HOME PAGE | < Previous | Contents | Next >
SP No. | Classification 1 | Classification 2 | Value |
3-334-006 | ID.Sens TestVal:C | Vct_dif Check:Xint | TM/P sensor: C, value of [6] |
3-335-001 | ID.Sens TestVal:R | K2: Check | TM/P sensor: R, value of [1] |
3-335-002 | ID.Sens TestVal:R | Diffuse Corr | TM/P sensor: R, value of [2] |
3-335-003 | ID.Sens TestVal:R | Vct_reg Check:Slope | TM/P sensor: R, value of [3] |
3-335-004 | ID.Sens TestVal:R | Vct_reg Check:Xint | TM/P sensor: R, value of [4] |
3-335-005 | ID.Sens TestVal:R | Vct_dif Check:Slope | TM/P sensor: R, value of [5] |
3-335-006 | ID.Sens TestVal:R | Vct_dif Check:Xint | TM/P sensor: R, value of [6] |
Replacement procedure
1. Image transfer belt unit (page 4-65 "Image Transfer Belt Unit")
2. Paper transfer roller unit (page 4-73 "Paper Transfer Roller Unit ")
3. Fusing unit (page 4-99 "Fusing Unit")
4. Fusing dowser position sensor unit (page 4-110 "Fusing Shield Position Sensor")
5. TM(ID) sensor unit [A] ×2,
×3,
×5)
When installing the TM / ID sensor unit.
1. Attach the screw of the front side [B]
2. Attach the screw of the back side [C]
When installed in reverse order, an SC may occur because the sensor position has shifted.