LED OFF tim


023

Voffset TM(Rear)

*ENG

[0.00 to 5.50 / 0.00 / 0.01V/step]

Displays specular reflection light output voltage of TM_Rear sensor's LED OFF time.




3311

[ID.Sens :Vmin]

Displays Black Vmin output of tone pattern.

001

Vmin_K(Front)

*ENG


[0.000 to 5.000 / 0.000 /

0.001V/step]

002

Vmin_K(Center)

*ENG

003

Vmin_K(Rear)

*ENG




3312

[ID.Sens :Vct]

Factory adjust value of ID sensor.

001

Vct_reg(Front)

*ENG


[0.000 to 5.000 / 0.000 /

0.001V/step]

002

Vct_reg(Center)

*ENG

003

Vct_reg(Rear)

*ENG

011

Vct_dif(Front)

*ENG

012

Vct_dif(Center)

*ENG

013

Vct_dif(Rear)

*ENG

Main SP Tables-3


3320

[Vsg Adj: Execute]


001


P Sensor


ENG

[0 or 1 / 0 / 1/step] [Execute]

Adjusts Vsg.


012

Voffset Threshold

*ENG

[0.00 to 5.00 / 1.00 / 0.01V/step]

Sets upper limit threshold of Voffset error.


013

Vsg Upper Threshold

*ENG

[0.00 to 5.00 / 4.50 / 0.01V/step]

Sets upper limit threshold of Vsg adjust error.


014

Vsg Lower Threshold

*ENG

[0.00 to 5.00 / 3.50 / 0.01V/step]

Sets lower limit threshold of Vsg adjust error.


015

Ifsg UpperLimit

*ENG

[0.0 to 50.0 / 30.0 / 0.1mA/step]

Sets error decision threshold of SC382 (If upper limit error).


020

Interval :Set

*ENG

[0 to 2000 / 0 / 1page/step]

Sets Vsg adjusting execute page interval to be decided after or during printing.


 Will be executed when Pro-Con or MUSIC decides necessity. (Won't work alone)


021

Page Cnt

*ENG

[0 to 2000 / 0 / 1page/step]

Displays Page counter for Vsg execute decision.


031

Vsg Error Counter (Front)

*ENG

[0 to 99 / 0 / 1times/step]

Counts Vsg error.


032

Vsg Error Counter (Center)

*ENG

[0 to 99 / 0 / 1times/step]

Counts Vsg error.


033

Vsg Error Counter (Rear)

*ENG

[0 to 99 / 0 / 1times/step]

Counts Vsg error.



3321

[Adjusted Vsg]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



Displays specular reflection light output of belt background area adjusted Vsg.

001

Vsg reg (Front)

*ENG


[0.00 to 5.50 / 0.00 / 0.01V/step]

002

Vsg reg (Center)

*ENG

003

Vsg reg (Rear)

*ENG


3321

[Adjusted Vsg]

Displays diffuse reflection light output of belt background area adjusted Vsg.

011

Vsg dif (Front)

*ENG


[0.00 to 5.50 / 0.00 / 0.01V/step]

012

Vsg dif (Center)

*ENG

013

Vsg dif (Rear)

*ENG


021

Vsg reg(BW)

*ENG

[0.00 to 5.50 / 0.00 / 0.01V/step]

Displays specular reflection light output of belt background area adjusted Vs


031

Vsg dif(BW)

*ENG

[0.00 to 5.50 / 0.00 / 0.01V/step]

Displays diffuse reflection light output of belt background area adjusted Vsg.


041

Vsg TM(Front)

*ENG

[0.00 to 5.50 / 0.00 / 0.01V/step]

Displays specular reflection light output of belt background area adjusted Vsg. (TM_Front sensor)


042

Vsg TM(Center)

*ENG

[0.00 to 5.50 / 0.00 / 0.01V/step]

Displays specular reflection light output of belt background area adjusted Vsg. (TM_Center sensor)


043

Vsg TM(Rear)

*ENG

[0.00 to 5.50 / 0.00 / 0.01V/step]

Displays specular reflection light output of belt background area adjusted Vsg. (TM_Rear sensor)




3322

[Adjusted Ifsg]

LED ampere value for RTP.

001

Ifsg RTP (Front)

*ENG


[0.0 to 50.0 / 10.0 / 0.1mA/step]

002

Ifsg RTP (Center)

*ENG

Main SP Tables-3


003

Ifsg RTP (Rear)

*ENG



3322

[Adjusted Ifsg]

LED ampere value min. value.

011

Ifsg Min (Front)

*ENG


[0.0 to 50.0 / 27.0 / 0.1mA/step]

012

Ifsg Min (Center)

*ENG

013

Ifsg Min (Rear)

*ENG


3322

[Adjusted Ifsg]

LED ampere value for electric potential control;, MUSIC.

021

Ifsg: TM(Front)

*ENG


[0.0 to 50.0 / 10.0 / 0.1mA/step]

022

Ifsg: TM(Center)

*ENG

023

Ifsg: TM(Rear)

*ENG




3323

[Vsg Adj OK?]

Displays Vsg adjustment result (SP assign for have compatibility with unification model sires)

 Left digit: TM/P sensor (R)

 Right digit: TM/P sensor (L)

Displays result by each sensor from left in R, then L order.

Code

Result

detail

0

Did not EXEC.

(SP default)

1

Succeed

-


2

ID sensor proofread error

Out of range from Vsg= Vsg_reg(target value)±x.x[V/step]

3

Offset voltage error

Voffset_reg>Max. or Voffset_dif>Max.

4

LED Ampere Max. error.

Ifsg>Max.

5

ID sensor output error.

Vsg< Vsg_reg(error)

9

Kill

Kill by error of door open, power off.

001

Latest

*ENG

[0 to 999 / 0 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


002

Latest 2

*ENG


003

Latest 3

*ENG

004

Latest 4

*ENG

005

Latest 5

*ENG

006

Latest 6

*ENG

007

Latest 7

*ENG

008

Latest 8

*ENG

009

Latest 9

*ENG

010

Latest 10

*ENG



3330

[ID.Sens Coef :Disp]


001


K2(Latest) (Front)


*ENG

[0.0000 to 5.0000 / 0.0000 /

0.0001/step]

Displays latest value of ID sensor sensitivity correction coefficient: K2.


002


K2(Latest) (Center)


*ENG

[0.0000 to 5.0000 / 0.0000 /

0.0001/step]

Displays latest value of ID sensor sensitivity correction coefficient: K3.


003


K2(Latest) (Rear)


*ENG

[0.0000 to 5.0000 / 0.0000 /

0.0001/step]

Displays latest value of ID sensor sensitivity correction coefficient: K4.


011


K5(Latest) (Front)


*ENG

[0.0000 to 5.0000 / 1.2000 /

0.0001/step]

Displays latest value of ID sensor sensitivity correction coefficient: K5


012


K5(Latest) (Center)


*ENG

[0.0000 to 5.0000 / 1.2000 /

0.0001/step]

Displays latest value of ID sensor sensitivity correction coefficient: K6.


013


K5(Latest) (Rear)


*ENG

[0.0000 to 5.0000 / 1.2000 /

0.0001/step]

Main SP Tables-3



Displays latest value of ID sensor sensitivity correction coefficient: K7.




3331

[ID.Sens Coef :Set]

Assign (no need with Tomahawk) for having compatibility with unification model sires (Ap/At, Diana, Zeus).

001

K2: Upp Limit Corr

*ENG

[-0.20 to 0.40 / 0.17 / 0.01/step]

002

K2: Lwr Limit Corr

*ENG

[-0.40 to 0.20 / 0.03 / 0.01/step]

003

K2: Upp/Lwr Limit Coef1

*ENG

[0.00 to 1.00 / 0.00 / 0. 01]

3331

[ID.Sens Coef :Set]


004

Kn: Upper

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Sets upper limit valid range of standardization value for specular reflection used for calculating sensitivity correction: K5.


005

Kn: Lower

*ENG

[0.00 to 1.00 / 0.10 / 0.01/step]

Sets lower limit valid range of standardization value for specular reflection used for calculating sensitivity correction: K5


006

K5: Upper

*ENG

[0.00 to 10.00 / 6.00 / 0.01/step]

Sets upper limit value of calculated sensitivity correction coefficient: K5.


007

K5: Lower

*ENG

[0.00 to 1.00 / 0.50 / 0.01/step]

Sets lower limit value of calculated sensitivity correction coefficient: K5.


008

K5: Target Point

*ENG

[0.00 to 1.00 / 0.15 / 0.01/step]

Sets proofreading point (Kn) of sensitivity correction coefficient: K5.


009

K5: Target Voltage

*ENG

[0.00 to 5.00 / 1.63 / 0.01V/step]

Sets proofreading point (Kn) of sensitivity correction coefficient: K5.


012

Corrct Coef:C

*ENG

[0.500 to 1.500 / 1.000 / 0.001/step]

Sets color diff correction coefficient (C) of Delta Vsp_Dif_Dash.


013

Corrct Coef:M

*ENG

[0.500 to 1.500 / 0.996 / 0.001/step]

Sets color diff correction coefficient (M) of Delta Vsp_Dif_Dash.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



014

Corrct Coef:Y

*ENG

[0.500 to 1.500 / 1.111 / 0.001/step]

Sets color diff correction coefficient (Y) of Delta Vsp_Dif_Dash.




3332

[M/A Calculation]

Assign (no need with Tomahawk) for having compatibility with unification model sires (Ap/At, Diana, Zeus).

001

Corrct Coef:K

*ENG


[0.50 to 2.00 / 1.00 / 0.01/step]

002

Corrct Coef:C

*ENG

003

Corrct Coef:M

*ENG

004

Corrct Coef:Y

*ENG




3333

[ID.Sens TestVal:F]

Shipping test value of ID sensor. Factory inputs using process application. Service personal inputs when on the market.

001

K2: Check

*ENG

[0.000 to 1.000 / 0.516 / 0.001/step]

002

Diffuse Corr

*ENG

[0.75 to 1.35 / 1.00 / 0.01/step]

003

Vct_reg Check:Slope

*ENG

[0.0 to 200.0 / 0.0 / 0.1mV/mA]

004

Vct_reg Check:Xint

*ENG

[0.0 to 25.5 / 0.0 / 0.1mA/step]

005

Vct_dif Check:Slope

*ENG

[0.0 to 200.0 / 0.0 / 0.1mV/mA]

006

Vct_dif Check:Xint

*ENG

[0.0 to 25.5 / 0.0 / 0.1mA/step]




3334

[ID.Sens TestVal:C]

Shipping test value of ID sensor. Factory inputs using process application. Service personal inputs when on the market.

001

K2: Check

*ENG

[0.000 to 1.000 / 0.516 / 0.001/step]

002

Diffuse Corr

*ENG

[0.75 to 1.35 / 1.00 / 0.01/step]

003

Vct_reg Check:Slope

*ENG

[0.0 to 200.0 / 0.0 / 0.1mV/mA]

Main SP Tables-3


004

Vct_reg Check:Xint

*ENG

[0.0 to 25.5 / 0.0 / 0.1mA/step]

005

Vct_dif Check:Slope

*ENG

[0.0 to 200.0 / 0.0 / 0.1mV/mA]

006

Vct_dif Check:Xint

*ENG

[0.0 to 25.5 / 0.0 / 0.1mA/step]




3335

[ID.Sens TestVal:R]

Shipping test value of ID sensor. Factory inputs using process application. Service personal inputs when on the market.

001

K2: Check

*ENG

[0.000 to 1.000 / 0.516 / 0.001/step]

002

Diffuse Corr

*ENG

[0.75 to 1.35 / 1.00 / 0.01/step]

003

Vct_reg Check:Slope

*ENG

[0.0 to 200.0 / 0.0 / 0.1mV/mA/step]

004

Vct_reg Check:Xint

*ENG

[0.0 to 25.5 / 0.0 / 0.1mA/step]

005

Vct_dif Check:Slope

*ENG

[0.0 to 200.0 / 0.0 / 0.1mV/mA/step]

006

Vct_dif Check:Xint

*ENG

[0.0 to 25.5 / 0.0 / 0.1mA/step]




3400

[Toner Supply Type]


Selects toner supply method.


001

K

*ENG





[0 to 4 / 4 / 1/step]

002

C

*ENG

0: Fixed

003

M

*ENG

2: PID

4: DANC

004

Y

*ENG




3411

[Toner Supply Qty]

Displays latest value of supply amount calculated from toner supply amount computation formula.

001

K

ENG


[0.0 to 40000.0 / 0.0 / 0.1mg/step]

002

C

ENG

003

M

ENG

SP Mode Tables

SP Mode Tables

SP Mode Tables


3420

[DeveloperWeight]

Sets amount of developer weight.

001

Total_Weight:K

*ENG


[50 to 2000 / 380 / 1g/step]

002

Total_Weight:CMY

*ENG


3420

[DeveloperWeight]

Sets amount of developer weight.

001

Total_Weight:K

*ENG


[50 to 2000 / 380 / 1g/step]

002

Total_Weight:CMY

*ENG


3420

[DeveloperWeight]

Sets amount of developer weight.

001

Total_Weight:K

*ENG


[50 to 2000 / 380 / 1g/step]

002

Total_Weight:CMY

*ENG


3421

[TnrSplyAbility]

Sets toner supply ability from sub hopper to develop unit.

001

K

*ENG


[0.001 to 2.000 / 0.710 /

0.001mg/msec]

002

C

*ENG

003

M

*ENG

004

Y

*ENG


3421

[TnrSplyAbility]

Corrects supply ability based on supplying time per time unit.

011

TnrSplyAbilityCoef1

*ENG


[0.50 to 2.00 / 1.12 / 0.01/step]

012

TnrSplyAbilityCoef2

*ENG

013

TnrSplyAbilityCoef3

*ENG

[0.50 to 2.00 / 1.10 / 0.01/step]

014

TnrSplyAbilityCoef4

*ENG

[0.50 to 2.00 / 1.06 / 0.01/step]

015

TnrSplyAbilityCoef5

*ENG

[0.50 to 2.00 / 1.00 / 0.01/step]

016

TnrSplyAbilityCoef6

*ENG

[0.50 to 2.00 / 0.99 / 0.01/step]

017

TnrSplyAbilityCoef7

*ENG

[0.50 to 2.00 / 0.98 / 0.01/step]

018

TnrSplyAbilityCoef8

*ENG


[0.50 to 2.00 / 0.95 / 0.01/step]

019

TnrSplyAbilityCoef9

*ENG

020

TnrSplyAbilityCoef10

*ENG

021

unit time


[0 to 60000 / 3000 / 1msec/step]


3421

[TnrSplyAbility]

Sets toner supply ability from sub hopper to develop unit.

001

K

*ENG


[0.001 to 2.000 / 0.710 /

0.001mg/msec]

002

C

*ENG

003

M

*ENG

004

Y

*ENG


3421

[TnrSplyAbility]

Corrects supply ability based on supplying time per time unit.

011

TnrSplyAbilityCoef1

*ENG


[0.50 to 2.00 / 1.12 / 0.01/step]

012

TnrSplyAbilityCoef2

*ENG

013

TnrSplyAbilityCoef3

*ENG

[0.50 to 2.00 / 1.10 / 0.01/step]

014

TnrSplyAbilityCoef4

*ENG

[0.50 to 2.00 / 1.06 / 0.01/step]

015

TnrSplyAbilityCoef5

*ENG

[0.50 to 2.00 / 1.00 / 0.01/step]

016

TnrSplyAbilityCoef6

*ENG

[0.50 to 2.00 / 0.99 / 0.01/step]

017

TnrSplyAbilityCoef7

*ENG

[0.50 to 2.00 / 0.98 / 0.01/step]

018

TnrSplyAbilityCoef8

*ENG


[0.50 to 2.00 / 0.95 / 0.01/step]

019

TnrSplyAbilityCoef9

*ENG

020

TnrSplyAbilityCoef10

*ENG

021

unit time


[0 to 60000 / 3000 / 1msec/step]


3421

[TnrSplyAbility]

Sets toner supply ability from sub hopper to develop unit.

001

K

*ENG


[0.001 to 2.000 / 0.710 /

0.001mg/msec]

002

C

*ENG

003

M

*ENG

004

Y

*ENG


3421

[TnrSplyAbility]

Corrects supply ability based on supplying time per time unit.

011

TnrSplyAbilityCoef1

*ENG


[0.50 to 2.00 / 1.12 / 0.01/step]

012

TnrSplyAbilityCoef2

*ENG

013

TnrSplyAbilityCoef3

*ENG

[0.50 to 2.00 / 1.10 / 0.01/step]

014

TnrSplyAbilityCoef4

*ENG

[0.50 to 2.00 / 1.06 / 0.01/step]

015

TnrSplyAbilityCoef5

*ENG

[0.50 to 2.00 / 1.00 / 0.01/step]

016

TnrSplyAbilityCoef6

*ENG

[0.50 to 2.00 / 0.99 / 0.01/step]

017

TnrSplyAbilityCoef7

*ENG

[0.50 to 2.00 / 0.98 / 0.01/step]

018

TnrSplyAbilityCoef8

*ENG


[0.50 to 2.00 / 0.95 / 0.01/step]

019

TnrSplyAbilityCoef9

*ENG

020

TnrSplyAbilityCoef10

*ENG

021

unit time


[0 to 60000 / 3000 / 1msec/step]

Main SP Tables-3


004

Y

ENG


Main SP Tables-3



3421

[TnrSplyAbility]

Sets absolute humidity threshold 1 of supply ability correction.

031

AbsHum Threshold:1

*ENG

[0.0 to 65.0 / 6.0 / 0.1g/m3/step]

032

AbsHum Threshold:2

*ENG

[0.0 to 65.0 / 12.0 / 0.1g/m3/step]

033

AbsHum Threshold:3

*ENG

[0.0 to 65.0 / 24.0 / 0.1g/m3/step]


3421

[TnrSplyAbility]

Corrects supply ability based on absolute humidity.

041

Environ Coef1

*ENG


[0.50 to 2.00 / 1.00 / 0.01/step]

042

Environ Coef2

*ENG

043

Environ Coef3

*ENG

044

Environ Coef4

*ENG




3422

[Tnr Supply Limits :Set]

Sets max. toner supplying rate.

001

Max Supply Rate:K

*ENG


[0 to 255 / 100 / 1%/step]

002

Max Supply Rate:C

*ENG

003

Max Supply Rate:M

*ENG

004

Max Supply Rate:Y

*ENG


3422

[Tnr Supply Limits :Set]

Sets min. supplying time.

011

Min Supply Time: K

*ENG


[0 to 255 / 100 / 1msec/step]

012

Min Supply Time: C

*ENG

013

Min Supply Time: M

*ENG

014

Min Supply Time: Y

*ENG

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3




3423

[TnrSplyCarryOver :Disp]

Sets toner supplying rate for fixed amount supplying mode.

001

Carry Over:K

*ENG


[0 to 10000 / 0 / 1msec/step]

002

Carry Over:C

*ENG

003

Carry Over:M

*ENG

004

Carry Over:Y

*ENG




3428

[TnrSplyDelay : Setting]

Sets toner supply delay time.

001

Delay

*ENG

[0 to 255 / 0 / 1msec/step]




3429

[TnrSplyPosTime :Disp]

Sets toner supplying rate for fixed amount supplying mode.

001

Latest: K

*ENG


[0 to 20000 / 0 / 1msec/step]

002

Latest: C

*ENG

003

Latest: M

*ENG

004

Latest: Y

*ENG




3431

[DrvTime: Setting]

Sets toner supplying rate for fixed amount supplying mode.

001

Tmon:K

*ENG


[50 to 1000 / 200 / 50msec/step]

002

Tmon:C

*ENG

003

Tmon:M

*ENG

004

Tmon:Y

*ENG

Main SP Tables-3




3432

[DrvTime: Setting]

Sets max. continuous supplying time.

001

DriveTime(max)

*ENG

[0 to 1500 / 800 / 1msec/step]




3440

[Fixed Supply Mode]

Sets toner supplying rate for fixed amount supplying mode.

001

Fixed Rate: K

*ENG


[0 to 100 / 10 / 1%/step]

002

Fixed Rate: C

*ENG

003

Fixed Rate: M

*ENG

004

Fixed Rate: Y

*ENG




3450

[Toner Supply PID: Setting]

Sets supplying coefficient to supply proportion to Vt-Vtref with toner supply control. Uses PID control for toner supply.

001

Vt Proportion: K

*ENG


[0 to 2550 / 50 / 1/step]

002

Vt Proportion: C

*ENG

003

Vt Proportion: M

*ENG

004

Vt Proportion: Y

*ENG


3450

[Toner Supply PID: Setting]

Sets supplying coefficient to supply proportion to output image's pixel (Pxl) with toner supply control. Uses PID control for toner supply.

011

Pixel Proportion: K

*ENG


[0.00 to 2.55 / 0.47 / 0.01/step]

012

Pixel Proportion: C

*ENG

013

Pixel Proportion: M

*ENG

014

Pixel Proportion: Y

*ENG

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3




3450

[Toner Supply PID: Setting]

Displays current value of pixel proportionality coefficient 2 for supplying coefficient to supply proportion to output image's pixel (Pxl) with toner supply control. Uses PID control for toner supply.

021

Pixel Proportion 2: K

*ENG


[0.00 to 2.55 / 1.00 / 0.01/step]

022

Pixel Proportion 2: C

*ENG

023

Pixel Proportion 2: M

*ENG

024

Pixel Proportion 2: Y

*ENG


3450

[Toner Supply PID: Setting]

Sets supplying coefficient to supply proportion to output image's pixel (Pxl) with toner supply control. Uses PID control for toner supply.

031

Correction Coeffient: 1

*ENG

[0.00 to 2.55 / 1.00 / 0.01/step]

032

Correction Coeffient: 2

*ENG

[0.00 to 2.55 / 0.50 / 0.01/step]

033

Correction Coeffient: 3

*ENG

[0.00 to 2.55 / 0.00 / 0.01/step]

034

Correction Coeffient: 4

*ENG

[0.00 to 2.55 / 0.25 / 0.01/step]

035

Correction Coeffient: 5

*ENG

[0.00 to 2.55 / 0.50 / 0.01/step]


3450

[Toner Supply PID: Setting]

Displays current value of pixel proportionality coefficient 3 for supplying coefficient to supply proportion to output image's pixel (Pxl) with toner supply control. Uses PID control for toner supply.

041

Pixel Proportion 3: K

*ENG


[0.70 to 1.30 / 1.00 / 0.01/step]

042

Pixel Proportion 3: C

*ENG

043

Pixel Proportion 3: M

*ENG

044

Pixel Proportion 3: Y

*ENG


3450

[Toner Supply PID: Setting]

Sets supplying coefficient to supply proportion to output image's pixel (Pxl) with toner supply control. Uses PID control for toner supply.

Main SP Tables-3


051

Correction Value 1

*ENG

[-0.10 to 0.00 / -0.01 / 0.01/step]

052

Correction Value 2

*ENG

[0.00 to 0.10 / 0.01 / 0.01/step]


3450

[Toner Supply PID: Setting]

Sets transformation coefficient transforming pixel (cm^2) to supply amount (g) for supplying proportion to output image's pixel (Pxl) with toner supply control. Uses PID control for toner supply.

061

P_Pxl_Coef_Err

*ENG

[0.00 to 1.00 / 0.35 / 0.01/step]


3450

[Toner Supply PID: Setting]

Sets supplying coefficient to supply proportion to output image's pixel (Pxl) with toner supply control. Uses PID control for toner supply.

071

Vt Integral Control: K

*ENG


[0 to 2550 / 500 / 1/step]

072

Vt Integral Control: C

*ENG

073

Vt Integral Control: M

*ENG

074

Vt Integral Control: Y

*ENG


3450

[Toner Supply PID: Setting]

Sets supplying coefficient to supply in proportion to Diff. accumulate amount of Vt-Vtref with toner supply control. Uses PID control for toner supply.

081

Vt Integral Value: K

*ENG


[-255.00 to 255.00 / 0.00 /

0.01/step]

082

Vt Integral Value: C

*ENG

083

Vt Integral Value: M

*ENG

084

Vt Integral Value: Y

*ENG


3450

[Toner Supply PID: Setting]

Sets supplying coefficient to supply in proportion to Diff. accumulate amount of Vt-Vtref with toner supply control. Uses PID control for toner supply.

091

Vt Sum Times: K

*ENG


[1 to 255 / 20 / 1times/step]

092

Vt Sum Times: C

*ENG

093

Vt Sum Times: M

*ENG

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


094

Vt Sum Times: Y

*ENG




3460

[TonerSupply :DANC]


011

Time_Min

*ENG

[0 to 250 / 0 / 1msec/step]

Sets DANC min. supplying time.


012

Time_Max

*ENG

[0 to 1000 / 200 / 1msec/step]

Sets DANC max. supplying time.


3460

[TonerSupply :DANC]

Sets supplying amount for when creating SMITH model.

022

SMITH_Weight:K

*ENG


[1 to 500 / 140 / 1mg/step]

023

SMITH_Weight:CMY

*ENG


3460

[TonerSupply :DANC]

Sets transferring rate for to compensate reverse transfer amount of ANC term (pixel term).

111

Rev_Fix:K

*ENG


[1.00 to 1.50 / 1.00 / 0.01/step]

112

Rev_Fix:C

*ENG

113

Rev_Fix:M

*ENG

114

Rev_Fix:Y

*ENG


3460

[TonerSupply :DANC]

Sets delay time of from toner supplying door to sensor for SMITH model, by control sample count.

121

TnrSplyDelay:StdSpd:K

*ENG

[0 to 200 / 7 / 1/step]

122

TnrSplyDelay:MidSpd:K

*ENG

[0 to 200 / 13 / 1/step]

123

TnrSplyDelay:LowSpd:K

*ENG

[0 to 200 / 19 / 1/step]

131

TnrSplyDelay:StdSpd:CMY

*ENG

[0 to 200 / 7 / 1/step]

132

TnrSplyDelay:MidSpd:CMY

*ENG

[0 to 200 / 13 / 1/step]

133

TnrSplyDelay:LowSpd:CMY

*ENG

[0 to 200 / 19 / 1/step]

Main SP Tables-3



3461

[TonerSupply :DANC]


001

PI:Power

*ENG

[5 to 200 / 100 / 1%/step]

Changes all demand value of PI term.


011


PI:P Gain:K


*ENG

[0.0000 to 1.0000 / 0.0100 /

0.0001/step]

Sets P gain (K).


012

PI:P Limits:Up:K

*ENG

[0.00 to 1.00 / 0.10 / 0.01/step]

Sets limit against P term demanding value. (Supply plus side, K)


013

PI:P Limits:Low:K

*ENG

[0.00 to 1.00 / 0.10 / 0.01/step]

Sets limit against P term demanding value. (Supply minus side, K)


021


PI:I Gain:K


*ENG

[0.0000 to 1.0000 / 0.0010 /

0.0001/step]

Sets I gain (K).


022

PI:I Limits:Up:K

*ENG

[0.00 to 1.00 / 0.10 / 0.01/step]

Sets limit against I term demanding value. (Supply plus side, K)


023

PI:I Limits:Low:K

*ENG

[0.00 to 1.00 / 0.10 / 0.01/step]

Sets limit against I term demanding value. (Supply minus side, K)


031


PI:P Gain:CMY


*ENG

[0.0000 to 1.0000 / 0.0100 /

0.0001/step]

Sets P gain (CMY).


032

PI:P Limits:Up:CMY

*ENG

[0.00 to 1.00 / 0.10 / 0.01/step]

Sets limit against P term demanding value. (Supply plus side, CMY)


033

PI:P Limits:Low:CMY

*ENG

[0.00 to 1.00 / 0.10 / 0.01/step]

Sets limit against P term demanding value. (Supply minus side, CMY)


041


PI:I Gain:CMY


*ENG

[0.0000 to 1.0000 / 0.0010 /

0.0001/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



Sets I gain (CMY).


042

PI:I Limits:Up:CMY

*ENG

[0.00 to 1.00 / 0.10 / 0.01/step]

Sets limit against I term demanding value. (Supply plus side, CMY)


043

PI:I Limits:Low:CMY

*ENG

[0.00 to 1.00 / 0.10 / 0.01/step]

Sets limit against I term demanding value. (Supply minus side, CMY)


051

AW:AWIlow:K

*ENG

[0 to 10000 / 100 / 1/step]

Sets AW gain (K). (Normally reciprocal of P gain)


052

AW:AWIpni:K

*ENG

[0 to 2000 / 1000 / 1/step]

Sets rate to rapidly decrease accumulate value of difference between toner density and target value. (K: Supply plus side)


061

AW:AWIlow:CMY

*ENG

[0 to 10000 / 100 / 1/step]

Sets AW gain (CMY). (Normally reciprocal of P gain)


062

AW:AWIpni:CMY

*ENG

[0 to 2000 / 1000 / 1/step]

Sets rate to rapidly decrease accumulate value of difference between toner density and target value. (CMY: Supply plus side)


3461

[TonerSupply :DANC]

Corrects line speed for demand value of PI term.

102

PI:LineSpdCoef:MidSpd:K

*ENG


[0.05 to 1.00 / 0.50 / 0.01/step]

103

PI:LineSpdCoef:LowSpd:K

*ENG

112

PI:LineSpdCoef:StdSpd:CMY

*ENG

113

PI:LineSpdCoef:LowSpd:CMY

*ENG

3461

[TonerSupply :DANC]


121

SMITH:Gain:K

*ENG

[0.00 to 2.00 / 1.00 / 0.01/step]

Changes gain (amplitude of model) for SMITH model. (K)


122

SMITH:MidSpd:K

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Corrects line speed for gain of SMITH model. (Middle speed, K)

Main SP Tables-3



123

SMITH:LowSpd:K

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Corrects line speed for gain of SMITH model. (Low speed, K)


131

SMITH:Gain:CMY

*ENG

[0.00 to 2.00 / 1.00 / 0.01/step]

Changes gain (amplitude of model) for SMITH model. (CMY)


132

SMITH:MidSpd:CMY

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Corrects line speed for gain of SMITH model. (Middle speed, CMY)


133

SMITH:LowSpd:CMY

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Corrects line speed for gain of SMITH model. (Low speed, CMY)



3462

[TonerSupply :DANC]


001


ANC:Power


*ENG

[0 to 200 / 100 / 1%/step]

100: Standard control

0: No ANC

Changes all ANC filters demand value of ANC term.


101

ANC:Gain:K

*ENG

[0.00 to 2.00 / 1.00 / 0.01/step]

Sets gain for all ANC filters. (K)


102

ANC:MidSpd:K

*ENG

[0.05 to 1.00 / 1.00 / 0.01/step]

Corrects line speed for gain of all ANC filters. (Middle speed, K)


103

ANC:LowSpd:K

*ENG

[0.05 to 1.00 / 1.00 / 0.01/step]

Corrects line speed for gain of all ANC filters. (Low speed, K)


111

ANC:Gain:CMY

*ENG

[0.00 to 2.00 / 1.00 / 0.01/step]

Sets gain for all ANC filters. (CMY)


112

ANC:MidSpd:CMY

*ENG

[0.05 to 1.00 / 1.00 / 0.01/step]

Corrects line speed for gain of all ANC filters. (Middle speed, CMY)


113

ANC:LowSpd:CMY

*ENG

[0.05 to 1.00 / 1.00 / 0.01/step]

Corrects line speed for gain of all ANC filters. (Low speed, CMY)

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



3463

[TonerSupply :DANC]

Saves I term corresponding to power OFF/ON.

101

Int:I:K

*ENG


[-1000.0000 to 1000.0000 / 0.0000 /

0.0001/step]

102

Int:I:C

*ENG

103

Int:I:M

*ENG

104

Int:I:Y

*ENG


3463

[TonerSupply :DANC]

Saves ANC term (pixel term) corresponding to power OFF/ON.

111

ANC:ref Sum:K

*ENG


[-1000.0000 to 1000.0000 / 0.0000 /

0.0001/step]

112

ANC:ref Sum:C

*ENG

113

ANC:ref Sum:M

*ENG

114

ANC:ref Sum:Y

*ENG


3463

[TonerSupply :DANC]

Displays image area for the latest page.

201

ImgArea:K

*ENG


[0 to 9999 / 0 / 1cm2/step]

202

ImgArea:C

*ENG

203

ImgArea:M

*ENG

204

ImgArea:Y

*ENG



3500

[ImgQltyAdj :ON/OFF]


001


ALL


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

Sets execution judge to OFF of all imaging system adjustments.


002


ProCon


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

Main SP Tables-3



Sets execution judge to OFF of electric potential control.


003

MUSIC Condition:Auto Exe

*ENG

[0 or 1 / 1 / 1/step]

Forcedly sets MUSIC auto execution to OFF.


004


Init TD Sensor


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

Sets execution judge to OFF for initial setting of TD sensor.




3510

[ImgQltyAdj :ExeFlag]

Sets execution flag for toner recovery (Executes toner recovery with setting to "1" and power OFF/ON, or close front cover.)

001

Toner Recovery: K

*ENG


[0 to 3 / 0 / 1/step]

002

Toner Recovery: C

*ENG

003

Toner Recovery: M

*ENG

004

Toner Recovery: Y

*ENG


3510

[ImgQltyAdj :ExeFlag]

Sets execution flag for initial setting of TD sensor. (TD sensor's initial setting will be executed by setting to "1" and power OFF/ON)

011

Init TD Sensor :K

*ENG


[0 or 1 / 0 / 1/step]

012

Init TD Sensor :C

*ENG

013

Init TD Sensor :M

*ENG

014

Init TD Sensor :Y

*ENG

3510

[ImgQltyAdj :ExeFlag]


021

Process Control

*ENG

[0 to 2 / 0 / 1/step]

Sets execution flag for Pro-Con (Executes Pro-Con with setting to "1" and power OFF/ON, or close front cover.)

022

Developer Agitating

*ENG

[0 or 1 / 0 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



Sets execution flag for developer stir (Executes developer stir with setting to "1" and power OFF/ON, or close front cover.)


023

Blade Damage Prevention

*ENG

[0 or 1 / 0 / 1/step]

Sets execution flag for blade burr prevent mode (Executes blade burr prevent mode with setting to "1" and power OFF/ON or closing front cover.)


024


MUSIC


*ENG

[0 to 3 / 0 / 1/step]

0: OFF

1: Mode:b

2: Mode:a

3: Mode:e

Sets execution flag for MUSIC (MUSIC (1time) with setting "1" and power OFF/ON or closing font cover, MUSIC (2times) with setting "2", real time MUSIC with setting "3")


025

Vsg Adj.

*ENG

[0 or 1 / 0 / 1/step]

Sets execution flag for Vsg adjust (Executes Vsg adjust with setting to "1" and power OFF/ON, or close front cover.)


026

Charge AC Adj.

*ENG

[0 or 1 / 0 / 1/step]

Sets execution flag for Electrify roller cleaning (K) (Executes Electrify roller cleaning (K) with setting to "1" and power OFF/ON, or close from cover.)

3510

[ImgQltyAdj :ExeFlag]


031

Init Toner Replenish: K

*ENG

[0 or 1 / 0 / 1/step]

Sets execution flag for toner initial filler (K) (Executes toner recovery (K) with setting to "1" and power OFF/ON, or close front cover.)


032

Init Toner Replenish: C

*ENG

[0 or 1 / 0 / 1/step]

Sets execution flag for toner initial filler (C) (Executes toner recovery (C) with setting to "1" and power OFF/ON, or close front cover.)


033

Init Toner Replenish: M

*ENG

[0 or 1 / 0 / 1/step]

Sets execution flag for toner initial filler (M) (Executes toner recovery (M) with setting to "1" and power OFF/ON, or close front cover.)

034

Init Toner Replenish: Y

*ENG

[0 or 1 / 0 / 1/step]

Main SP Tables-3



Sets execution flag for toner initial filler (Y) (Executes toner recovery (Y) with setting to "1" and power OFF/ON, or close front cover.)

041

DEMS


[0 or 1 / 0 / 1/step]


042

IBACC

*ENG

[0 or 1 / 0 / 1/step]

Sets execution flag for toner initial filler (Y) (Executes toner recovery (Y) with setting to "1" and power OFF/ON, or close front cover.)


043

Vsg in TrnsBlt:corr

*ENG

[0 or 1 / 0 / 1/step]

Sets execution flag for toner initial filler (Y) (Executes toner recovery (Y) with setting to "1" and power OFF/ON, or close front cover.)


044

Dev. AC Adj.

*ENG

[0 or 1 / 0 / 1/step]

Sets execution flag for develop AC adjust (Executes with setting to "1" and power OFF/ON, or close from cover.)


045

BIT1

*ENG

[0 or 1 / 0 / 1/step]

Execution flag for image adjust of BIT 1 control.



3520

[ImgQltyAdj :Interval]


001

During Job

*ENG

[0 to 100 / 30 / 1page/step]

Sets image adjust judgment page interval for during print.


002

During Stand-by

*ENG

[0 to 100 / 5 / 1minute/step]

Sets image adjust judgment time interval for during standby.




3521

[Drum Stop Time :Disp]

Displays finish imaging time.

001

Year

*ENG

[0 to 99 / 0 / 1year/step]

002

Month

*ENG

[1 to 12 / 1 / 1month/step]

003

Day

*ENG

[1 to 31 / 1 / 1day/step/step]

004

Hour

*ENG

[0 to 23 / 0 / 1hour/step]

005

Minute

*ENG

[0 to 59/ 0 / 1 minutes/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



3522

[Drum Stop Environ :Disp]


001

Temperature

*ENG

[-1280.0 to 1270.0 / 0.0 / 0.1deg]

Displays (temperature) of when imaging finished.


002

Rel Humidity

*ENG

[0.0 to 1000.0 / 0.0 / 0.1%RH/step]

Displays (relative humidity) of when imaging finished.


003

Abs Humidity

*ENG

[0.0 to 1000.0 / 0.0 / 0.1g/m3/step]

Displays (absolute humidity) of when imaging finished.



3529

[ProCon Interval Control :Set]


001


Gamma Corr


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

Sets ON/OFF develop gamma correction for Pro-Con auto execute interval.


002


Environ Corr


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

Sets ON/OFF environment correction for Pro-Con auto execute interval.


003

AbsHum Threshhold

*ENG

[0.0 to 99.0 / 4.3 / 0.1g/m3/step]

Sets absolute humidity threshold of environment correction for Pro-Con auto execute interval.


004

Max Cnt Threshhold

*ENG

[0 to 99 / 2 / 1counts/step]

Sets max. count threshold of Interrupt Pro-Con/Job end Pro-Con.


005

Exe Cnt

ENG

[0 to 255 / 0 / 1counts/step]

Sets max. count counter of Interrupt Pro-Con/Job end Pro-Con.


006

Page Cnt:BW

*ENG

[0 to 5000 / 0 / 1sheet/step]

Displays Pro-Con (BW) sheets count.

007

Page Cnt:FC

*ENG

[0 to 5000 / 0 / 1sheet/step]

Main SP Tables-3



Displays Pro-Con (FC) sheets count.



3530

[PowerON ProCon :Se]


001

Non-use Time Setting

*ENG

[0 to 1440 / 360 / 1minute/step]

Sets Pro-Con execute judgment threshold of when Power ON.


002

Temperature Range

*ENG

[0 to 99 / 10 / 1deg/step]

Sets Pro-Con execute judgment threshold of when Power ON.


003

Relative Humidity Range

*ENG

[0 to 99 / 50 / 1%RH/step]

Sets Pro-Con execute judgment threshold of when Power ON.


004

Absolute Humidity Range

*ENG

[0 to 99 / 6 / 1g/m3/step]

Sets Pro-Con execute judgment threshold of when Power ON.


005

Interval:BW

*ENG

[0 to 5000 / 250 / 1sheet/step]

Sets Pro-Con execute judgment threshold of when Power ON.


006

Interval:FC

*ENG

[0 to 5000 / 100 / 1sheet/step]

Sets Pro-Con execute judgment threshold of when Power ON.


007

Page Cnt:BW

*ENG

[0 to 5000 / 0 / 1 sheet/step]

Sets sheets count for Power ON Pro-Con (BW).


008

Page Cnt:FC

*ENG

[0 to 5000 / 0 / 1 sheet/step]

Sets sheets count for Power ON Pro-Con (FC).




3531

[Non-useTime Procon :Set]

Sets Pro-Con execute judgment threshold for during standby.

001

Non-use Time Setting

*ENG

[0 to 1440 / 360 / 1minute/step]

002

Temperature Range

*ENG

[0 to 99 / 10 / 1deg/step]

003

Relative Humidity Range

*ENG

[0 to 99 / 50 / 1%RH/step]

004

Absolute Humidity Range

*ENG

[0 to 99 / 6 / 1g/m3/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



3531

[Non-useTime Procon :Set]

Sets upper limit of continuously executing count for Pro-Con during standby.

005

Maximum Execution Number

*ENG

[0 to 99 / 10 / 1times/step]



3533

[Interrupt ProCon :Set]


001

Interval:Set:BW

*ENG

[0 to 5000 / 500 / 1sheet/step]

Sets number of sheets interval for Interrupt Pro-Con (BW).


002

Interval:Disp:BW

*ENG

[0 to 5000 / 500 / 1sheet/step]

Displays number of sheets interval for Interrupt Pro-Con (BW).


003

Corr(Short):BW

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Sets correcting coefficient (Short) of number of sheets interval for Interrupt Pro-Con (BW).


004

Corr(Mid):BW

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Sets correcting coefficient (Mid) of number of sheets interval for Interrupt Pro-Con (BW).


011

Interval:Set:FC

*ENG

[0 to 5000 / 200 / 1sheet/step]

Sets number of sheets interval for Interrupt Pro-Con (FC).


012

Interval:Disp:FC

*ENG

[0 to 5000 / 200 / 1sheet/step]

Displays number of sheets interval for Interrupt Pro-Con (FC).


013

Corr(Short):FC

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Sets correcting coefficient (Short) of number of sheets interval for Interrupt Pro-Con (FC).


014

Corr(Mid):FC

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Sets correcting coefficient (Mid) of number of sheets interval for Interrupt Pro-Con (FC).

Main SP Tables-3



3534

[JobEnd ProCon :Set]


001

Interval:Set:BW

*ENG

[0 to 5000 / 500 / 1sheet/step]

Sets number of sheets interval for Job end Pro-Con (BW).


002

Interval:Disp:BW

*ENG

[0 to 5000 / 500 / 1sheet/step]

Displays number of sheets interval for Job end Pro-Con (BW).


003

Corr(Short):BW

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Sets correcting coefficient (Short) of number of sheets interval for Job end Pro-Con (BW).


004

Corr(Mid):BW

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Sets correcting coefficient (Mid) of number of sheets interval for Job end Pro-Con (BW).


011

Interval:Set:FC

*ENG

[0 to 1000 / 200 / 1sheet/step]

Sets number of sheets interval for Job end Pro-Con (FC).


012

Interval:Disp:FC

*ENG

[0 to 5000 / 200 / 1sheet/step]

Displays number of sheets interval for Job end Pro-Con (FC).


013

Corr(Short):FC

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Sets correcting coefficient (Short) of number of sheets interval for Job end Pro-Con (FC).


014

Corr(Mid):FC

*ENG

[0.00 to 1.00 / 1.00 / 0.01/step]

Sets correcting coefficient (Mid) of number of sheets interval for Job end Pro-Con (FC).



3539

[Dev Agitating Time :Set]


001

Time

*ENG

[0 to 3000 / 10 / 1sec/step]

Sets Developer Agitating Time.


010

ON/OFF(by RelHum)

*ENG

[0 or 1 / 1 / 1/step]

Sets ON/OFF for Absolute Humidity Correction for Developer Agitating Time.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



3539

[Dev Agitating Time :Set]

Sets stirring time based on relative humidity of developer stirring time.

011

by RelHum:1

*ENG

[0 to 3000 / 0 / 1sec/step]

012

by RelHum:2

*ENG


[0 to 3000 / 5 / 1sec/step]

013

by RelHum:3

*ENG

014

by RelHum:4

*ENG

015

by RelHum:5

*ENG

016

by RelHum:6

*ENG

021

RelHum Threshold:1

*ENG

[0 to 1000 / 4 / 1%RH/step]

022

RelHum Threshold:2

*ENG

[0 to 1000 / 8 / 1%RH/step]

023

RelHum Threshold:3

*ENG

[0 to 1000 / 12 / 1%RH/step]

024

RelHum Threshold:4

*ENG

[0 to 1000 / 16 / 1%RH/step]

025

RelHum Threshold:5

*ENG

[0 to 1000 / 24 / 1%RH/step]

3539

[Dev Agitating Time :Set]


030

ON/OFF(by Non-use Time)

*ENG

[0 or 1 / 1 / 1/step]

Sets ON/OFF exposure time correction of developer stirring time.

031

by Non-use Time:1



[0 to 3000 / 0 / 1sec/step]

032

by Non-use Time:2


033

by Non-use Time:3


034

by Non-use Time:4


035

by Non-use Time:5


036

by Non-use Time:6


037

by Non-use Time:7


038

by Non-use Time:8


039

by Non-use Time:9


040

by Non-use Time:10


Main SP Tables-3


041

Non-use Time Threshhold:1


[0 to 5000 / 15 / 1min/step]

042

Non-use Time Threshhold:2


[0 to 5000 / 30 / 1min/step]

043

Non-use Time Threshhold:3


[0 to 5000 / 60 / 1min/step]

044

Non-use Time Threshhold:4


[0 to 5000 / 120 / 1min/step]

045

Non-use Time Threshhold:5


[0 to 5000 / 240 / 1min/step]

046

Non-use Time Threshhold:6


[0 to 5000 / 360 / 1min/step]

047

Non-use Time Threshhold:7


[0 to 5000 / 720 / 1min/step]

048

Non-use Time Threshhold:8


[0 to 5000 / 1440 / 1min/step]

049

Non-use Time Threshhold:9


[0 to 5000 / 2880 / 1min/step]


050

ON/OFF(by Non-use Time)

*ENG

[0 or 1 / 1 / 1/step]

Sets ON/OFF image area correction of developer stirring time.


3539

[Dev Agitating Time :Set]

Sets stirring time based on image area of developer stirring time.

051

by DotCoverage :1

*ENG


[0 to 3000 / 0 / 1sec/step]

052

by DotCoverage :2

*ENG

053

by DotCoverage :3

*ENG


[0 to 3000 / 5 / 1sec/step]

054

by DotCoverage :4

*ENG

055

by DotCoverage :5

*ENG

056

by DotCoverage :6

*ENG


3539

[Dev Agitating Time :Set]

Sets image area threshold of developer stirring time.

061

DotCoverage Threshhold:1

*ENG

[0 to 5000 / 10 / 1min/step]

062

DotCoverage Threshhold:2

*ENG

[0 to 5000 / 20 / 1min/step]

063

DotCoverage Threshhold:3

*ENG

[0 to 5000 / 30 / 1min/step]

064

DotCoverage Threshhold:4

*ENG

[0 to 5000 / 40 / 1min/step]

065

DotCoverage Threshhold:5

*ENG

[0 to 5000 / 50 / 1min/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


3539

[Dev Agitating Time :Set]


099

UpperLimit

*ENG

[0 to 3600 / 3600 / 1sec/step]

Sets upper limit of developer stirring time.




3540

[PowerON Music :Set]

Sets sheets count for Power ON MUSIC.

001

Page Cnt:BW

*ENG


[0 to 5000 / 0 / 1sheet/step]

002

Page Cnt:FC

*ENG




3541

[Music Interval :Set]

Sets sheets count for Power ON MUSIC.

001

Page Cnt:BW

*ENG


[0 to 5000 / 0 / 1sheet/step]

002

Page Cnt:FC

*ENG


3541

[Realtime Music Interval :Set]

Saves / Updates this SP with print count in B&W + color mode since the last MUSIC for to use with real time MUSIC.

003

Page Cnt:BW+FC

*ENG

[0 to 5000 / 0 / 1sheet/step]




3550

[Refresh Mode]

Display image area needs to be refreshed. Consumes toner with density adjust or when print finished if this value is larger than set.

001

Required Area: K

*ENG


[0 to 65535 / 0 / 1cm^2]

002

Required Area: C

*ENG

003

Required Area: M

*ENG

004

Required Area: Y

*ENG


3550

[Refresh Mode]

Uses for to calculate discharge amount when discharging toner at end of print.

Main SP Tables-3



011

Dev. Unit Rotation: Display: Bk


*ENG


[0.0 to 1000.0 / 0.0 / 0.1m/step]

012

Dev. Unit Rotation: Display: C

*ENG

013

Dev. Unit Rotation: Display: M

*ENG

014

Dev. Unit Rotation: Display: Y

*ENG

3550

[Refresh Mode]


021

Rotation Threshold

*ENG

[0.0 to 1000.0 / 0.1 / 0.1m/step]

Uses for execute judging of discharging toner at end of print.


3550

[Refresh Mode]

Uses for to calculate discharge amount when discharging toner at end of print. With increasing the value, more will be discharged.

031

Reflesh Threshold: Bk

*ENG


[0 to 255 / 17 / 1cm^2/step]

032

Reflesh Threshold: C

*ENG

033

Reflesh Threshold: M

*ENG

034

Reflesh Threshold: Y

*ENG

3550

[Refresh Mode]


035

Mode Selection Coefficient

ENG

[0 or 1 / 1 / 1/step]

Uses for to calculate discharge amount when discharging toner at end of print.


3550

[Refresh Mode]

Uses for to calculate discharge amount when discharging toner at end of print. With increasing the value, more will be discharged.

041

Job End Area Coefficient:K

*ENG

[0.1 to 25.5 / 1.0 / 0.1/step]

042

Job End Vb Coefficient:K

*ENG

[0 to 100 / 40 / 1%/step]

043

Job End Length:K

*ENG

[0 to 255 / 25 / 1mm/step]


044


Job End Supply


*ENG

[0.000 to 1.000 / 0.450 /

0.001mg/cm^2]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



045

Job End Area Coefficient:YMC


*ENG


[0.1 to 25.5 / 1.0 / 0.1/step]

046

Job End Vb Coefficient:YMC

*ENG

[0 to 100 / 40 / 1%/step]

047

Job End Length:YMC

*ENG

[0 to 255 / 25 / 1mm/step]

3550

[Refresh Mode]


081

TC Adj. Consume(Upp Limit)

*ENG

[0 to 255 / 20 / 1times/step]

Sets consume counts (upper limit) for toner density adjusting Pro-Con.



3552

[Blade damage prevention mode]


001

Execution Temp. Threshold

*ENG

[0 to 50 / 40 / 1deg/step]

Sets temperature threshold for creating blade Tear off prevent pattern.



3553

[Transfer belt cleaning]


001

TransferIdleTime Temperature:H


*ENG

[0.0 to 3.0 / 0.0 /

0.1revolutions/step]

Prevents poor cleaning by racing the image transfer when going over temperature threshold t2 and poor cleaning occurred right after Pro-Con/MUSIC etc... adjust pattern was entered.


002

TransferIdleTime Temperature:M


*ENG

[0.0 to 3.0 / 0.0 /

0.1revolutions/step]

Prevents poor cleaning by racing the image transfer when between temperature threshold t1to t2 and poor cleaning occurred right after Pro-Con/MUSIC etc... adjust pattern was entered.


003

TransferIdleTime Temperature:L


*ENG

[0.0 to 3.0 / 0.0 /

0.1revolutions/step]

Prevents poor cleaning by racing the image transfer when smaller than temperature threshold t1 and poor cleaning occurred right after Pro-Con/MUSIC etc... adjust pattern was entered.


004

TransferIdleTime Temperature:L:ON


*ENG

[0.0 to 3.0 / 0.0 /

0.1revolutions/step]

Main SP Tables-3



Prevents poor cleaning by racing the image transfer when smaller than temperature threshold t1 and poor cleaning occurred right after Pro-Con/MUSIC etc... adjust pattern was entered when starting up machine fist in the morning.


005

Temperature Threshold:T2

*ENG

[20 to 30 / 25 / 1deg/step]

Adjusts temperature threshold of poor cleaning to occur after Pro-Con/MUSIC etc... adjusting pattern was entered.


006

Temperature Threshold:T1

*ENG

[0 to 15 / 15 / 1deg/step]

Adjusts temperature threshold of poor cleaning to occur after Pro-Con/MUSIC etc... adjusting pattern was entered.


007

Temperature Threshold:T3

*ENG

[0 to 30 / 5 / 1deg/step]

Adjusts threshold for wide stripes to occur in the image of the next job caused by image transfer belt cleaning after job stops.



3554

[TransBltCleanBladeReplMode:Exe]


001

Execute

ENG

[0 or 1 / 0 / 1/step]

Executes replace mode of paper transfer cleaning blade.

* Specification unapplied SP, No use.


002

Idle Time

ENG

[0.1 to 60.0 / 10.0 / 0.1sec/step]

Sets paper transfer racing time for when replace mode of paper transfer cleaning blade.

* Specification unapplied SP, No use.



3555

[ImageQuality Adj. Counter:Disp]


001

Charge AC Control

*ENG

[0 to 2000 / 0 / 1page/step]

For to use with adjusting control of electrify AC bias.



3600

[Select ProCon]


001


Potential Control


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



Sets electric potential control method.


002


LD Control


*ENG

[0 to 3 / 1 / 1/step]

0: OFF

1: ON

Sets LD control method.


003


TC Adj. Mode


*ENG

[0 to 3 / 3 / 1/step] 0: Do Not Execute 1: 1st Power On

2: 1st Power On & Job End 3: 1st P_On & JE &printing

Sets Execution timing of toner density adjusting Pro-Con.


004


ACC Before ProCon


*ENG

[0 to 3 / 2 / 1/step]

0: NotExecute

1: ProcessControl

2: TCContorol

Executes same action as Pro-Con executed before ACC, from SP.


006


Pattern Cal. Method


*ENG

[0 to 3 / 0 / 1/step]

0: FIXED

1: INITIALIZED

2: CALCULATED

Executes same action as Pro-Con executed before ACC, from SP.


010


ActivePotentialControl


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

Sets electric potential control method for during printing.


030


IBACC:ON/OFF


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

Sets execute ON/OFF of IBACC.


060


Vsg ITB Internal Circumference Correction


*ENG

[0 or 1 / 1 / 1/step]

0: OFF

1: ON

Main SP Tables-3



Sets execute ON/OFF of Vsg paper transfer internal rotate correction.




3610

[Chrg AC Control]

Displays electrify AC control value decided with electrify AC control.

001

Std Speed: K

*ENG


[0.00 to 3.00 / 2.20 / 0.01kV]

002

Std Speed: C

*ENG

003

Std Speed: M

*ENG

004

Std Speed: Y

*ENG




3611

[Chrg DC Control]

Displays electrify DC bias decided with Pro-Con.

001

Std Speed: K

*ENG


[300 to 1000 / 690 / 1-V/step]

002

Std Speed: C

*ENG

003

Std Speed: M

*ENG

004

Std Speed: Y

*ENG

011

Mid Speed: K

*ENG

012

Mid Speed: C

*ENG

013

Mid Speed: M

*ENG

014

Mid Speed: Y

*ENG

021

Low Speed: K

*ENG

022

Low Speed: C

*ENG

023

Low Speed: M

*ENG

024

Low Speed: Y

*ENG


3611

[Chrg DC Control]

Displays electrify DC bias decided with Pro-Con.

031

Std Speed: K (Front)


[300 to 1000 / 690 / 1-V/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


032

Std Speed: C (Front)


[300 to 1000 / 690 / 1-V/step]

033

Std Speed: M (Front)


[300 to 1000 / 690 / 1-V/step]

034

Std Speed: Y (Front)


[300 to 1000 / 690 / 1-V/step]

041

Mid Speed: K (Front)


[300 to 1000 / 690 / 1-V/step]

042

Mid Speed: C (Front)


[300 to 1000 / 690 / 1-V/step]

043

Mid Speed: M (Front)


[300 to 1000 / 690 / 1-V/step]

044

Mid Speed: Y (Front)


[300 to 1000 / 690 / 1-V/step]

051

Low Speed: K (Front)


[300 to 1000 / 690 / 1-V/step]

052

Low Speed: C (Front)


[300 to 1000 / 690 / 1-V/step]

053

Low Speed: M (Front)


[300 to 1000 / 690 / 1-V/step]

054

Low Speed: Y (Front)


[300 to 1000 / 690 / 1-V/step]

061

Std Speed: K (Center)


[300 to 1000 / 690 / 1-V/step]

062

Std Speed: C (Center)


[300 to 1000 / 690 / 1-V/step]

063

Std Speed: M (Center)


[300 to 1000 / 690 / 1-V/step]

064

Std Speed: Y (Center)


[300 to 1000 / 690 / 1-V/step]

071

Mid Speed: K (Center)


[300 to 1000 / 690 / 1-V/step]

072

Mid Speed: C (Center)


[300 to 1000 / 690 / 1-V/step]

073

Mid Speed: M (Center)


[300 to 1000 / 690 / 1-V/step]

074

Mid Speed: Y (Center)


[300 to 1000 / 690 / 1-V/step]

081

Low Speed: K (Center)


[300 to 1000 / 690 / 1-V/step]

082

Low Speed: C (Center)


[300 to 1000 / 690 / 1-V/step]

083

Low Speed: M (Center)


[300 to 1000 / 690 / 1-V/step]

084

Low Speed: Y (Center)


[300 to 1000 / 690 / 1-V/step]

091

Std Speed: K (Rear)


[300 to 1000 / 690 / 1-V/step]

092

Std Speed: C (Rear)


[300 to 1000 / 690 / 1-V/step]

093

Std Speed: M (Rear)


[300 to 1000 / 690 / 1-V/step]

Main SP Tables-3


094

Std Speed: Y (Rear)


[300 to 1000 / 690 / 1-V/step]

101

Mid Speed: K (Rear)


[300 to 1000 / 690 / 1-V/step]

102

Mid Speed: C (Rear)


[300 to 1000 / 690 / 1-V/step]

103

Mid Speed: M (Rear)


[300 to 1000 / 690 / 1-V/step]

104

Mid Speed: Y (Rear)


[300 to 1000 / 690 / 1-V/step]

111

Low Speed: K (Rear)


[300 to 1000 / 690 / 1-V/step]

112

Low Speed: C (Rear)


[300 to 1000 / 690 / 1-V/step]

113

Low Speed: M (Rear)


[300 to 1000 / 690 / 1-V/step]

114

Low Speed: Y (Rear)


[300 to 1000 / 690 / 1-V/step]

201

Now:Std Speed: K

ENG

[300 to 1000 / 690 / 1-V/step]

202

Now:Std Speed: C

ENG

[300 to 1000 / 690 / 1-V/step]

203

Now:Std Speed: M

ENG

[300 to 1000 / 690 / 1-V/step]

204

Now:Std Speed: Y

ENG

[300 to 1000 / 690 / 1-V/step]


3611

[Chrg DC Control]

Electrify bias to actually set including value corrected with RTP.

211

Now:Mid Speed: K

ENG

[300 to 1000 / 690 / 1-V/step]

212

Now:Mid Speed: C

ENG

[300 to 1000 / 690 / 1-V/step]

213

Now:Mid Speed: M

ENG

[300 to 1000 / 690 / 1-V/step]

214

Now:Mid Speed: Y

ENG

[300 to 1000 / 690 / 1-V/step]

221

Now:Low Speed: K

ENG

[300 to 1000 / 690 / 1-V/step]

222

Now:Low Speed: C

ENG

[300 to 1000 / 690 / 1-V/step]

223

Now:Low Speed: M

ENG

[300 to 1000 / 690 / 1-V/step]

224

Now:Low Speed: Y

ENG

[300 to 1000 / 690 / 1-V/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3




3612

[Dev DC Control]

Displays develop bias decided with Pro-Con.

001

Std Speed: K

*ENG

[200 to 800 / 550 / 1-V/step]

002

Std Speed: C

*ENG

[200 to 800 / 550 / 1-V/step]

003

Std Speed: M

*ENG

[200 to 800 / 550 / 1-V/step]

004

Std Speed: Y

*ENG

[200 to 800 / 550 / 1-V/step]

011

Mid Speed: K

*ENG

[200 to 800 / 550 / 1-V/step]

012

Mid Speed: C

*ENG

[200 to 800 / 550 / 1-V/step]

013

Mid Speed: M

*ENG

[200 to 800 / 550 / 1-V/step]

014

Mid Speed: Y

*ENG

[200 to 800 / 550 / 1-V/step]

021

Low Speed: K

*ENG

[200 to 800 / 550 / 1-V/step]

022

Low Speed: C

*ENG

[200 to 800 / 550 / 1-V/step]

023

Low Speed: M

*ENG

[200 to 800 / 550 / 1-V/step]

024

Low Speed: Y

*ENG

[200 to 800 / 550 / 1-V/step]

031

Std Speed: K (Front)


[200 to 800 / 550 / 1-V/step]

032

Std Speed: C (Front)


[200 to 800 / 550 / 1-V/step]

033

Std Speed: M (Front)


[200 to 800 / 550 / 1-V/step]

034

Std Speed: Y (Front)


[200 to 800 / 550 / 1-V/step]

041

Mid Speed: K (Front)


[200 to 800 / 550 / 1-V/step]

042

Mid Speed: C (Front)


[200 to 800 / 550 / 1-V/step]

043

Mid Speed: M (Front)


[200 to 800 / 550 / 1-V/step]

044

Mid Speed: Y (Front)


[200 to 800 / 550 / 1-V/step]

051

Low Speed: K (Front)


[200 to 800 / 550 / 1-V/step]

052

Low Speed: C (Front)


[200 to 800 / 550 / 1-V/step]

053

Low Speed: M (Front)


[200 to 800 / 550 / 1-V/step]

Main SP Tables-3


054

Low Speed: Y (Front)


[200 to 800 / 550 / 1-V/step]

061

Std Speed: K (Center)


[200 to 800 / 550 / 1-V/step]

062

Std Speed: C (Center)


[200 to 800 / 550 / 1-V/step]

063

Std Speed: M (Center)


[200 to 800 / 550 / 1-V/step]

064

Std Speed: Y (Center)


[200 to 800 / 550 / 1-V/step]

071

Mid Speed: K (Center)


[200 to 800 / 550 / 1-V/step]

072

Mid Speed: C (Center)


[200 to 800 / 550 / 1-V/step]

073

Mid Speed: M (Center)


[200 to 800 / 550 / 1-V/step]

074

Mid Speed: Y (Center)


[200 to 800 / 550 / 1-V/step]

081

Low Speed: K (Center)


[200 to 800 / 550 / 1-V/step]

082

Low Speed: C (Center)


[200 to 800 / 550 / 1-V/step]

083

Low Speed: M (Center)


[200 to 800 / 550 / 1-V/step]

084

Low Speed: Y (Center)


[200 to 800 / 550 / 1-V/step]

091

Std Speed: K (Rear)


[200 to 800 / 550 / 1-V/step]

092

Std Speed: C (Rear)


[200 to 800 / 550 / 1-V/step]

093

Std Speed: M (Rear)


[200 to 800 / 550 / 1-V/step]

094

Std Speed: Y (Rear)


[200 to 800 / 550 / 1-V/step]

101

Mid Speed: K (Rear)


[200 to 800 / 550 / 1-V/step]

102

Mid Speed: C (Rear)


[200 to 800 / 550 / 1-V/step]

103

Mid Speed: M (Rear)


[200 to 800 / 550 / 1-V/step]

104

Mid Speed: Y (Rear)


[200 to 800 / 550 / 1-V/step]

111

Low Speed: K (Rear)


[200 to 800 / 550 / 1-V/step]

112

Low Speed: C (Rear)


[200 to 800 / 550 / 1-V/step]

113

Low Speed: M (Rear)


[200 to 800 / 550 / 1-V/step]

114

Low Speed: Y (Rear)


[200 to 800 / 550 / 1-V/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



3612

[Dev DC Control]


120

Set:Vb Limit

*ENG

[0 to 500 / 50 / 1V/step]

Controls bias variable amount when Pro-Con interrupting.


3612

[Dev DC Control]

Sets upper limit develop Vb.

121

Set:Limit TC1

*ENG

[1.0 to 15.0 / 6.5 / 0.1wt%/step]

122

Set:Limit TC2

*ENG

[1.0 to 15.0 / 7.0 / 0.1wt%/step]

123

Set:Page Thresh

*ENG

[0 to 999999 / 35000 / 1page/step]

131

Set:Upper Vb Current:K

*ENG


[0 to 800 / 600 / 1V/step]

132

Set:Upper Vb Current:C

*ENG

133

Set:Upper Vb Current:M

*ENG

134

Set:Upper Vb Current:Y

*ENG


3612

[Dev DC Control]

Develop bias to actually set including value corrected with RTP.

201

Now:Std Speed: K

ENG

[200 to 800 / 690 / 1-V/step]

202

Now:Std Speed: C

ENG

[200 to 800 / 690 / 1-V/step]

203

Now:Std Speed: M

ENG

[200 to 800 / 690 / 1-V/step]

204

Now:Std Speed: Y

ENG

[200 to 800 / 690 / 1-V/step]

211

Now:Mid Speed: K

ENG

[200 to 800 / 690 / 1-V/step]

212

Now:Mid Speed: C

ENG

[200 to 800 / 690 / 1-V/step]

213

Now:Mid Speed: M

ENG

[200 to 800 / 690 / 1-V/step]

214

Now:Mid Speed: Y

ENG

[200 to 800 / 690 / 1-V/step]

221

Now:Low Speed: K

ENG

[200 to 800 / 690 / 1-V/step]

222

Now:Low Speed: C

ENG

[200 to 800 / 690 / 1-V/step]

223

Now:Low Speed: M

ENG

[200 to 800 / 690 / 1-V/step]

Main SP Tables-3


224

Now:Low Speed: Y

ENG

[200 to 800 / 690 / 1-V/step]




3613

[LD Power Control]

Displays LD power decided with Pro-Con.

001

Std Speed: K

*ENG

[0 to 200 / 100 / 1%/step]

002

Std Speed: C


[0 to 200 / 100 / 1%/step]

003

Std Speed: M


[0 to 200 / 100 / 1%/step]

004

Std Speed: Y


[0 to 200 / 100 / 1%/step]

011

Mid Speed: K


[0 to 200 / 100 / 1%/step]

012

Mid Speed: C


[0 to 200 / 100 / 1%/step]

013

Mid Speed: M


[0 to 200 / 100 / 1%/step]

014

Mid Speed: Y


[0 to 200 / 100 / 1%/step]

021

Std Speed: K


[0 to 200 / 100 / 1%/step]

022

Std Speed: C


[0 to 200 / 100 / 1%/step]

023

Std Speed: M


[0 to 200 / 100 / 1%/step]

024

Std Speed: Y


[0 to 200 / 100 / 1%/step]

031

Std Speed: K (Front)


[0 to 200 / 100 / 1%/step]

032

Std Speed: C (Front)


[0 to 200 / 100 / 1%/step]

033

Std Speed: M (Front)


[0 to 200 / 100 / 1%/step]

034

Std Speed: Y (Front)


[0 to 200 / 100 / 1%/step]

041

Mid Speed: K (Front)


[0 to 200 / 100 / 1%/step]

042

Mid Speed: C (Front)


[0 to 200 / 100 / 1%/step]

043

Mid Speed: M (Front)


[0 to 200 / 100 / 1%/step]

044

Mid Speed: Y (Front)


[0 to 200 / 100 / 1%/step]

051

Low Speed: K (Front)


[0 to 200 / 100 / 1%/step]

052

Low Speed: C (Front)


[0 to 200 / 100 / 1%/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


053

Low Speed: M (Front)


[0 to 200 / 100 / 1%/step]

054

Low Speed: Y (Front)


[0 to 200 / 100 / 1%/step]

061

Std Speed: K (Center)


[0 to 200 / 100 / 1%/step]

062

Std Speed: C (Center)


[0 to 200 / 100 / 1%/step]

063

Std Speed: M (Center)


[0 to 200 / 100 / 1%/step]

064

Std Speed: Y (Center)


[0 to 200 / 100 / 1%/step]

071

Mid Speed: K (Center)


[0 to 200 / 100 / 1%/step]

072

Mid Speed: C (Center)


[0 to 200 / 100 / 1%/step]

073

Mid Speed: M (Center)


[0 to 200 / 100 / 1%/step]

074

Mid Speed: Y (Center)


[0 to 200 / 100 / 1%/step]

081

Low Speed: K (Center)


[0 to 200 / 100 / 1%/step]

082

Low Speed: C (Center)


[0 to 200 / 100 / 1%/step]

083

Low Speed: M (Center)


[0 to 200 / 100 / 1%/step]

084

Low Speed: Y (Center)


[0 to 200 / 100 / 1%/step]

091

Std Speed: K (Rear)


[0 to 200 / 100 / 1%/step]

092

Std Speed: C (Rear)


[0 to 200 / 100 / 1%/step]

093

Std Speed: M (Rear)


[0 to 200 / 100 / 1%/step]

094

Std Speed: Y (Rear)


[0 to 200 / 100 / 1%/step]


3613

[LD Power Control]

LD Power of Pro-Con pattern part.

101

PrcsCntrlCorrect:K

ENG

[0 to 200 / 140 / 1%/step]

102

PrcsCntrlCorrect:C

ENG

[0 to 200 / 140 / 1%/step]

103

PrcsCntrlCorrect:M

ENG

[0 to 200 / 140 / 1%/step]

104

PrcsCntrlCorrect:Y

ENG

[0 to 200 / 140 / 1%/step]

111

Low Speed: K (Rear)


[0 to 200 / 140 / 1%/step]

112

Low Speed: C (Rear)


[0 to 200 / 140 / 1%/step]

Main SP Tables-3


113

Low Speed: M (Rear)


[0 to 200 / 140 / 1%/step]

114

Low Speed: Y (Rear)


[0 to 200 / 140 / 1%/step]

121

Mid Speed: K (Rear)


[0 to 200 / 140 / 1%/step]

122

Mid Speed: C (Rear)


[0 to 200 / 140 / 1%/step]

123

Mid Speed: M (Rear)


[0 to 200 / 140 / 1%/step]

124

Mid Speed: Y (Rear)


[0 to 200 / 140 / 1%/step]


3613

[LD Power Control]

Ld Power to actually set including value corrected with RTP.

201

Now:Std Speed: K

ENG

[0 to 200 / 100 / 1%/step]

202

Now:Std Speed: C

ENG

[0 to 200 / 100 / 1%/step]

203

Now:Std Speed: M

ENG

[0 to 200 / 100 / 1%/step]

204

Now:Std Speed: Y

ENG

[0 to 200 / 100 / 1%/step]

211

Now:Mid Speed: K

ENG

[0 to 200 / 100 / 1%/step]

212

Now:Mid Speed: C

ENG

[0 to 200 / 100 / 1%/step]

213

Now:Mid Speed: M

ENG

[0 to 200 / 100 / 1%/step]

214

Now:Mid Speed: Y

ENG

[0 to 200 / 100 / 1%/step]

221

Now:Low Speed: K

ENG

[0 to 200 / 100 / 1%/step]

222

Now:Low Speed: C

ENG

[0 to 200 / 100 / 1%/step]

223

Now:Low Speed: M

ENG

[0 to 200 / 100 / 1%/step]

224

Now:Low Speed: Y

ENG

[0 to 200 / 100 / 1%/step]




3619

[Bias:Spd Corr]

Sets correction conditions per line speed of develop bias.

001

VbCoef:Std Spd: K

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

002

VbCoef:Std Spd: C

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

003

VbCoef:Std Spd: M

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


004

VbCoef:Std Spd: Y

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

011

VbCoef:Mid Spd: K

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

012

VbCoef:Mid Spd: C

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

013

VbCoef:Mid Spd: M

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

014

VbCoef:Mid Spd: Y

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

021

VbCoef:Low Spd: K

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

022

VbCoef:Low Spd: C

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

023

VbCoef:Low Spd: M

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

024

VbCoef:Low Spd: Y

*ENG

[0.50 to 1.50 / 1.00 / 0.01/step]

051

Offset: Std Spd: K

*ENG

[-128 to 127 / 39 / 1V/step]

052

Offset: Std Spd: C

*ENG

[-128 to 127 / 39 / 1V/step]

053

Offset: Std Spd: M

*ENG

[-128 to 127 / 39 / 1V/step]

054

Offset: Std Spd: Y

*ENG

[-128 to 127 / 39 / 1V/step]

061

Offset: Mid Spd: K

*ENG

[-128 to 127 / 39 / 1V/step]

062

Offset: Mid Spd: C

*ENG

[-128 to 127 / 39 / 1V/step]

063

Offset: Mid Spd: M

*ENG

[-128 to 127 / 39 / 1V/step]

064

Offset: Mid Spd: Y

*ENG

[-128 to 127 / 39 / 1V/step]

071

Offset: Low Spd: K

*ENG

[-128 to 127 / 39 / 1V/step]

072

Offset: Low Spd: C

*ENG

[-128 to 127 / 39 / 1V/step]

073

Offset: Low Spd: M

*ENG

[-128 to 127 / 39 / 1V/step]

074

Offset: Low Spd: Y

*ENG

[-128 to 127 / 39 / 1V/step]



3620

[ProCon Target M/A]


001


Maximum M/A:K


*ENG

[0.250 to 0.750 / 0.370 /

0.001mg/cm2/step]

Sets solid deposit (K).

Main SP Tables-3



002


Maximum M/A:C


*ENG

[0.250 to 0.750 / 0.400 /

0.001mg/cm2/step]

Sets solid deposit (C).


003


Maximum M/A:M


*ENG

[0.250 to 0.750 / 0.450 /

0.001mg/cm2/step]

Sets solid deposit (M).


004


Maximum M/A:Y


*ENG

[0.250 to 0.750 / 0.400 /

0.001mg/cm2/step]

Sets solid deposit (Y).




3621

[Backgroud Pot:Set]

 Sets background potential

 Default: 100V, carrier deposit will occur when setting value too high.

001

Slope:K

*ENG


[-1000 to 1000 / 0 / 1/step]

002

Slope:C

*ENG

003

Slope:M

*ENG

004

Slope:Y

*ENG

011

intercept:K

*ENG


[0 to 255 / 120 / 1V/step]

012

intercept:C

*ENG

013

intercept:M

*ENG

014

intercept:Y

*ENG


3621

[Backgroud Pot:Set]

Sets background potential. (Upper/lower limit).

051

UpperLimit

*ENG

[100 to 1000 / 150 / 1V/step]

052

LowerLimit

*ENG

[0 to 100 / 100 / 1V/step]



3622

[Dev Pot :Set]

001

Current:K

*ENG

[0 to 800 / 0 / 1V/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



Displays Development Potential: Current Value (K).


002

Current:C

*ENG

[0 to 800 / 0 / 1V/step]

Displays Development Potential: Current Value (C).


003

Current:M

*ENG

[0 to 800 / 0 / 1V/step]

Displays Development Potential: Current Value (M).


004

Current:Y

*ENG

[0 to 800 / 0 / 1V/step]

Displays Development Potential: Current Value (Y).


011

Current:F_K

*ENG

[0 to 800 / 0 / 1V/step]

Displays Development Potential: Target Value (K).


012

Current:F_C

*ENG

[0 to 800 / 0 / 1V/step]

Displays Development Potential: Target Value (C).


013

Current:F_M

*ENG

[0 to 800 / 0 / 1V/step]

Displays Development Potential: Target Value (M).


014

Current:F_Y

*ENG

[0 to 800 / 0 / 1V/step]

Displays Development Potential: Target Value (Y).


021

Current:C_K

ENG

[0 to 800 / 0 / 1V/step]

Displays develop potential (K).


022

Current:C_C

ENG

[0 to 800 / 0 / 1V/step]

Displays develop potential (C).


023

Current:C_M

ENG

[0 to 800 / 0 / 1V/step]

Displays develop potential (M).


024

Current:C_Y

ENG

[0 to 800 / 0 / 1V/step]

Displays develop potential (Y).


031

Current:R_K

ENG

[0 to 800 / 0 / 1V/step]

Displays develop potential (K).

032

Current:R_C

ENG

[0 to 800 / 0 / 1V/step]

Main SP Tables-3



Displays develop potential (C).


033

Current:R_M

ENG

[0 to 800 / 0 / 1V/step]

Displays develop potential (M).


034

Current:R_Y

ENG

[0 to 800 / 0 / 1V/step]

Displays develop potential (Y).


051

UpperLimit

*ENG

[400 to 800 / 700 / 1V/step]

Sets Development Potential (Upper Limit) (K).


052

UpperLimit

*ENG

[400 to 800 / 700 / 1V/step]

Sets Development Potential (Upper Limit) (C).


053

UpperLimit

*ENG

[400 to 800 / 700 / 1V/step]

Sets Development Potential (Upper Limit) (M).


054

UpperLimit

*ENG

[400 to 800 / 700 / 1V/step]

Sets Development Potential (Upper Limit) (Y).


061

LowerLimit

*ENG

[0 to 400 / 200 / 1V/step]

Sets Development Potential (Lower Limit) (K).


062

LowerLimit

*ENG

[0 to 400 / 200 / 1V/step]

Sets Development Potential (Lower Limit) (C).


063

LowerLimit

*ENG

[0 to 400 / 200 / 1V/step]

Sets Development Potential (Lower Limit) (M).


064

LowerLimit

*ENG

[0 to 400 / 200 / 1V/step]

Sets Development Potential (Lower Limit) (Y).


101

Target:K

*ENG

[0 to 800 / 0 / 1V/step]

Displays Development Potential: Current Value (K) according to paper.


102

Target:C

*ENG

[0 to 800 / 0 / 1V/step]

Displays Development Potential: Current Value (C) according to paper.

103

Target:M

*ENG

[0 to 800 / 0 / 1V/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



Displays Development Potential: Current Value (M) according to paper.


104

Target:Y

*ENG

[0 to 800 / 0 / 1V/step]

Displays Development Potential: Current Value (Y) according to paper.


111

Target Corr:K

*ENG

[-128 to 127 / 0 / 1/step]

Displays develop potential target value correction amount (K).


112

Target Corr:C

*ENG

[-128 to 127 / 0 / 1/step]

Displays develop potential target value correction amount (C).


113

Target Corr:M

*ENG

[-128 to 127 / 0 / 1/step]

Displays develop potential target value correction amount (M).


114

Target Corr:Y

*ENG

[-128 to 127 / 0 / 1/step]

Displays develop potential target value correction amount (Y).


121

Vk:Upper_K

*ENG

[0 to 255 / 30 / 1-V/step]

Regulates upper limit of start developing voltage value (K).


122

Vk:Upper_Col

*ENG

[0 to 255 / 30 / 1-V/step]

Regulates upper limit of start developing voltage value (Col).


123

Vk:Lower_K

*ENG

[-128 to 0 / -90 / 1-V/step]

Regulates lower limit of start developing voltage value (K).


124

Vk:Lower_Col

*ENG

[-128 to 0 / -60 / 1-V/step]

Regulates lower limit of start developing voltage value (Col).




3623

[LD Power :Set]

Sets background potential

 Default: 100V

 Carrier deposit will occur when setting value too high.

001

Std Speed Slope:K

*ENG


[-1000 to 1000 / D146, D147: 213,

D148: 221, D149, D150: 233 /

1/step]

002

Std Speed Slope:C

*ENG

003

Std Speed Slope:M

*ENG

Main SP Tables-3


004

Std Speed Slope:Y

*ENG


011

Std Speed intercept:K

*ENG


[-1000 to 1000 / -18 / 1/step]

012

Std Speed intercept:C

*ENG

013

Std Speed intercept:M

*ENG

014

Std Speed intercept:Y

*ENG

021

Mid Speed Slope:K

*ENG


[-1000 to 1000 / 213 / 1/step]

022

Mid Speed Slope:C

*ENG

023

Mid Speed Slope:M

*ENG

024

Mid Speed Slope:Y

*ENG

031

Mid Speed intercept:K

*ENG


[-1000 to 1000 / -15 / 1/step]

032

Mid Speed intercept:C

*ENG

033

Mid Speed intercept:M

*ENG

034

Mid Speed intercept:Y

*ENG

041

Low Speed Slope:K

*ENG


[-1000 to 1000 / 204 / 1/step]

042

Low Speed Slope:C

*ENG

043

Low Speed Slope:M

*ENG

044

Low Speed Slope:Y

*ENG

051

Low Speed intercept:K

*ENG


[-1000 to 1000 / -15 / 1/step]

052

Low Speed intercept:C

*ENG

053

Low Speed intercept:M

*ENG

054

Low Speed intercept:Y

*ENG



3624

[TC Adj. Mode]


001


Target(Upp Limit)


*ENG

[0.00 to 1.00 / 0.15 / 0.01

mg/cm2/-kV/step]

Sets Development gamma Adjustment Target (Upp Limit) for Toner Density Adjustment.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



002


Target(Lwr Limit)


*ENG

[-1 to 0.00 / -0.15 / 0.01

mg/cm2/-kV/step]

Sets Development gamma Adjustment Target (Lwr Limit) for Toner Density Adjustment.


005


Force Consume Threshold


*ENG

[1.00 to 6.00 / 1.50 / 0.01

mg/cm2/-kV/step]

Sets Force Consume Threshold for Density Adjustment.


006

Consume(Upp Limit)

*ENG

[10 to 2550 / 294 / 1cm^2]

Sets Consume (Upp Limit) for Density Adjustment.


007

Consume(Upp Limit)

*ENG

[0 to 255 / 20 / 1times/step]

Sets Consume (Upp Limit) for Density Adjustment.


008


Force Supply Threshold


*ENG

[0.00 to 1.00 / 0.50 / 0.01

mg/cm2/-kV/step]

Sets Force Consume Threshold for Density Adjustment.


009

Supply(Upp Limit)

*ENG

[0.0 to 50.0 / 3.0 / 0.1g/step]

Sets Supply (Upp Limit) for Density Adjustment.


010

Supply(Lwr Limit)

*ENG

[0.0 to 50.0 / 1.0 / 0.1g/step]

Sets Supply (Lwr Limit) for Density Adjustment.

021

Consumption Pat: DUTY: K

*ENG


[0 to 15 / 15 / 1/step]

022

Consumption Pat: DUTY: C

*ENG

023

Consumption Pat: DUTY: M

*ENG

024

Consumption Pat: DUTY: Y

*ENG

3624

[TC Adj. Mode]


031

Max Counts:PowerON

*ENG

[0 to 50 / 0 / 1/step]

Sets consume counts (upper limit) for toner density adjusting Pro-Con.


3624

[TC Adj. Mode]

Sets adjust counts for toner density adjusting Pro-Con.

Main SP Tables-3


033

Max Counts:Printing

*ENG


[0 to 50 / 0 / 1/step]

034

Max Counts:Job End

*ENG

035

Max Counts:ACC

*ENG


[0 to 50 / 3 / 1/step]

036

Max Counts:Initial Setting

*ENG

037

Max Counts:Replenishment

*ENG

038

Max Counts:Recovery

*ENG


3624

[TC Adj. Mode]

Sets execute threshold for density adjust Pro-Con against absolute humidity.


071


AbsHumThresh(Upp)


*ENG

[0.00 to 100.00 / 16.00 /

0.01g/m3/step]

072

AbsHumThresh(Low)

*ENG

[0.00 to 100.00 / 4.00 / 0.01g/m3/step]


073


AbsHumThresh(Range)


*ENG

[0.00 to 100.00 / 12.00 /

0.01g/m3/step]




3627

[P Pattern Extraction :Set]

Sets edge detect threshold for ID sensor.


001

Edge Detection Threshold :K


*ENG


[0.0 to 5.0 / 2.5 / 0.1V/step]


002

Edge Detection Threshold :C


*ENG


003

Edge Detection Threshold :M


*ENG


004

Edge Detection Threshold :Y


*ENG


011

Edge Upper Limit:Potential Control


*ENG


[7.0 to 10.0 / 9.0 / 0.1mm/step]

Sets upper limit value of edge interval sampling count of P pattern by electric potential control.

(Processes an error when exceeding upper limit)

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



012

Edge Upper Limit:IBACC

*ENG

[10.0 to 13.0 / 12.0 / 0.1mm/step]

Sets upper limit value of edge interval sampling count of P pattern by IBACC. (Processes an error when exceeding upper limit)

013

Edge Upper Limit:RTP


[50 to 80 / 70 / 0.1mm/step]


021

Edge Lower Limit:Potential Control


*ENG


[4.0 to 7.0 / 5.0 / 0.1mm/step]

Sets lower limit value of edge interval sampling count of P pattern by electric potential control. (Keeps searching when below lower limit value)


022

Edge Lower Limit:IBACC

*ENG

[7.0 to 10.0 / 8.0 / 0.1mm/step]

Sets lower limit value of edge interval sampling count of P pattern IBACC. (Keeps searching when below lower limit value)


023

Edge Lower Limit:RTP

*ENG

[2.0 to 5.0 / 3.0 / 0.1mm/step]

Sets lower limit value of edge interval sampling count of P pattern RTP. (Keeps searching when below lower limit value)



3628

[ID Pattern Timing :Set]


001

Scan: YCMK

*ENG

[-500.0 to 500.0 / 0.0 / 0.1mm/step]

Adjusts timing of Pro-Con pattern detect by P sensor.


002

Detection Delay Time

*ENG

[0 to 2500 / 0 / 1msec/step]

Adjusts alienation start timing of paper transfer.


003

Delay Time

*ENG

[0 to 2500 / 778 / 1msec/step]

Adjusts start write timing of P pattern.


004

MUSIC Delay Time

*ENG

[0 to 2500 / 150 / 1msec/step]

Adjusts start write timing of MUSIC.

Main SP Tables-3




3629

[ProCon Pattern:Set]

Sets imaging conditions for electric potential control pattern.

001

ChargeDC: Pattern1: Bk

*ENG

[0 to 999 / 170 / 1V/step]

002

ChargeDC: Pattern2: Bk

*ENG

[0 to 999 / 210 / 1V/step]

003

ChargeDC: Pattern3: Bk

*ENG

[0 to 999 / 250 / 1V/step]

004

ChargeDC: Pattern4: Bk

*ENG

[0 to 999 / 290 / 1V/step]

005

ChargeDC: Pattern5: Bk

*ENG

[0 to 999 / 330 / 1V/step]

006

ChargeDC: Pattern6: Bk

*ENG

[0 to 999 / 370 / 1V/step]

007

ChargeDC: Pattern7: Bk

*ENG

[0 to 999 / 410 / 1V/step]

008

ChargeDC: Pattern8: Bk

*ENG

[0 to 999 / 450 / 1V/step]

009

ChargeDC: Pattern9: Bk

*ENG

[0 to 999 / 490 / 1V/step]

010

ChargeDC: Pattern10: Bk

*ENG

[0 to 999 / 530 / 1V/step]

011

ChargeDC: Pattern1: C

*ENG

[0 to 999 / 170 / 1V/step]

012

ChargeDC: Pattern2: C

*ENG

[0 to 999 / 230 / 1V/step]

013

ChargeDC: Pattern3: C

*ENG

[0 to 999 / 290 / 1V/step]

014

ChargeDC: Pattern4: C

*ENG

[0 to 999 / 350 / 1V/step]

015

ChargeDC: Pattern5: C

*ENG

[0 to 999 / 410 / 1V/step]

016

ChargeDC: Pattern6: C

*ENG

[0 to 999 / 470 / 1V/step]

017

ChargeDC: Pattern7: C

*ENG

[0 to 999 / 530 / 1V/step]

018

ChargeDC: Pattern8: C

*ENG

[0 to 999 / 590 / 1V/step]

019

ChargeDC: Pattern9: C

*ENG

[0 to 999 / 650 / 1V/step]

020

ChargeDC: Pattern10: C

*ENG

[0 to 999 / 710 / 1V/step]

021

ChargeDC: Pattern1: M

*ENG

[0 to 999 / 170 / 1V/step]

022

ChargeDC: Pattern2: M

*ENG

[0 to 999 / 230 / 1V/step]

023

ChargeDC: Pattern3: M

*ENG

[0 to 999 / 290 / 1V/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


024

ChargeDC: Pattern4: M

*ENG

[0 to 999 / 350 / 1V/step]

025

ChargeDC: Pattern5: M

*ENG

[0 to 999 / 410 / 1V/step]

026

ChargeDC: Pattern6: M

*ENG

[0 to 999 / 470 / 1V/step]

027

ChargeDC: Pattern7: M

*ENG

[0 to 999 / 530 / 1V/step]

028

ChargeDC: Pattern8: M

*ENG

[0 to 999 / 590 / 1V/step]

029

ChargeDC: Pattern9: M

*ENG

[0 to 999 / 650 / 1V/step]

030

ChargeDC: Pattern10: M

*ENG

[0 to 999 / 710 / 1V/step]

031

ChargeDC: Pattern1: Y

*ENG

[0 to 999 / 170 / 1V/step]

032

ChargeDC: Pattern2: Y

*ENG

[0 to 999 / 230 / 1V/step]

033

ChargeDC: Pattern3: Y

*ENG

[0 to 999 / 290 / 1V/step]

034

ChargeDC: Pattern4: Y

*ENG

[0 to 999 / 350 / 1V/step]

035

ChargeDC: Pattern5: Y

*ENG

[0 to 999 / 410 / 1V/step]

036

ChargeDC: Pattern6: Y

*ENG

[0 to 999 / 470 / 1V/step]

037

ChargeDC: Pattern7: Y

*ENG

[0 to 999 / 530 / 1V/step]

038

ChargeDC: Pattern8: Y

*ENG

[0 to 999 / 590 / 1V/step]

039

ChargeDC: Pattern9: Y

*ENG

[0 to 999 / 650 / 1V/step]

040

ChargeDC: Pattern10: Y

*ENG

[0 to 999 / 710 / 1V/step]

101

DevelopmentDC: Pattern1: Bk

*ENG

[0 to 999 / 50 / 1V/step]

102

DevelopmentDC: Pattern2: Bk

*ENG

[0 to 999 / 90 / 1V/step]

103

DevelopmentDC: Pattern3: Bk

*ENG

[0 to 999 / 130 / 1V/step]

104

DevelopmentDC: Pattern4: Bk

*ENG

[0 to 999 / 170 / 1V/step]

105

DevelopmentDC: Pattern5: Bk

*ENG

[0 to 999 / 210 / 1V/step]

106

DevelopmentDC: Pattern6: Bk

*ENG

[0 to 999 / 250 / 1V/step]

107

DevelopmentDC: Pattern7: Bk

*ENG

[0 to 999 / 290 / 1V/step]

108

DevelopmentDC: Pattern8: Bk

*ENG

[0 to 999 / 330 / 1V/step]

109

DevelopmentDC: Pattern9: Bk

*ENG

[0 to 999 / 370 / 1V/step]

Main SP Tables-3



110

DevelopmentDC: Pattern10: Bk


*ENG


[0 to 999 / 410 / 1V/step]

111

DevelopmentDC: Pattern1: C

*ENG

[0 to 999 / 50 / 1V/step]

112

DevelopmentDC: Pattern2: C

*ENG

[0 to 999 / 110 / 1V/step]

113

DevelopmentDC: Pattern3: C

*ENG

[0 to 999 / 170 / 1V/step]

123

DevelopmentDC: Pattern3: M

*ENG

[0 to 999 / 170 / 1V/step]

124

DevelopmentDC: Pattern4: M

*ENG

[0 to 999 / 230 / 1V/step]

125

DevelopmentDC: Pattern5: M

*ENG

[0 to 999 / 290 / 1V/step]

133

DevelopmentDC: Pattern3: Y

*ENG

[0 to 999 / 170 / 1V/step]

134

DevelopmentDC: Pattern4: Y

*ENG

[0 to 999 / 230 / 1V/step]

135

DevelopmentDC: Pattern5: Y

*ENG

[0 to 999 / 290 / 1V/step]

136

DevelopmentDC: Pattern6: Y

*ENG

[0 to 999 / 350 / 1V/step]

137

DevelopmentDC: Pattern7: Y

*ENG

[0 to 999 / 410 / 1V/step]

138

DevelopmentDC: Pattern8: Y

*ENG

[0 to 999 / 470 / 1V/step]

139

DevelopmentDC: Pattern9: Y

*ENG

[0 to 999 / 530 / 1V/step]


140

DevelopmentDC: Pattern10: Y


*ENG


[0 to 999 / 590 / 1V/step]



3630

[Dev gamma :Disp/Set]


001


Current:K


*ENG

[0.10 to 6.00 / 0.95 / 0.01

mg/cm2/-kV/step]

Displays the latest Development gamma (K).


002


Current:C


*ENG

[0.10 to 6.00 / 0.95 / 0.01

mg/cm2/-kV/step]

Displays the latest Development gamma (C).


003


Current:M


*ENG

[0.10 to 6.00 / 1.05 / 0.01

mg/cm2/-kV/step]

Displays the latest Development gamma (M).

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



004


Current:Y


*ENG

[0.10 to 6.00 / 0.95 / 0.01

mg/cm2/-kV/step]

Displays the latest Development gamma (Y).


011


Target:K


*ENG

[0.50 to 2.55 / 0.95 / 0.01

mg/cm2/-kV/step]

Displays Target Value for Development gamma (K).

Displays environment correction amount of develop gamma.


042


Environ Corr:Col


*ENG

[-1.00 to 1.00 / 0.00 / 0.01

mg/cm2/-kV/step]

Displays environment correction amount of develop gamma.


051


TnrDensity Corr:K


*ENG

[-1.00 to 1.00 / 0.00 / 0.01

mg/cm2/-kV/step]

Displays toner density correction amount of develop gamma. (K)


052


TnrDensity Corr:C


*ENG

[-1.00 to 1.00 / 0.00 / 0.01

mg/cm2/-kV/step]

Displays toner density correction amount of develop gamma. (C)


053


TnrDensity Corr:M


*ENG

[-1.00 to 1.00 / 0.00 / 0.01

mg/cm2/-kV/step]

Displays toner density correction amount of develop gamma. (M)


054


TnrDensity Corr:Y


*ENG

[-1.00 to 1.00 / 0.00 / 0.01

mg/cm2/-kV/step]

Displays toner density correction amount of develop gamma. (Y)


061

TnrDensity:K

*ENG

[0.0 to 25.5 / 0.0 / 0.1 wt%/step]

Displays Toner Density (K) converted based on TD Sensor output.


062

TnrDensity:C

*ENG

[0.0 to 25.5 / 0.0 / 0.1 wt%/step]

Displays Toner Density (C) converted based on TD Sensor output.


063

TnrDensity:M

*ENG

[0.0 to 25.5 / 0.0 / 0.1 wt%/step]

Displays Toner Density (M) converted based on TD Sensor output.

Main SP Tables-3



064

TnrDensity:Y

*ENG

[0.0 to 25.5 / 0.0 / 0.1 wt%/step]

Displays Toner Density (Y) converted based on TD Sensor output.


071


Environ Corr1:K


*ENG

[-1.00 to 1.00 / 0.00 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 1) of develop gamma.


072


Environ Corr2:K


*ENG

[-1.00 to 1.00 / 0.04 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 2) of develop gamma.


073


Environ Corr3:K


*ENG

[-1.00 to 1.00 / 0.06 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 3) of develop gamma.


074


Environ Corr4:K


*ENG

[-1.00 to 1.00 / 0.08 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 4) of develop gamma.


075


Environ Corr5:K


*ENG

[-1.00 to 1.00 / 0.10 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 5) of develop gamma.


076


Environ Corr6:K


*ENG

[-1.00 to 1.00 / 0.10 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 6) of develop gamma


081


Environ Corr1:Col


*ENG

[-1.00 to 1.00 / 0.00 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 1) of develop gamma.

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



082


Environ Corr2:Col


*ENG

[-1.00 to 1.00 / 0.04 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 2) of develop gamma.


083


Environ Corr3:Col


*ENG

[-1.00 to 1.00 / 0.06 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 3) of develop gamma.


084


Environ Corr4:Col


*ENG

[-1.00 to 1.00 / 0.08 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 4) of develop gamma.


085


Environ Corr5:Col


*ENG

[-1.00 to 1.00 / 0.10 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 5) of develop gamma.


086


Environ Corr6:Col


*ENG

[-1.00 to 1.00 / 0.10 / 0.01

mg/cm2/-kV/step]

Sets environment correction table value (environment section 6) of develop gamma.


090

TC-Gamma

*ENG

[0.10 to 0.25 / 0.20 / 0.01/step]

Slope of TC-develop gamma.


091

TC Corr ThreshHold:K

*ENG

[7.0 to 12.0 / 9.0 / 0.1wt%/step]

Sets toner density threshold for correction using TC correction term of develop gamma (target).


092

TC Corr ThreshHold:C

*ENG

[7.0 to 12.0 / 9.0 / 0.1wt%/step]

Sets toner density threshold for correction using TC correction term of develop gamma (target).

093

TC Corr ThreshHold:M

*ENG

[7.0 to 12.0 / 9.0 / 0.1wt%/step]

Main SP Tables-3



Sets toner density threshold for correction using TC correction term of develop gamma (target).


094

TC Corr ThreshHold:Y

*ENG

[7.0 to 12.0 / 9.0 / 0.1wt%/step]

Sets toner density threshold for correction using TC correction term of develop gamma (target).

3630

[Dev gamma :Disp/Set]


101


UpperLimit


*ENG

[1.00 to 5.00 / 5.00 /

0.01mg/cm2/-kV/step]

Displays initial value of develop gamma (K).


102


LowerLimit


*ENG

[0.10 to 1.00 / 0.15 /

0.01mg/cm2/-kV/step]

Displays initial value of develop gamma (C).


3630

[Dev gamma :Disp/Set]

Displays latest develop gamma.


111


Current:F_K


ENG

[0.10 to 6.00 / 0.90 /

0.01mg/cm2/-kV/step]

112

Current:F_C

ENG


[0.10 to 6.00 / 0.80 /

0.01mg/cm2/-kV/step]

113

Current:F_M

ENG

114

Current:F_Y

ENG


121


Current:C_K


ENG

[0.10 to 6.00 / 0.90 /

0.01mg/cm2/-kV/step]

122

Current:C_C

ENG


[0.10 to 6.00 / 0.80 /

0.01mg/cm2/-kV/step]

123

Current:C_M

ENG

124

Current:C_Y

ENG


131


Current:R_K


ENG

[0.10 to 6.00 / 0.90 /

0.01mg/cm2/-kV/step]

132

Current:R_C

ENG


[0.10 to 6.00 / 0.80 /

0.01mg/cm2/-kV/step]

133

Current:R_M

ENG

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


134

Current:R_Y

ENG



3630

[Dev gamma :Disp/Set]

Regulates valid deposit amount range for calculating develop gamma.


141


Range M/A Upp:K


*ENG

[0.20 to 1.00 / 0.40 /

0.01mg/cm2/step]


142


Range M/A Low:K


*ENG

[0.00 to 0.20 / 0.05 /

0.01mg/cm2/step]


143


Range M/A Upp:Col


*ENG

[0.20 to 1.00 / 0.50 /

0.01mg/cm2/step]


144


Range M/A Low:Col


*ENG

[0.00 to 0.20 / 0.05 /

0.01mg/cm2/step]




3631

[Vk :Disp]

Displays latest develop start voltage.

001

Current:K

*ENG


[-300 to 300 / 0 / 1-V/step]

002

Current:C

*ENG

003

Current:M

*ENG

004

Current:Y

*ENG

111

Current:F_K

ENG


[-300 to 300 / 0 / 1-V/step]

112

Current:F_C

ENG

113

Current:F_M

ENG

114

Current:F_Y

ENG

121

Current:C_K

ENG


[-300 to 300 / 0 / 1-V/step]

122

Current:C_C

ENG

123

Current:C_M

ENG

124

Current:C_Y

ENG

131

Current:R_K

ENG

[-300 to 300 / 0 / 1-V/step]

Main SP Tables-3


132

Current:R_C

ENG


133

Current:R_M

ENG

134

Current:R_Y

ENG



3650

[APC: Set]


001

Interval

*ENG

[0 to 200 / 0 / 1page/step]

Sets executing interval of electric potential control during printing.


3650

[APC: Set]

Sets deposit amount threshold (upper/lower limit) to start supplying with supply gain 3 of electric potential control during print.

011

Page Cnt:K

*ENG

[0 to 200 / 0 / 1pages/step]

012

Page Cnt:C


[0 to 200 / 0 / 1pages/step]

013

Page Cnt:M


[0 to 200 / 0 / 1pages/step]

014

Page Cnt:Y


[0 to 200 / 0 / 1pages/step]


021


Maximum M/A Corr:K


[-150.000 to 150.000 / 1.000 /

0.001mg/cm2/step]


022


Maximum M/A Corr:C


[-150.000 to 150.000 / 1.000 /

0.001mg/cm2/step]


023


Maximum M/A Corr:M


[-150.000 to 150.000 / 1.000 /

0.001mg/cm2/step]


024


Maximum M/A Corr:Y


[-150.000 to 150.000 / 1.000 /

0.001mg/cm2/step]


031


M/A UpperLimit2:K


*ENG

[0.000 to 0.100 / 0.020 /

0.001mg/cm2/step]

032

M/A UpperLimit2:C

*ENG


[0.000 to 0.100 / 0.020 /

0.001mg/cm2/step]

033

M/A UpperLimit2:M

*ENG

034

M/A UpperLimit2:Y

*ENG

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3



041


M/A LowerLimit2:K


*ENG

[0.000 to 0.100 / 0.020 /

0.001mg/cm2/step]

042

M/A LowerLimit2:C

*ENG


[0.000 to 0.100 / 0.020 /

0.001mg/cm2/step]

043

M/A LowerLimit2:M

*ENG

044

M/A LowerLimit2:Y

*ENG

3650

[APC: Set]


051

Corr Gain(GAMMA)

*ENG

[0 to 99 / 5 / 1/step]

Sets correction gain 1 of electric potential control during printing.


052

Corr Gain(ASSIST)

*ENG

[0 to 99 / 4 / 1/step]

Sets correction gain 2 of electric potential control during printing.


053

Corr Gain(ADJUST)

*ENG

[0 to 99 / 6 / 1/step]

Sets correction gain 3 of electric potential control during printing.


054

Corr3MaxCnt

*ENG

[0 to 99 / 30 / 1time/step]

Sets correction times for correction gain 3 of electric potential control during printing.


055

Interval Coef

*ENG

[0.0 to 1.0 / 0.5 / 0.1/step]

Correction coefficient to correct Paper interval P pattern create interval.


056

ADJUSTMaxCnt

*ENG

[0 to 99 / 5 / 1time/step]

Sets correction times for ASSIST of electric potential control during printing.


3650

[APC: Set]

Sets execution flag for correction gain 3 of electric potential control during printing.

061

ADJUST Flag:K

*ENG


[0 or 1 / 0 / 1/step]

062

ADJUST Flag:C

*ENG


3650

[APC: Set]

Displays execution times counter for correction gain 3 of electric potential control during printing.

Main SP Tables-3


071

ADJUST Exe Cnt:K

*ENG


[0 to 99 / 0 / 1pages]

072

ADJUST Exe Cnt:C

*ENG

073

ADJUST Exe Cnt:M

*ENG

074

ADJUST Exe Cnt:Y

*ENG


3650

[APC: Set]

Sets delta Vt value to decide Vt threshold of electric potential during printing.

081

Vt Thresh:Range:K

*ENG


[0.00 to 1.00 / 0.20 / 0.01V/step]

082

Vt Thresh:Range:C

*ENG

083

Vt Thresh:Range:M

*ENG

084

Vt Thresh:Range:Y

*ENG

3650

[APC: Set]


101

limit:LDP

*ENG

[0 to 10 / 10 / 1%/step]

Upper limit threshold for LDP variable amount of APC.


102

limit:Bias

*ENG

[0 to 30 / 10 / 1V/step]

Upper limit threshold for bias variable amount of APC.




3660

[IBACC:Disp/Set]

Density target value per IBACC pattern.

001

TargetValue:K_P1

*ENG

[0 to 1023 / 869 / 1/step]

002

TargetValue:K_P2

*ENG

[0 to 1023 / 702 / 1/step]

003

TargetValue:K_P3

*ENG

[0 to 1023 / 522 / 1/step]

004

TargetValue:K_P4

*ENG

[0 to 1023 / 323 / 1/step]

005

TargetValue:K_P5

*ENG

[0 to 1023 / 196 / 1/step]

006

TargetValue:K_P6

*ENG

[0 to 1023 / 254 / 1/step]

021

TargetValue:C_P1

*ENG

[0 to 1023 / 965 / 1/step]

022

TargetValue:C_P2

*ENG

[0 to 1023 / 909 / 1/step]

SP Mode Tables

SP Mode Tables

SP Mode Tables

Main SP Tables-3


023

TargetValue:C_P3

*ENG

[0 to 1023 / 832 / 1/step]



3800

[Waste Toner Full Detection]


022


Background M/A


[0 to 1000000 / 20 /

0.000001mg/mm2/step]

023

Percentage of Transfer Ratio


[0 to 1000 / 810 / 0.1%/step]


024

Date of detection for near full

*ENG

[0 or 1 / 0 / 1/step]

Displays latest date done mechanical detect.



3810

[Lubricant End Detection]


001


Near End Detection Distance: Thres1:Bk


*ENG

[0 to 999999999 / D146,D147:

0, D148,D149,D150: 689336 /

1cm/step]

*No use for this machine.

Rotation distance threshold: Bk from near end detect to near end detect 2.


003

End Detection Distance: Thres2:Bk


*ENG

[0 to 999999999 / 689336 /

1cm/step]

*No use for this machine.

Rotation distance threshold: Bk from near end detect to end detect.


011

Conduction Detection Times Counter:K


*ENG


[0 to 9 / 0 / 1/step]

*No use for this machine.

Accumulation of continues detecting times.


015

Near End Distance:K

*ENG

[0 to 999999999 / 0 / 1cm/step]

*No use for this machine.

PCU rotation distance of when detecting near end: saving SP


021


Detection Flag:K


*ENG

[0 to 3 / 0 / 1/step]

0: Undetected

1: mechanically detected 2: Near end detected

3: End detected.

Main SP Tables-3



*No use for this machine. Detect flag


025


New Unit Detection Flag:K


*ENG

[0 or 1 / 0 / 1/step]

0: Normal state

1: New article detected

*No use for this machine. New article detect flag



3894

[Engine Counter Clear]

001

Mainframe SP


[0 or 1 / 0 / 1/step]

002

AIT-ID chip


[0 or 1 / 0 / 1/step]

003

Toner tag


[0 or 1 / 0 / 1/step]

004

All


[0 or 1 / 0 / 1/step]




3905

[Recycled Parts: New/Old Flag]

Sets a flag able to recognize whether PCU is New or recycled per machine unit. (Set to "1" for recycled)

001

OPC:K

*ENG


[0 or 1 / 0 / 1/step]

002

OPC:C

*ENG

003

OPC:M

*ENG

004

OPC:Y

*ENG

 

SP3-XXX (PROCESS)