Electrical component
Item | D146/D147/D148/D149/D150 | Predecessor | Purpose |
LCD | Two types of LCD (not compatible each other) | One type of LCD | Multi vender system |
IOB | Two IOB’s for image creation and paper transfer | One IOB | Optimized layout |
NVRAM | Two EEPROM’s | One | |
Flat Flexible Cable (FFC) | FFC used for main sigle line FFC with clip socket | Wire harness FFC without clip | Weight saving Handle ability improvement |
Main switch | DC SW Press and hold = forced OFF | Locker SW The plug must be pulled out for forced OFF. | (component change) |
FAX | Bracket added in the replacement FCU part | No bracket for FCU to hold | Handle ability improvement |
1.4.2 NEW FEATURES OF D146/D147/D148/D149/D150
Item | Description |
Android operation panel | Android OS built in Simple UI for copy, scanner and FAX Advanced operational feeling |
Searchable PDF (SD card option) | Scan function to add text information in the scan file |
Image area extension option (paper transfer roller) | Wider paper transfer roller Real time process control deactivation is required. |
Log trace function | Enhancement for controller and engine log correction function |