HOME PAGE | < Previous | Contents | Next >
8. Heating sleeve belt unit [A] ×4)
Replacement and Adjustment
Replacement and Adjustment
Replacement and Adjustment
4.12.9 PRESSURE ROLLER
Adjustment before replacing the pressure roller
Before replacing the Pressure Roller, set SP3-701-118 to "1" and switch the power OFF. Then replace the Pressure Roller and switch the power ON.
Replacement
Do not remove or adjust the pressure adjusting screws [A] when replacing the pressure roller.
The fusing unit is adjusted in the factory to match the hardness of the pressure roller, so that the nip width will be correct, so please do not release the pressure adjustment screw.
Fusing Unit
This screw is adjusted in the factory for the correct nip width, to match the hardness characteristics of each roller. Do not adjust the pressure adjustment screw in the field.
Also, do not move the pressure roller to another fusing unit.
1. Heating sleeve belt unit (Heating sleeve belt unit)
2. Pressure roller [A] ×2)
3. Apply the grease (FLUOTRIBO MG GREASE) to the rear shaft of the pressure roller at 5-7mm from the cut edge.