HOME PAGE | < Previous | Contents | Next >
2.13 INTERNAL SHIFT TRAY SH3070
Installation
Installation
Installation
2.13.1 ACCESSORY CHECK
No. | Description | Q’ty |
1 | Tray Cover | 1 |
2 | Lever | 1 |
3 | Sheet | 2 |
2.13.2 INSTALLATION PROCEDURE
When installing this option, turn the power to the machine off, and unplug the power plug from the wall socket.
If it is installed when the power is on, it will result in an electric shock or a malfunction.
1. Remove the filament tape and packing material.
2. Remove the enclosed items.
3. Attach the part [B] to the shift tray [A].
Internal Shift Tray SH3070
4. Paper output tray [A].
5. Connector cover [A].
6. Attach the shift tray.
Internal Shift Tray SH3070
Installation
Installation
Installation
7. Open the right cover.
8. Main power switch cover [A] ×1).
Remember that there is a claw at the positions in the blue circles.
9.
10. Remove the feeler [A].
Internal Shift Tray SH3070
11. Attach the shift tray feeler [A].
12. Attach the sheets [A] at the edge of the paper output cover.
13. Attach the paper output cover and main power switch cover, and close the duplex unit.
14. Turn the power switch ON.
15. Check that paper output to the shift tray can be selected at the operation panel, and check the operation.