HOME PAGE | < Previous | Contents | Next >

Image Transfer Unit


SP No.

Classification 1

Classification 2

Value


3-334-006


ID.Sens TestVal:C

Vct_dif Check:Xint


TM/P sensor: C, value of [6]

3-335-001

ID.Sens TestVal:R

K2: Check

TM/P sensor: R, value of [1]

3-335-002

ID.Sens TestVal:R

Diffuse Corr

TM/P sensor: R, value of [2]


3-335-003


ID.Sens TestVal:R

Vct_reg Check:Slope


TM/P sensor: R, value of [3]


3-335-004


ID.Sens TestVal:R

Vct_reg Check:Xint


TM/P sensor: R, value of [4]


3-335-005


ID.Sens TestVal:R

Vct_dif Check:Slope


TM/P sensor: R, value of [5]


3-335-006


ID.Sens TestVal:R

Vct_dif Check:Xint


TM/P sensor: R, value of [6]


Replacement procedure

1. Image transfer belt unit (page 4-65 "Image Transfer Belt Unit")

2. Paper transfer roller unit (page 4-73 "Paper Transfer Roller Unit ")

3. Fusing unit (page 4-99 "Fusing Unit")

4. Fusing dowser position sensor unit (page 4-110 "Fusing Shield Position Sensor")

5. TM(ID) sensor unit [A] image×2, image×3, image×5)

image

When installing the TM / ID sensor unit.

1. Attach the screw of the front side [B]

2. Attach the screw of the back side [C]

When installed in reverse order, an SC may occur because the sensor position has shifted.