5804 | [OUTPUT Check] | ||
5-804-202 | Scanner Lamp | ENG | [0 or 1 / 0 / 1/step] |
Checks output of scanner lamp. Use to check light source malfunction when SC101-01, SC101-02, SC102-00, SC142-00 occurs. | |||
5-804-206 | PTR Open/Close LED | ENG | [0 or 1 / 0 / 1/step] |
Lights paper transfer open/close LED. | |||
5-804-208 | TM/P Sensor: F | ENG | [0 or 1 / 0 / 1/step] |
Lights TM/P sensor: Front glowing part. | |||
5-804-209 | TM/P Sensor: C | ENG | [0 or 1 / 0 / 1/step] |
Lights TM/P sensor: Center glowing part. | |||
5-804-210 | TM/P Sensor: R | ENG | [0 or 1 / 0 / 1/step] |
Lights TM/P sensor: Rear glowing part. | |||
5-804-211 | Toner Sensor Power | ENG | [0 or 1 / 0 / 1/step] |
5-804-232 | Toner IDTAG Power | ENG | [0 or 1 / 0 / 1/step] |
5804 | [OUTPUT Check] | ||
5-804-239 | Fusing Exit Drive Solenoid | ENG | [0 or 1 / 0 / 1/step] |
5804 | [OUTPUT Check] | ||
Continuously drives specified motor for operation test. | |||
5-804-241 | Bank: Tray3: Feed Mt: Standard Speed | ENG | [0 or 1 / 0 / 1/step] |
5-804-242 | Bank: Tray4: Feed Mt: Standard Speed | ENG | |
5-804-243 | Bank: Tray5: Feed Mt: Standard Speed | ENG | |
5-804-244 | Bank: Tray3: Transport Mt: Standard Speed | ENG |
5-804-245 | Bank: Tray4: Transport Mt: Standard Speed | ENG | |
5-804-246 | Bank: Tray5: Transport Mt: Standard Speed | ENG | |
5804 | [OUTPUT Check] | ||
Drives specified motor for a certain period of time to test operation. | |||
5-804-247 | Bank: Tray3: PU Solenoid | ENG | [0 or 1 / 0 / 1/step] |
5-804-248 | Bank: Tray4: PU Solenoid | ENG | |
5-804-249 | Bank: Tray5: PU Solenoid | ENG |
Engine SP Mode Tables
ADF
6008 | [ADF OUTPUT Check] | ||
Checks operation of the load of ADF. | |||
6-008-003 | Feed Motor Forward | ENG | [0 or 1 / 0 / 1/step] |
Rotates paper feed motor forward. | |||
6-008-004 | Feed Motor Reverse | ENG | [0 or 1 / 0 / 1/step] |
Rotates paper feed motor backward. | |||
6-008-005 | Relay Motor Forward | ENG | [0 or 1 / 0 / 1/step] |
Rotates carry motor forward. | |||
6-008-006 | Relay Motor Reverse | ENG | [0 or 1 / 0 / 1/step] |
Rotates carry motor backward. | |||
6-008-011 | Inverter Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Interval drives reverse solenoid. | |||
6-008-012 | Stamp | ENG | [0 or 1 / 0 / 1/step] |
Interval drives DONE stamp. | |||
6-008-013 | Fan Motor | ENG | [0 or 1 / 0 / 1/step] |
Interval drives FAN motor. | |||
6-008-014 | Feed Clutch | ENG | [0 or 1 / 0 / 1/step] |
Interval drives paper feed clutch. | |||
6-008-015 | Feed Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Interval drives paper feed solenoid. |
6012 | [1-Pass ADF OUTPUT Check] | ||
For Single-Pass simultaneous duplex models only. | |||
6-012-001 | Pick-Up Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF pick up motor. | |||
6-012-003 | Feed Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF paper feed motor. | |||
6-012-005 | Relay Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF paper carry motor. | |||
6-012-009 | Exit Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF paper exit motor. | |||
6-012-010 | Bottom Plate Motor For/Rev | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Moves up/down the bottom plate by driving the ADF bottom plate motor forward, backward. |
6-012-012 | Stamp | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Stamps the DONE stamp. | |||
6-012-015 | Pull-Out Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF pull out motor. | |||
6-012-016 | Middle Motor Forward | ENG | [0 or 1 / 0 / 1/step] 0:Off 1:On |
Forwardly rotates ADF middle motor. |
Engine SP Mode Tables
Finisher
6124 | [OUTPUT Check: 2K/3K FIN] | ||
6-124-001 | Entrance Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-002 | Horizontal Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-003 | Pre-Stack Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-004 | ITB Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-005 | Paper Exit Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. |
6-124-006 | Upper Junction Solenoid | ENG | [0 or 1 / 0 / 1/step] |
Turns NO/OFF specified solenoid for validation. | |||
6-124-007 | TE Stack Plate Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-008 | Paper Exit Open/Close Guide Plate Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-009 | Punching Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-010 | Punch Move Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-011 | S-to-S Registration Detection Move Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-012 | Lower Junction Solenoid Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-013 | Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-014 | Positioning Roller Rotation Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-015 | Feed-out Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-016 | Booklet Stapler Move Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. |
6-124-017 | Corner Stapler Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-018 | Booklet Stapler Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-019 | Booklet Stapler Jog Solenoid Move Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-020 | Booklet Stapler Standard Fence Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-021 | Booklet Stapler Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-022 | Dynamic Roller Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-023 | Folder Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-025 | Press-fold Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-026 | Tray Lift Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-027 | Shift Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-028 | Front Shift Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. * Not use: currently, VOLGA-B does not have setting jogger in system configuration. |
Engine SP Mode Tables
6-124-029 | Rear Shift Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. * Not use: currently, VOLGA-B does not have setting jogger in system configuration. | |||
6-124-030 | Shift Jogger Retraction Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. * Not use: currently, VOLGA-B does not have setting jogger in system configuration. | |||
6-124-031 | Drag Roller Vibrating Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-032 | LE Guide Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-033 | Navigation LED (All) | ENG | [0 or 1 / 0 / 1/step] |
Lights all guide LED. | |||
6-124-037 | Positioning Roller Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. | |||
6-124-038 | Paper Guide Motor | ENG | [0 or 1 / 0 / 1/step] |
Drives specified motor for a certain period of time to test operation. |
6136 | [OUTPUT Check: FrontFIN] | ||
Continuously drives specified motor for operation test. | |||
6-136-001 | Entrance Motor | *ENG | [0 or 1 / 0 / 1/step] |
6-136-002 | Carry Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-003 | Exit Motor | ENG | [0 or 1 / 0 / 1/step] |
6136 | [OUTPUT Check: FrontFIN] |
Drives specified motor for a certain period of time to test operation. | |||
6-136-004 | Front Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-005 | Rear Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-006 | Shift Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-007 | Hitroll Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-008 | Exit Guide Plate Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-009 | Staple Moving Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-010 | Tray Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-011 | Staple Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-012 | Stopper Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-013 | Punch Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-014 | Punch Moving Motor | ENG | [0 or 1 / 0 / 1/step] |
6-136-015 | Punch Registration Moving Motor | ENG | [0 or 1 / 0 / 1/step] |
Engine SP Mode Tables
6162 | [FIN (1K FIN) OUTPUT Check] | ||
Continuously runs specified motor for operation test. | |||
6-162-001 | Entrance Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-002 | Proof Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-003 | Paper Feed/Positioning & Move Roller Motor | ENG | [0 or 1 / 0 / 1/step] |
6162 | [FIN (1K FIN) OUTPUT Check] | ||
Drives specified motor for a certain period of time to test operation. | |||
6-162-004 | Junction Solenoid | ENG | [0 or 1 / 0 / 1/step] |
6-162-005 | Shift Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-006 | Jogger Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-007 | Exit Guide Plate Open/Close Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-008 | Feed-out Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-009 | Tray Lift Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-011 | Positioning Roller Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-012 | Stapler Shift Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-013 | Stapler Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-014 | Untitled | ENG | [0 or 1 / 0 / 1/step] |
6-162-015 | Untitled | ENG | [0 or 1 / 0 / 1/step] |
6-162-016 | Untitled | ENG | [0 or 1 / 0 / 1/step] |
6-162-017 | Punch Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-018 | Punch Move Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-019 | S-to-S Registration Detection Move Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-020 | Stack Transport Motor: Upper | ENG | [0 or 1 / 0 / 1/step] |
6-162-021 | Stck Trns Uppr Prss Rls/Stndrd Fence Rtrct M | ENG | [0 or 1 / 0 / 1/step] |
6-162-022 | Stack Lower Pressure Release Motor | ENG | [0 or 1 / 0 / 1/step] |
6162 | [FIN (1K FIN) OUTPUT Check] | ||
Continuously runs specified motor for operation test. | |||
6-162-023 | Folder Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
6162 | [FIN (1K FIN) OUTPUT Check] | ||
Drives specified motor for a certain period of time to test operation. | |||
6-162-024 | TE Stopper Motor | ENG | [0 or 1 / 0 / 1/step] |
6-162-025 | Folder Blade Motor | ENG | [0 or 1 / 0 / 1/step] |
6162 | [FIN (1K FIN) OUTPUT Check] | ||
Lights all guide LED. | |||
6-162-026 | Navigation LED (All) | ENG | [0 or 1 / 0 / 1/step] |
Engine SP Mode Tables
6185 | [Output Check: NoStplBindFIN] | ||
6-185-001 | Transport Motor | ENG | [0 or 1 / 0 / 1/step] |
Checks the transport motor’s movement of non staple finisher. | |||
6-185-002 | Shift Motor | ENG | [0 or 1 / 0 / 1/step] |
Checks the shift motor’s movement of non staple finisher. | |||
6-185-003 | Junction Solenoid Motor | ENG | [0 or 1 / 0 / 1/step] |
Checks the junction solenoid motor’s movement of non staple finisher. | |||
6-185-004 | Exit Pressure Release Motor | ENG | [0 or 1 / 0 / 1/step] |
Checks the exit pressure release motor’s movement of non staple finisher. | |||
6-185-005 | Stapler Motor | ENG | [0 or 1 / 0 / 1/step] |
Checks the stapler motor’s movement of non staple finisher. |
Printing Test pattern: SP2-109
Some of these test patterns are used for copy image adjustments but most are used primarily for design testing.
Do not operate the machine until the test pattern is printed out completely. Otherwise, SC will occur.
Enter the SP mode then select SP2-109-003.
Select test pattern for print from the list then press [OK].
When selecting color for Printing; Full Color or either CMYK, go to SP2-109-005 (1: Full Color, 2: Cyan, 3: Magenta, 4: Yellow, 5: Black) to select.
When changing density of test pattern, select density with SP2-109-006 through 009 for each color.
If select "0" with SP2-109-006 through 009, the color adjusted so will not show up in the test pattern.
To Print, Touch "Copy Window", then set settings within the following window for test print (paper size etc…).
When using black and white printing, touch "Black & White" on the LCD. When using color printing, touch "Full Color" on the LCD.
Press "Start" key to start test print.
After checking test pattern, touch "SP Mode" on the LCD to return to SP mode display.
Reset all settings to default values.
Exit SP mode.
No. | Pattern | No. | Pattern |
0 | Copy image | 12 | Independent Pattern (2dot) |
1 | Vertical Line (1dot) | 13 | Independent Pattern (4dot) |
2 | Vertical Line (2dot) | 14 | Trimming Area |
3 | Horizontal Line (1dot) | 15 | Hound's Tooth Check (Vertical) |
4 | Horizontal Line (2dot) | 16 | Hound's Tooth Check (Horizontal) |
5 | Grid Vertical Line | 17 | Band (Horizontal) |
No. | Pattern | No. | Pattern |
6 | Grid Horizontal Line | 18 | Band (Vertical) |
7 | Grid Pattern Small | 19 | Checker Flag Pattern |
8 | Grid Pattern Large | 20 | Grayscale (Vertical Margin) |
9 | Argyle Pattern Small | 21 | Grayscale (Horizontal Margin) |
10 | Argyle Pattern Large | 22 | Wormy Pattern |
11 | Independent Pattern (1dot) | 23 | Full Dot Pattern |
Engine SP Mode Tables
RE V IS ION H IST ORY | ||
Page | Date | Added/ Updated/ New |
None |
Controller SP Mode Tables
5024
5009 | [Add Display Language] | ||
Adds language available in user choice. (Only the languages registered in the machine) Refer to the displayed language list to set in the way showed below. List Number Assigned Bit Switch No.1 to 8 BIT1 to 8 (SP5-009-201) No.9 to 16 BIT1 to 8 (SP5-009-202) No.17 to 24 BIT1 to 8 (SP5-009-203) No.25 to 32 BIT1 to 8 (SP5-009-204) No.33 to 40 BIT1 to 8 (SP5-009-205) No.41 to 48 BIT1 to 8 (SP5-009-206) No.49 to 56 BIT1 to 8 (SP5-009-207) Example: To add American(No.3 in the list) or Czech (No.15) Turn Bit 3 of “SP5-009-201” 0 to 1 for American. Turn Bit 7 of “SP5-009-202” 0 to 1 for Czech. After setting, turn the main power switch off and on to make the setting valid. | |||
5-009-201 | 1-8 | *CTL | [1 to 255 / 0 / 1] |
5-009-202 | 9-16 | *CTL | [1 to 255 / 0 / 1] |
5-009-203 | 17-24 | *CTL | [1 to 255 / 0 / 1] |
5-009-204 | 25-32 | *CTL | [1 to 255 / 0 / 1] |
5-009-205 | 33-40 | *CTL | [1 to 255 / 0 / 1] |
5-009-206 | 41-48 | *CTL | [1 to 255 / 0 / 1] |
5-009-207 | 49-56 | *CTL | [1 to 255 / 0 / 1] |
[mm/inch Display Selection]
Display units (mm or inch) for custom paper sizes. | |||
5-024-001 | 0:mm 1:inch | *CTL | [0 or 1 / 1(USA), 0(Others) / 1] 0: mm 1: inch |
5045 | [Accounting counter] | ||
5-045-001 | Counter Method | *CTL | [0 to 7 / 1 / step] 0: Developments 1: Prints 2: Coverage 7: Coverage (YMC) |
5047 | [Paper Display] | ||
5-047-001 | Backing Paper | *CTL | [0 or 1 / 0 / 1] 0: OFF 1: ON |
5051 | [TonerRefillDetectionDisplay] | ||
5-051-001 | - | *CTL | [0 or 1 / 0 / 1] 0: ON 1: OFF |
5055 | [Display IP Address] | ||
5-055-001 | - | *CTL | [0 or 1 / 0 / 1] 0: OFF 1: ON |
5061 | [Toner Remaining Icon Display Change] | ||
5-061-001 | - | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5062 | [Parts Replacement Alert Display] | ||
5-062-002 | #Photoconductor Unit (Black) | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-003 | #Development unit: Bk | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-025 | #Photoconductor Unit (Cyan) | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-026 | #Development unit: C | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-048 | #Photoconductor Unit (Magenta) | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-049 | #Development unit: M | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-071 | #Photoconductor Unit (Yellow) | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-072 | #Development unit: Y | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-093 | #Intermediate Transfer Unit | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-102 | #ITB Cleaning Unit | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
Controller SP Mode Tables
5-062-109 | #Paper Transfer Unit | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-115 | #Fuser Unit | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-116 | Fuser Unit: Belt | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-118 | Fuser Unit: Pressure Roller | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-131 | #Dust Filter | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-142 | #Wast Toner bottle | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-206 | #ADF Pick-up Roller | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-207 | #ADF Paper Supply Belt | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5-062-208 | #ADF Separate Roller | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5066 | [PM Parts Display] | ||
5-066-001 | - | *CTL | [0 or 1 / 0 / 1] 0: Not display 1: Display |
5067 | [Part Replacement Operation Type] | ||
5-067-002 | #Photoconductor Unit (Black) | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-003 | #Development unit: Bk | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-025 | #Photoconductor Unit (Cyan) | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-026 | #Development unit: C | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-048 | #Photoconductor Unit (Magenta) | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-049 | #Development unit: M | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-071 | #Photoconductor Unit (Yellow) | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-072 | #Development unit: Y | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-093 | #Intermediate Transfer Unit | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-102 | #ITB Cleaning Unit | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
Controller SP Mode Tables
5-067-109 | #Paper Transfer Unit | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-115 | #Fuser Unit | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-116 | Fuser Unit: Belt | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-118 | Fuser Unit: Pressure Roller | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-131 | #Dust Filter | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-142 | #Wast Toner bottle | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-206 | #ADF Pick-up Roller | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-207 | #ADF Paper Supply Belt | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5-067-208 | #ADF Separate Roller | *CTL | [0 or 1 / 0 / 1] 0: Service 1: User |
5071 | [Set Bypass Paper Size Display] | ||
5-071-001 | - | CTL | [0 or 1 / 0 / 1] 0: Off 1: On |
5073 | [Supply Part Replacement Opration Type] | ||
5-073-001 | Waste Tonner Bottle | *CTL | [0 or 1 / 0 / 1] 0:No Display 1:Display |
Controller SP Mode Tables
5074 | [Home Screen Login] | ||
5-074-002 | Login Setting | *CTL | [0 to 255 / 0 / 1] |
5-074-050 | Show Home Edit Menu | *CTL | [0 to 2 / 0 / 1] |
5-074-091 | Function Setting | *CTL | [0 to 2 / 0 / 1] 0: Function disable 1: SDK application 2: Legacy application (reserved) |
5-074-092 | Product ID | *CTL | [0x00 to 0xffff / - / 1] |
5-074-093 | Application Screen ID | *CTL | [0 to 255 / 0 / 1] |
5075 | [USB Keyboard] | ||
5-075-003 | Display setting | *CTL | [0 or 1 / 0 / 1] 0: Disable 1: Enable |
5081 | [ServiceSP Entery Code Setting] | ||
DFU | |||
5-081-001 | ServiceSP Entery Code Setting | - | - |
5083 | [LED Light Switch Setting] | ||
5-083-001 | Toner Near End | *CTL | [0 or 1 / 0 / 1] 0: OFF 1: ON |
5-083-002 | Waste Toner Near End | *CTL | [0 or 1 / 0 / 1] |
5102 | [AutoDetect] | ||
5-102-203 | HumanDetectSetting | *CTL | [0 or 1 / 0 / 1] |
5114 | [Optional Counter I/F] | ||
5-114-001 | MF Key Card Extension | *CTL | [0 or 1 / 0 / 1] 0: Not installed 1: Installed (scanning accounting) |
5118 | [Disable Copying] | ||
5-118-001 | - | *CTL | [0 or 1 / 0 / 1] 0: Not disabled 1: Disabled |
5120 | [Mode Clear Opt. Counter Removal] | ||
5-120-001 | 0:Yes 1:StandBy 2:No | *CTL | [0 to 2 / 0 / 1] 0: Yes (removed) 1: Standby (installed but not used) 2: No (not removed) |
5121 | [Counter Up Timing] | ||
5-121-001 | 0:Feed 1:Exit | *CTL | [0 or 1 / 0 / 1] 0: Feed 1: Exit |
5127 | [APS Mode] | ||
5-127-001 | - | *CTL | [0 or 1 / 0 / 1] 0: Not disabled 1: Disabled |
5148 | [Size Detection Off] | ||
5-148-002 | Tray 1 | *CTL | [0 or 1 / 0 / 1] |
5150 | [Length Setting] | ||
5-150-001 | Bypass(0:OFF 1:Long) | CTL | [0 or 1 / 0 / 1] 0: OFF 1: ON |
5193
Controller SP Mode Tables
5162 | [App. Switch Method] | ||
5-162-001 | - | *CTL | [0 or 1 / 0 / 1] 0: Soft Key Set 1: Hard Key Set |
5167 | [Fax Printing Mode at Optional Counter Off] | ||
5-167-001 | - | *CTL | [0 or 1 / 0 / 1] 0: Automatic printing 1: No automatic printing |
5169 | [CE Login] | ||
5-169-001 | *CTL | [0 or 1 / 0 / 1] 0: Disabled 1: Enabled |
5188 | [Copy Nv Version] | ||
5-188-001 | - | *CTL | [- / - / -] |
5191 | [Mode Set] | ||
5-191-001 | Power Str Set | *CTL | [0 or 1 / 1 / 1] 0: OFF 1: ON |
[External Controller Info. Settings]
5-193-001 | - | CTL | [0 to 10 / 0 / 1] 0: External Controller is not installed 1: EFI 2: Ratio 3: Egret 4: GJ 5:Creo 6: QX-100 7: Kurofune 8 to 10: Reserved |
5195 | [Limitless SW] | ||
5-195-001 | - | *CTL | [0 or 1 / 0 / 1] 0: Productivity Precede 1: Use paper up |
5196 | [Copier Vendor Mode] | ||
5-196-001 | 90 deg. Rotation | CTL | [0 or 1 / 0 / 1] |
5-196-002 | Color and Tray Selection | CTL | [0 or 1 / 0 / 1] |
5199 | [Paper Exit After Staple End] | ||
5-199-001 | Staple(1:Without 2:After 0:Auto) | CTL | [0 to 2 / 0 / 1] |
5-199-002 | Saddle(1:Without 2:After 0:Auto) | CTL | [0 to 2 / 0 / 1] |
5-199-003 | Stapless(1:Without 2:After 0:Auto) | CTL | [0 to 2 / 0 / 1] |
5212 | [Page Numbering] | ||
5-212-003 | Duplex Printout Left/Right Position of Left/Right Facing | *CTL | [-10 to 10 / 0 / 0.01mm/step] |
5-212-004 | Duplex Printout Top/Bottom Position of Left/Right Facing | *CTL | [-10 to 10 / 0 / 0.01mm/step] |
5-212-018 | Duplex Printout Left/Right Position of Top/Bottom Facing | *CTL | [-10 to 10 / 0 / 0.01mm/step] |
5-212-019 | Duplex Printout Top/Bottom Position of Top/Bottom Facing | *CTL | [-10 to 10 / 0 / 0.01mm/step] |
Controller SP Mode Tables
5227 | [Page numbering] | ||
5-227-201 | Allow Page No. Entry | *CTL | [2 to 9 / 9 / 1] |
5-227-202 | Zero Surplus Stting | *CTL | [0 or 1 / 0 / 1] 0:OFF 1:ON |
5302 | [Set Time] | ||
Adjusts the RTC (real time clock) time setting for the local time zone. Examples: For Japan (+9 GMT), enter 540 (9 hours x 60 min.) DOM: +540 (Tokyo) NA: -300 (New York) EU: + 60 (Paris) CH: +480 (Beijing) TW: +480 (Taipei) AS: +480 (Hong Kong) | |||
5-302-002 | Time Difference | *CTL | [-1440 to 1440 / - / 1min/step] |
5305 | [Auto Off Set] | ||
5-305-101 | Auto Off Limit Set | *CTL | [0 or 1 / 1 / 1] |
5307 | [Daylight Saving Time] |
5-307-001 | Setting | *CTL | [0 to 1 / - / 1] 0: Disabled 1: Enabled (Default) 1: NA and EUR 0: ASIA and others | |
Enables or disables the summer time mode.
| ||||
5-307-003 | Rule Set (Start) | *CTL | [0 to 0xffffffff / - / 1hex] (Default) NA: 0x11100200 EUR: 0x10500100 ASIA: 0x03100000 Other: 0x00000000 | |
Specifies the start setting for the summer time mode. There are 8 digits in this SP. For months 1 to 9, the "0" cannot be input in the first digit, so the eight-digit setting for -2 or -3 becomes a seven-digit setting. 1st and 2nd digits: The month. [1 to 12] 3rd digit: The week of the month. [1 to 5] 4th digit: The day of the week. [0 to 6 = Sunday to Saturday] 5th and 6th digits: The hour. [00 to 23] 7th digit: The length of the advanced time. [0 to 9 / 1 hour ] 8th digit: The length of the advanced time. [0 to 5 / 10 minutes ]
| ||||
5-307-004 | Rule Set (End) | *CTL | [0 to 0xffffffff / - / 1hex] |
Controller SP Mode Tables
Specifies the end setting for the summer time mode. There are 8 digits in this SP.
1st and 2nd digits: The month. [1 to 12] 3rd digit: The week of the month. [0 to 5]
4th digit: The day of the week. [0 to 7 = Sunday to Saturday] 5th and 6th digits: The hour. [00 to 23]
The 7th and 8 digits must be set to "00".
The digits are counted from the left.
Make sure that SP5-307-1 is set to "1".
5401 | [Access Control] | ||
5-401-103 | Default Document ACL | CTL | [0 to 3 / 0 / 1] |
5-401-104 | Authentication Time | CTL | [0 to 255 / 0 / 1sec/step] |
5-401-162 | Extend Certification Detail | CTL | [0 to 0xff / 0 / 1] |
5-401-200 | SDK1 UniqueID | CTL | [0 to 0xFFFFFFFF / 0 / 1] |
5-401-201 | SDK1 Certification Method | CTL | [0 to 0xFF / 0 / 1] |
5-401-210 | SDK2 UniqueID | CTL | [0 to 0xFFFFFFFF / 0 / 1] |
5-401-211 | SDK2 Certification Method | CTL | [0 to 0xFF / 0 / 1] |
5-401-220 | SDK3 UniqueID | CTL | [0 to 0xFFFFFFFF / 0 / 1] |
5-401-221 | SDK3 Certification Method | CTL | [0 to 0xFF / 0 / 1] |
5-401-230 | SDK Certification Device | *CTL | [0 to 7 / 0 / power of 2] 0-1: SDK authentication available 0-0: Disable all functions 1-1: SKB Display 1-0: Disable 2-1: Administrator login 2-0: Disable 3 to 7-0: Reserved (set “0” only) |
5-401-240 | Detail Option | *CTL | [0 to 7 / 0x00 / 0x01] |
0: Logout confirm option
-1: ON, 0: OFF
2 to 1: Auto-logout timer(retry timer)
-11: 30sec, 10: 20sec, 01: 10sec, 00: 60sec
3: personal authority / Group authority and operation
-1: ON, 0: OFF
4: Skip password entry
-1: ON, 0: OFF
5: Set the display of the remaining Frequence
-1: ON, 0: OFF
6 to 7: Set the display time
-1: ON, 0: OFF
5402 | [Access Control] | ||
5-402-101 | SDKJ1 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-102 | SDKJ2 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-103 | SDKJ3 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-104 | SDKJ4 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-105 | SDKJ5 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-106 | SDKJ6 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-107 | SDKJ7 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-108 | SDKJ8 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-109 | SDKJ9 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-110 | SDKJ10 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-111 | SDKJ11 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-112 | SDKJ12 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-113 | SDKJ13 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-114 | SDKJ14 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-115 | SDKJ15 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-116 | SDKJ16 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-117 | SDKJ17 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-118 | SDKJ18 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-119 | SDKJ19 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-120 | SDKJ20 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-121 | SDKJ21 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-122 | SDKJ22 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-123 | SDKJ23 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-124 | SDKJ24 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-125 | SDKJ25 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-126 | SDKJ26 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-127 | SDKJ27 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-128 | SDKJ28 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-129 | SDKJ29 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-130 | SDKJ30 Limit Setting | CTL | [0 to 0xff / 0 / 1] |
5-402-141 | SDKJ1 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-142 | SDKJ2 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-143 | SDKJ3 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-144 | SDKJ4 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-145 | SDKJ5 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-146 | SDKJ6 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-147 | SDKJ7 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-148 | SDKJ8 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-149 | SDKJ9 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-150 | SDKJ10 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-151 | SDKJ11 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-152 | SDKJ12 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
Controller SP Mode Tables
5-402-153 | SDKJ13 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-154 | SDKJ14 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-155 | SDKJ15 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-156 | SDKJ16 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-157 | SDKJ17 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-158 | SDKJ18 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-159 | SDKJ19 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-160 | SDKJ20 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-161 | SDKJ21 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-162 | SDKJ22 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-163 | SDKJ23 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-164 | SDKJ24 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-165 | SDKJ25 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-166 | SDKJ26 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-167 | SDKJ27 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-168 | SDKJ28 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-169 | SDKJ29 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5-402-170 | SDKJ30 ProductID | CTL | [0 to 0xffffffff / 0 / 1] |
5411
5404 | [User Code Count Clear] | ||
5-404-001 | User Code Count Clear | *CTL | [- / - / -] [Execute] |
5-404-101 | User Code Count Clear Permit Setting | *CTL | [0 or 1 / 0 / 1] |
[LDAP-Certification]
5-411-004 | Easy Certification | *CTL | [0 or 1 / 1 / 1] 1: On 0: Off |
5-411-005 | Password Null Not Permit | *CTL | [0 or 1 / 0 / 1] 0: Password NULL not permitted. 1: Password NULL permitted. |
5-411-006 | Detail Option | *CTL | [0 or 1 / 0 / 1] 0: OFF 1: ON |
Controller SP Mode Tables
5412 | [Krb-Certification] | ||
5-412-100 | Encrypt Mode | CTL | [0 to 0xFF / 0x1F / 1] |
5413 | [Lockout Setting] | ||
5-413-001 | Lockout On/Off | *CTL | [0 or 1 / 0 / 1] 0: Off 1: On |
5-413-002 | Lockout Threshold | *CTL | [1 to 10 / 5 / 1] |
5-413-003 | Cancellation On/Off | *CTL | [0 or 1 / 0 / 1] 0: Off (no wait time, lockout not cancelled) 1: On (system waits, cancels lockout if correct user ID and password are entered. |
5-413-004 | Cancellation Time | *CTL | [1 to 9999 / 60 / 1min] |
5414 | [Access Mitigation] | ||
5-414-001 | Mitigation On/Off | *CTL | [0 or 1 / 0 / 1] 0: OFF 1: ON |
5-414-002 | Mitigation Time | *CTL | [0 to 60 / 15 / 1min/step] |
5415 | [Password Attack] | ||
5-415-001 | Permissible Number | *CTL | [0 to 100 / 30 /1attempt/step] |
5-415-002 | Detect Time | *CTL | [1 to 10 / 5 / 1sec/step] |
5416 | [Access Information] | ||
5-416-001 | Access User Max Num | *CTL | [50 to 200 / 200 / 1user/step] |
5-416-002 | Access Password Max Num | *CTL | [50 to 200 / 200 / 1password/step] |
5-416-003 | Monitor Interval | *CTL | [1 to 10 / 3 / 1sec/step] |
5417 | [Access Attack] | ||
5-417-001 | Access Permissible Number | *CTL | [0 to 500 / 100 / 1/step] |
5-417-002 | Attack Detect Time | *CTL | [10 to 30 / 10 / 1sec/step] |
5-417-003 | Productivity Fall Wait | *CTL | [0 to 9 / 3 / 1sec/step] |
5-417-004 | Attack Max Num | *CTL | [50 to 200 / 200 / 1attempt/step] |
5420 | [User Authentication] | ||
5-420-001 | Copy | *CTL | [0 to 1 / 0 / 1] 0: On 1: Off |
5-420-002 | Color Security Setting | *CTL | [0x00 to 0xFF / 0x00 / 1] |
5-420-011 | DocumentServer | *CTL | [0 or 1/ 0 / 1] 0: On 1: Off |
5-420-021 | Fax | *CTL | [0 or 1/ 0 / 1] 0: On 1: Off |
5-420-031 | Scanner | *CTL | [0 or 1/ 0 / 1] 0: On 1: Off |
5-420-041 | Printer | *CTL | [0 or 1/ 0 / 1] 0: On 1: Off |
5-420-051 | SDK1 | *CTL | [0 or 1 / 0 / 1] 0: ON 1: OFF |
5-420-061 | SDK2 | *CTL | |
5-420-071 | SDK3 | *CTL | |
5-420-081 | Browser | *CTL | [0 or 1 / 0 / 1] 0: ON 1: OFF |
Controller SP Mode Tables
5430 | [Auth Dialog Message Change] | ||
5-430-001 | Message Change On/Off | CTL | [0 or 1 / 0 / 1] |
5-430-002 | Message Text Download | CTL | [- / - / -] |
5-430-003 | Message Text ID | CTL | [- / - / -] |
5431 | [External Auth User Preset] | ||
5-431-010 | Tag | CTL | [0 or 1 / 1 / 1] |
5-431-011 | Entry | CTL | [0 or 1 / 1 / 1] |
5-431-012 | Group | CTL | [0 or 1 / 1 / 1] |
5-431-020 | CTL | [0 or 1 / 1 / 1] | |
5-431-030 | Fax | CTL | [0 or 1 / 1 / 1] |
5-431-031 | FaxSub | CTL | [0 or 1 / 1 / 1] |
5-431-032 | Folder | CTL | [0 or 1 / 1 / 1] |
5-431-033 | ProtectCode | CTL | [0 or 1 / 1 / 1] |
5-431-034 | SmtpAuth | CTL | [0 or 1 / 1 / 1] |
5-431-035 | LdapAuth | CTL | [0 or 1 / 1 / 1] |
5-431-036 | Smb Ftp Fldr Auth | CTL | [0 or 1 / 1 / 1] |
5-431-037 | AcntAcl | CTL | [0 or 1 / 1 / 1] |
5-431-038 | DocumentAcl | CTL | [0 or 1 / 1 / 1] |
5-431-040 | CertCrypt | CTL | [0 or 1 / 0 / 1] |
5-431-050 | UserLimitCount | CTL | [0 or 1 / 1 / 1] |
5504
5481 | [Authentication Error Code] | ||
5-481-001 | System Log Disp | *CTL | [0 or 1 / 0 / 1] 0: Off 1: On |
5-481-002 | Panel Disp | *CTL | [0 or 1 / 0 / 1] 1: On 0: Off |
5490 | [MF KeyCard (Japan only)] | ||
5-490-001 | Job Permit Setting | *CTL | [0 to 1 / 0 / 1] 0: Disabled. Cancels operation without a user code. 1: Enabled. Allows operation without a user code. |
5-490-002 | Count Mode Setting | *CTL | - |
5491 | [Optional Counter] | ||
5-491-001 | Detail Option | *CTL | [0 to 0xff / 0 / 1] |
5501 | [PM Alarm] | ||
5-501-001 | PM Alarm Level | *CTL | [0 to 9999 / 0 / 1] 0: Alarm off 1 to 9999: Alarm goes off when Value (1 to 9999) x 1000 > PM counter |
[Jam Alarm]
5-504-001 | - | *CTL | [0 to 3 / 3 / 1] 0: Z 1: L 2: M 3: H |
5-504-002 | Threshold | *CTL | [1 to 99 / 10 / 1] |
Controller SP Mode Tables
5505 | [Error Alarm] | ||
5-505-001 | Error Alarm | *CTL | [0 to 255 / * / 1 x102 sheets/step] 0: Alarm Off * C2503 :20 / C2003:15 |
5-505-002 | Threshold | *CTL | [1 to 99 / 5 / 1] |
5507 | [Supply/CC Alarm] | ||
5-507-001 | Paper Supply Alarm | *CTL | [0 or 1 / 0 / 1] 0: OFF 1: ON |
5-507-002 | Staple Supply Alarm | *CTL | [0 or 1 / 0 / 1] 0: OFF 1: ON |
5-507-003 | Toner Supply Alarm | *CTL | [0 or 1 / 0 / 1] 0: OFF 1: ON |
5-507-006 | WasteTonerBottle | *CTL | [0 to 2 / 1 / 1] 0:OFF 1: Supply Call ON 2: CC Call ON |
5-507-080 | Toner Call Timing | *CTL | [0 or 1 / 0 / 1] 0: Toner bottle replacement 1: Less than toner threshold |
5-507-080 | Toner Call Timing | CTL | [0 or 1 / 0 / 1] |
5-507-081 | Toner Call Threshold:Bk | CTL | [10 to 90 / 10 / 10%/step] |
5-507-082 | Toner Call Threshold:CMY | CTL | [10 to 90 / 10 / 10%/step] |
5-507-128 | Interval :Others | *CTL | [250 to 10000 / 1000 / 1page/step] |
5-507-132 | Interval :A3 | *CTL | [250 to 10000 / 1000 / 1page/step] |
5-507-133 | Interval :A4 | *CTL | [250 to 10000 / 1000 / 1page/step] |
5-507-134 | Interval :A5 | *CTL | [250 to 10000 / 1000 / 1page/step] |
5-507-141 | Interval :B4 | *CTL | [250 to 10000 / 1000 / 1page/step] |
5-507-142 | Interval :B5 | *CTL | [250 to 10000 / 1000 / 1page/step] |
5-507-160 | Interval :DLT | *CTL | [250 to 10000 / 1000 / 1page/step] |
5-507-164 | Interval: LG | *CTL | [250 to 10000 / 1000 / 1page/step] |
5-507-166 | Interval :LT | *CTL | [250 to 10000 / 1000 / 1page/step] |
5-507-172 | Interval :HLT | *CTL | [250 to 10000 / 1000 / 1page/step] |
5508 | [CC Call] | ||
5-508-001 | Jam Remains | *CTL | [0 or 1 / 1 / 1] 0: Disable 1: Enable |
5-508-002 | Continuous Jams | *CTL | [0 or 1 / 1 / 1] 0: Disable 1: Enable |
5-508-003 | Continuous Door Open | *CTL | [0 or 1 / 1 / 1] 0: Disable 1: Enable |
5-508-011 | Jam Detection: Time Length | *CTL | [3 to 30 / 10 / 1min/step] |
5-508-012 | Jam Detection: Continuous Count | *CTL | [2 to 10 / 5 / 1time/step] |
5-508-013 | Door Open: Time Length | *CTL | [3 to 30 / 10 / 1min/step] |
Controller SP Mode Tables
5513 | [PartsAlermlevelCount] | ||
5-513-001 | Normal | *CTL | [1 to 9999 / 300 / 1] |
5-513-002 | Df | *CTL | [1 to 9999 / 300 / 1] |
5514 | [PartsAlermlev] | ||
5-514-001 | Normal | *CTL | [0 or 1 / 1 / 1] |
5-514-002 | Df | *CTL | [0 or 1 / 0 / 1] |
5515 | [SC/Alarm Setting] | ||
5-515-001 | SC Call | *CTL | [0 or 1 / 1 / 1] 0: OFF 1: ON |
5-515-002 | Service Parts Near End Call | *CTL | |
5-515-003 | Service Parts End Call | *CTL | |
5-515-004 | User Call | *CTL | |
5-515-006 | Communication Test Call | *CTL | |
5-515-007 | Machine Information Notice | *CTL | |
5-515-008 | Alarm Notice | *CTL | |
5-515-009 | Non Genuine Tonner Ararm | *CTL |
5-515-010 | Supply Automatic Ordering Call | *CTL | |
5-515-011 | Supply Management Report Call | *CTL | |
5-515-012 | Jam/Door Open Call | *CTL | |
5-515-050 | Timeout:Manual Call | *CTL | [1 to 255 / 5 / 1min/step] |
5-515-051 | Timeout:Other Call | *CTL | [1 to 255 / 10 / 1min/step] |
5517 | [Get Machine Information] | ||
5-517-031 | Get SMC Info: Retry Interval | *CTL | [10 to 255 / 10 / 1min/step] |
5618 | [Color Mode Display Selection] | ||
5-618-001 | - | *CTL | [0 or 1 / 1 / 1] 0: ACS, Color, Black & White, Two Colors, Single color 1: ACD, Full Color, Black & White |
5728 | [Network Setting] | ||
5-728-001 | NAT Machine Port1 | CTL | [1 to 65535 / 49101 / 1] |
5-728-002 | NAT UI Port1 | CTL | [1 to 65535 / 55101 / 1] |
5-728-003 | NAT Machine Port2 | CTL | [1 to 65535 / 49102 / 1] |
5-728-004 | NAT UI Port2 | CTL | [1 to 65535 / 55102 / 1] |
5-728-005 | NAT Machine Port3 | CTL | [1 to 65535 / 49103 / 1] |
5-728-006 | NAT UI Port3 | CTL | [1 to 65535 / 55103 / 1] |
5-728-007 | NAT Machine Port4 | CTL | [1 to 65535 / 49104 / 1] |
5-728-008 | NAT UI Port4 | CTL | [1 to 65535 / 55104 / 1] |
5-728-009 | NAT Machine Port5 | CTL | [1 to 65535 / 49105 / 1] |
5-728-010 | NAT UI Port5 | CTL | [1 to 65535 / 55105 / 1] |
5-728-011 | NAT Machine Port6 | CTL | [1 to 65535 / 49106 / 1] |
5-728-012 | NAT UI Port6 | CTL | [1 to 65535 / 55106 / 1] |
5-728-013 | NAT Machine Port7 | CTL | [1 to 65535 / 49107 / 1] |
5-728-014 | NAT UI Port7 | CTL | [1 to 65535 / 55107 / 1] |
5-728-015 | NAT Machine Port8 | CTL | [1 to 65535 / 49108 / 1] |
5-728-016 | NAT UI Port8 | CTL | [1 to 65535 / 55108 / 1] |
5-728-017 | NAT Machine Port9 | CTL | [1 to 65535 / 49109 / 1] |
5-728-018 | NAT UI Port9 | CTL | [1 to 65535 / 55109 / 1] |
5-728-019 | NAT Machine Port10 | CTL | [1 to 65535 / 49110 / 1] |
5-728-020 | NAT UI Port10 | CTL | [1 to 65535 / 55110 / 1] |
5741
Controller SP Mode Tables
5730 | [Extended Function Setting] | ||
5-730-001 | JavaTM Platform setting | *CTL | [0 or 1 / 1 / -] 0: Disable, 1: Enable |
5-730-010 | Expiration Prior Alarm Set | *CTL | [0 to 999 / 20 / 1day/step] |
5731 | [Counter Effect] | ||
This SP is used only for DOM machines. | |||
5-731-001 | Change MK1 Cnt (Paper->Combine) | *CTL | [0 or 1 / 0 / 1] |
5732 | [Reset Job After Jam(Copy)] | ||
5-732-002 | *CTL | [0 or 1 / 0 / 1] |
5734 | [PDF Setting] | ||
5-734-001 | PDF/A Fixed | *CTL | [0 or 1 / 0 / 1] |
[Node Authentication Timuout]
5-741-001 | *CTL | [1 to 255 / 60 / 1sec/step] |
5745 | [DeemedPowerConsumption] | ||
5-745-211 | Controller Standby | *CTL | [0 to 9999 / 0 / 1] |
5-745-212 | STR | *CTL | [0 to 9999 / 0 / 1] |
5-745-213 | Main Power Off | *CTL | [0 to 9999 / 0 / 1] |
5-745-214 | Scanning and Printing | *CTL | [0 to 9999 / 0 / 1] |
5-745-215 | Printing | *CTL | [0 to 9999 / 0 / 1] |
5-745-216 | Scanning | *CTL | [0 to 9999 / 0 / 1] |
5-745-217 | Engine Standby | *CTL | [0 to 9999 / 0 / 1] |
5-745-218 | Low Power Consumption | *CTL | [0 to 9999 / 0 / 1] |
5-745-219 | Silent condition | *CTL | [0 to 9999 / 0 / 1] |
5-745-220 | Heater Off | *CTL | [0 to 9999 / 0 / 1] |
5748 | [OpePanel Setting] | ||
5-748-101 | Op Type Action Setting | CTL | [0x00 to 0xFF / 0 / 0x01]
0: Normal operation panel 1: Smart operation panel |
5-748-201 | Cheetah Panel Connect Setting | CTL | [0 or 1 / 0 / 0] 0: OFF 1: ON |
5749 | [Import/Export] | ||
5-749-001 | Export | CTL | [- / - / -] Target: System, Printer, Fax, Scanner Option: Unique, Secret Copy config: Encryption, Encryption key(if selected) [Execute] |
5-749-101 | Import | CTL | [- / - / -] Option: Unique Copy config: Encryption, Encryption key(if selected) [Execute] |
Controller SP Mode Tables
5751 | [Key Event Encryption Setting] | ||
5-751-001 | Password | CTL | [0 to 255 / 0 / 1] |
5752 | [Copy:WebAPI Setting] | |||
5-752-001 | Copy FlairAPI Setting | *CTL | * see BitSwitch below: | |
Bit | Setting | meanings | Description | |
0 | 1 | |||
bit 0 | Start of FlairAPI Server | Off (Do not Start) | On (Start) | Sets whether to start exclusive FlairAPI http server. If it is 0, scanning FlairAPI function and simple UI function will be disabled. The machine installed Android operating panel option, set “1”, others set “0”. |
bit 1 | Access permission of FlairAPI from outside of the machine | Disabled | Enabled | If it is “0”, accessing is limited from the machine only, such as operating panel, SDK/J, MFP browsers etc... If it is “1”, accessing is allowed from outside of FlairAPI such as PC, Remote UI, IT-Box etc... |
bit 2 | Reserved | - | - | - |
bit 3 | Reserved | - | - | - |
bit 4 | Simple UI Function | Disabled | Enabled | If it is “1”, the machine can be used Scanner Simple UI. If it is “0”, requesting URL of Simple UI returns “404 Not Found” |
bit 5 | Accessing permission of Simple UI from outside of the machine | Disabled | Enabled | If it is “0”, accessing is limited from the machine only (operating panel and MFP browser). If it is “1”, accessing is allowed from outside of Simple UI such as PC, mobile devices, and so on. |
bit 6 | Reserved | - | - | - |
bit 7 | Reserved | - | - | - |
5801
5755 | [Display Setting] | ||
5-755-001 | Disp Administrator Password Change Scrn | CTL | [- / - / -] |
5-755-002 | Hide Administrator Password Change Scrn | CTL | [- / - / -] |
5758 | [RemoteUI Setting] | ||
5-758-001 | Authentication | *CTL | [0 or 1 / 0 / 1] |
5759 | [Machine Limit Count] | ||
5-759-001 | Machine Limit Count Setting | *CTL | [0 or 1 / 0 / 1] |
5-759-061 | Full Color Limit Count | *CTL | [0 to 99999999 / 0 / 1] |
5-759-062 | Mono Color Limit Count | *CTL | [0 to 99999999 / 0 / 1] |
[Memory Clear]
5-801-001 | All Clear | CTL | [- / - / -] [Execute] |
5-801-003 | SCS | CTL | [- / - / -] [Execute] |
5-801-004 | IMH Memory Clr | CTL | [- / - / -] [Execute] |
5-801-005 | Mcs | CTL | [- / - / -] [Execute] |
5-801-006 | Copier Application | CTL | [- / - / -] [Execute] |
5-801-007 | Fax Application | CTL | [- / - / -] [Execute] |
5-801-008 | Printer Application | CTL | [- / - / -] [Execute] |
The following service settings:
The following user settings: | |||
5-801-009 | Scanner Application | CTL | [- / - / -] [Execute] |
5-801-010 | Web Service | CTL | [- / - / -] [Execute] |
5-801-011 | NCS | CTL | [- / - / -] [Execute] |
5-801-012 | R-Fax | CTL | [- / - / -] [Execute] |
Controller SP Mode Tables
5-801-014 | Clear DCS Setting | CTL | [- / - / -] [Execute] |
5-801-015 | Clear UCS Setting | CTL | [- / - / -] [Execute] |
5-801-016 | MIRS Memory Clr | CTL | [- / - / -] [Execute] |
5-801-017 | CCS | CTL | [- / - / -] [Execute] |
5-801-018 | SRM Memory Clr | CTL | [- / - / -] [Execute] |
5-801-019 | LCS Memory Clr | CTL | [- / - / -] [Execute] |
5-801-020 | Web Uapli | CTL | [- / - / -] [Execute] |
5-801-021 | ECS | CTL | [- / - / -] [Execute] |
5-801-023 | AICS | CTL | [- / - / -] [Execute] |
5-801-025 | Websys | CTL | [- / - / -] [Execute] |
5-801-026 | PLN | CTL | [- / - / -] [Execute] |
5-801-027 | SAS | CTL | [- / - / -] [Execute] |
5-801-028 | Rest WebService | CTL | [- / - / -] [Execute] |
5816 | [Remote Service] | |||
5-816-001 | I/F Setting | *CTL | [0 to 2 / 2 / 1] 0: Remote service off 1: CSS remote service on 2: NRS remote service on | |
5-816-002 | CE Call | *CTL | [0 or 1 / 0 / 1] 0: Start of the service 1: End of the service | |
5-816-003 | Function Flag | *CTL | [0 or 1 / 0 / 1] 0: Disabled 1: Enabled | |
5-816-007 | SSL Disable | *CTL | [0 or 1 / 0 / 1] 0: Yes. SSL not used. 1: No. SSL used. | |
5-816-008 | RCG Connect Timeout | *CTL | [1 to 90 / 30 / 1second/step] | |
5-816-009 | RCG Write Timeout | *CTL | [0 to 100 / 60 / 1second/step] | |
5-816-010 | RCG Read Timeout | *CTL | [0 to 100 / 60 / 1second/step] | |
5-816-011 | Port 80 Enable | *CTL | [0 or 1 / 0 / 1] 0: No. Access denied 1: Yes. Access granted. | |
5-816-013 | RFU Timing | *CTL | [0 or 1 / 1 / 1] 0: Any status of a target machine 1: Sleep or panel off mode only | |
5-816-014 | RCG Error Cause | CTL | [0 or 1 / 0 / 1] 0: Initial state, normal condition 1: Error | |
5-816-021 | RCG – C Registed | *CTL | [0 or 1 / 0 / 1] 0: Installation not completed 1: Installation completed |
5-812-003 | Supply | *CTL | [up to 20 / - / 1] |
5-812-004 | Operation | *CTL | [up to 20 / - / 1] |
Controller SP Mode Tables
5812 | [Service Tel. No. Setting] | ||
5-812-001 | Service | *CTL | [up to 20 / - / 1] |
5-812-002 | Facsimile | *CTL | [up to 20 / - / 1] |
5-816-023 | connect type(N/M) | *CTL | [0 or 1 / 0 / 1] 0: internet connection 1: Dial-up connection | |
5-816-061 | Cert Expire Timing | *CTL | [0 to 0xffffffff / 0 / 1] 0: Not use 1: Use | |
5-816-062 | Use Proxy | *CTL | [0 or 1 / 0 / 1] 0: Not use 1: Use | |
5-816-063 | Proxy Host | *CTL | [- / - / -] | |
5-816-064 | Proxy PortNumber | *CTL | [0 to 0xffff / 0 / 1] | |
5-816-065 | Proxy User Name | *CTL | [up to 31 / - / 1] | |
5-816-066 | Proxy Password | *CTL | [up to 31 / - / 1] | |
5-816-067 | Proxy Password | *CTL | [0 to 255 / 0 / 1] | |
Displays status of the certification used for Cumin. If it is not installed as Cumin, the value of this SP will be set when it installed, after checking the certification status. | ||||
0 | The certification adequately set on the machine. | |||
1 | Request for certification update in progress. | |||
2 | Certification Update completed and notification of the success status to the G/W in progress. | |||
3 | Certification Update failed and notification of the result to the G/W in progress. | |||
4 | Certification expiration date will be coming soon. Notifying the G/W to request for certification update. | |||
11 | Rescue certification setting for connecting to the rescue G/W in progress because update for rescue certification needed. | |||
12 | Setting for rescue certification has completed. Requesting to the rescue G/W for updating certification. |
13 | Notification for certification updating request has completed. Waiting for the certification update request from the rescue G/W. | |||
14 | Received the notification for certification updating request from the rescue G/W. Writing the certification. | |||
15 | Writing the certification has completed. Notifying the result of certification update to the G/W. | |||
16 | Writing the certification has failed. Notifying the result of certification update to the G/W. | |||
17 | Writing a rescue certification because received a certification error again after completed the certification update request from the G/W and noticed the result of certification update with the updated certification. | |||
18 | The writing operation mentioned in #17 has completed. Notifying the result of certification update to the rescue G/W. | |||
5-816-068 | CERT: Error | *CTL | [0 to 255 / 0 / 1] | |
Displays a number code that describes the reason for the request for update of the certification. | ||||
0 | Normal. There is no request for certification update in progress. | |||
1 | Request for certification update in progress. The current certification has expired. | |||
2 | An SSL error notification has been issued. Issued after the certification has expired. | |||
3 | Notification of shift from a common authentication to an individual certification. | |||
4 | Notification of a common certification without ID2. | |||
5 | Notification that no certification was issued. | |||
6 | Notification that GW URL does not exist. | |||
5-816-069 | CERT: Up ID | *CTL | [- / - / -] | |
- |
Controller SP Mode Tables
5-816-083 | Firm Up Status | *CTL | [0 to 5 / 0 / 1] 0: Waiting for accepting firm update 1: Waiting for firm update start schedule 2: Waiting for user confirmation 3: In preparation for the machine firm update 4: processing the machine firm update 5: processing the closing operation of the machine firm update | |
5-816-085 | Firm Up User Check | CTL | [- / - / -] | |
5-816-086 | Firmware Size | CTL | [- / - / -] | |
5-816-087 | CERT:Macro Ver. | CTL | [8digits / - / 1digit/step] | |
5-816-088 | CERT:PAC Ver. | CTL | [16digits / - / 1digit/step] | |
5-816-089 | CERT:ID2Code | CTL | [17digits / - / 1digit/step] | |
5-816-090 | CERT:Subject | CTL | [17digits / - / 1digit/step] | |
5-816-091 | CERT:Serial No. | CTL | [16digits / - / 1digit/step] | |
5-816-092 | CERT:Issuer | CTL | [30digits / - / 1digit/step] | |
5-816-093 | CERT:Valid Start | CTL | [10digits / - / 1digit/step] | |
5-816-094 | CERT:Valid End | CTL | [10digits / - / 1digit/step] | |
5-816-102 | CERT:Encrypt Level | *CTL | [1 to 2 / 1 / 1] | |
5-816-103 | Client Communication Method | CTL | [0 to 3 / 0 / 1] | |
5-816-104 | Client Communication Limit | CTL | [1 to 7 / 7 / 1] | |
5-816-115 | Network Information Waiting timer | CTL | [5 to 255 / 5 / 1sec/step] |
5-816-150 | Selection Country | CTL | [0 to 10 / 1 / 1] 0: Japan 1: USA 2: Canada 3: UK 4: Germany 5: France 6: Italy 7: Netherlands 8: Belgium 9: Luxembourg 10: Spain | |
Select the country where embedded RCG-M is installed in the machine. After selecting the country, you must also set the following SP codes for embedded RCG-M:
| ||||
5-816-151 | Line Type AutomaticJudgment | CTL | [- / - / -] [Execute] | |
5-816-152 | Line Type Judgment Result | CTL | [0 to 9 / - / 1] | |
Displays a number to show the result of the execution of SP5816 151. Here is a list of what the numbers mean. 0: Success 1: In progress (no result yet). Please wait. 2: Line abnormal 3: Cannot detect dial tone automatically 4: Line is disconnected 5: Insufficient electrical power supply 6: Line classification not supported 7: Error because fax transmission in progress – ioctl() occurred. 8: Other error occurred 9: Line classification still in progress. Please wait. |