5804

[OUTPUT Check]

5-804-202

Scanner Lamp

ENG

[0 or 1 / 0 / 1/step]

Checks output of scanner lamp.

Use to check light source malfunction when SC101-01, SC101-02, SC102-00, SC142-00 occurs.

5-804-206

PTR Open/Close LED

ENG

[0 or 1 / 0 / 1/step]

Lights paper transfer open/close LED.

5-804-208

TM/P Sensor: F

ENG

[0 or 1 / 0 / 1/step]

Lights TM/P sensor: Front glowing part.

5-804-209

TM/P Sensor: C

ENG

[0 or 1 / 0 / 1/step]

Lights TM/P sensor: Center glowing part.

5-804-210

TM/P Sensor: R

ENG

[0 or 1 / 0 / 1/step]

Lights TM/P sensor: Rear glowing part.

5-804-211

Toner Sensor Power

ENG

[0 or 1 / 0 / 1/step]

5-804-232

Toner IDTAG Power

ENG

[0 or 1 / 0 / 1/step]

5804

[OUTPUT Check]

5-804-239

Fusing Exit Drive Solenoid

ENG

[0 or 1 / 0 / 1/step]

5804

[OUTPUT Check]

Continuously drives specified motor for operation test.

5-804-241

Bank: Tray3: Feed Mt: Standard Speed

ENG

[0 or 1 / 0 / 1/step]

5-804-242

Bank: Tray4: Feed Mt: Standard Speed

ENG

5-804-243

Bank: Tray5: Feed Mt: Standard Speed

ENG

5-804-244

Bank: Tray3: Transport Mt: Standard Speed

ENG

5-804-245

Bank: Tray4: Transport Mt: Standard Speed

ENG


5-804-246

Bank: Tray5: Transport Mt: Standard Speed

ENG

5804

[OUTPUT Check]

Drives specified motor for a certain period of time to test operation.

5-804-247

Bank: Tray3: PU Solenoid

ENG

[0 or 1 / 0 / 1/step]

5-804-248

Bank: Tray4: PU Solenoid

ENG

5-804-249

Bank: Tray5: PU Solenoid

ENG


Engine SP Mode Tables

ADF


6008

[ADF OUTPUT Check]

Checks operation of the load of ADF.

6-008-003

Feed Motor Forward

ENG

[0 or 1 / 0 / 1/step]

Rotates paper feed motor forward.

6-008-004

Feed Motor Reverse

ENG

[0 or 1 / 0 / 1/step]

Rotates paper feed motor backward.

6-008-005

Relay Motor Forward

ENG

[0 or 1 / 0 / 1/step]

Rotates carry motor forward.

6-008-006

Relay Motor Reverse

ENG

[0 or 1 / 0 / 1/step]

Rotates carry motor backward.

6-008-011

Inverter Solenoid

ENG

[0 or 1 / 0 / 1/step]

Interval drives reverse solenoid.

6-008-012

Stamp

ENG

[0 or 1 / 0 / 1/step]

Interval drives DONE stamp.

6-008-013

Fan Motor

ENG

[0 or 1 / 0 / 1/step]


Interval drives FAN motor.

6-008-014

Feed Clutch

ENG

[0 or 1 / 0 / 1/step]

Interval drives paper feed clutch.

6-008-015

Feed Solenoid

ENG

[0 or 1 / 0 / 1/step]

Interval drives paper feed solenoid.



6012

[1-Pass ADF OUTPUT Check]

For Single-Pass simultaneous duplex models only.

6-012-001

Pick-Up Motor Forward

ENG

[0 or 1 / 0 / 1/step] 0:Off

1:On

Forwardly rotates ADF pick up motor.

6-012-003

Feed Motor Forward

ENG

[0 or 1 / 0 / 1/step] 0:Off

1:On

Forwardly rotates ADF paper feed motor.

6-012-005

Relay Motor Forward

ENG

[0 or 1 / 0 / 1/step] 0:Off

1:On

Forwardly rotates ADF paper carry motor.

6-012-009

Exit Motor Forward

ENG

[0 or 1 / 0 / 1/step] 0:Off

1:On

Forwardly rotates ADF paper exit motor.

6-012-010

Bottom Plate Motor For/Rev

ENG

[0 or 1 / 0 / 1/step] 0:Off

1:On

Moves up/down the bottom plate by driving the ADF bottom plate motor forward, backward.

6-012-012

Stamp

ENG

[0 or 1 / 0 / 1/step] 0:Off

1:On

Stamps the DONE stamp.

6-012-015

Pull-Out Motor Forward

ENG

[0 or 1 / 0 / 1/step] 0:Off

1:On

Forwardly rotates ADF pull out motor.

6-012-016

Middle Motor Forward

ENG

[0 or 1 / 0 / 1/step] 0:Off

1:On

Forwardly rotates ADF middle motor.


Engine SP Mode Tables

Finisher


6124

[OUTPUT Check: 2K/3K FIN]

6-124-001

Entrance Transport Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-002

Horizontal Transport Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-003

Pre-Stack Transport Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-004

ITB Transport Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-005

Paper Exit Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-006

Upper Junction Solenoid

ENG

[0 or 1 / 0 / 1/step]

Turns NO/OFF specified solenoid for validation.

6-124-007

TE Stack Plate Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-008

Paper Exit Open/Close Guide Plate Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-009

Punching Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-010

Punch Move Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-011

S-to-S Registration Detection Move Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-012

Lower Junction Solenoid Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-013

Jogger Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-014

Positioning Roller Rotation Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-015

Feed-out Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-016

Booklet Stapler Move Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-017

Corner Stapler Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-018

Booklet Stapler Jogger Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-019

Booklet Stapler Jog Solenoid Move Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-020

Booklet Stapler Standard Fence Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-021

Booklet Stapler Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-022

Dynamic Roller Transport Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-023

Folder Transport Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-025

Press-fold Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-026

Tray Lift Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-027

Shift Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-028

Front Shift Jogger Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

* Not use: currently, VOLGA-B does not have setting jogger in system configuration.

Engine SP Mode Tables

6-124-029

Rear Shift Jogger Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

* Not use: currently, VOLGA-B does not have setting jogger in system configuration.

6-124-030

Shift Jogger Retraction Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

* Not use: currently, VOLGA-B does not have setting jogger in system configuration.

6-124-031

Drag Roller Vibrating Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-032

LE Guide Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-033

Navigation LED (All)

ENG

[0 or 1 / 0 / 1/step]

Lights all guide LED.

6-124-037

Positioning Roller Transport Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.

6-124-038

Paper Guide Motor

ENG

[0 or 1 / 0 / 1/step]

Drives specified motor for a certain period of time to test operation.



6136

[OUTPUT Check: FrontFIN]

Continuously drives specified motor for operation test.

6-136-001

Entrance Motor

*ENG

[0 or 1 / 0 / 1/step]

6-136-002

Carry Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-003

Exit Motor

ENG

[0 or 1 / 0 / 1/step]

6136

[OUTPUT Check: FrontFIN]


Drives specified motor for a certain period of time to test operation.

6-136-004

Front Jogger Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-005

Rear Jogger Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-006

Shift Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-007

Hitroll Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-008

Exit Guide Plate Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-009

Staple Moving Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-010

Tray Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-011

Staple Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-012

Stopper Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-013

Punch Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-014

Punch Moving Motor

ENG

[0 or 1 / 0 / 1/step]

6-136-015

Punch Registration Moving Motor

ENG

[0 or 1 / 0 / 1/step]

Engine SP Mode Tables



6162

[FIN (1K FIN) OUTPUT Check]

Continuously runs specified motor for operation test.

6-162-001

Entrance Transport Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-002

Proof Transport Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-003

Paper Feed/Positioning & Move Roller Motor

ENG

[0 or 1 / 0 / 1/step]

6162

[FIN (1K FIN) OUTPUT Check]

Drives specified motor for a certain period of time to test operation.

6-162-004

Junction Solenoid

ENG

[0 or 1 / 0 / 1/step]

6-162-005

Shift Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-006

Jogger Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-007

Exit Guide Plate Open/Close Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-008

Feed-out Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-009

Tray Lift Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-011

Positioning Roller Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-012

Stapler Shift Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-013

Stapler Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-014

Untitled

ENG

[0 or 1 / 0 / 1/step]

6-162-015

Untitled

ENG

[0 or 1 / 0 / 1/step]

6-162-016

Untitled

ENG

[0 or 1 / 0 / 1/step]

6-162-017

Punch Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-018

Punch Move Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-019

S-to-S Registration Detection Move Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-020

Stack Transport Motor: Upper

ENG

[0 or 1 / 0 / 1/step]

6-162-021

Stck Trns Uppr Prss Rls/Stndrd Fence Rtrct M

ENG

[0 or 1 / 0 / 1/step]

6-162-022

Stack Lower Pressure Release Motor

ENG

[0 or 1 / 0 / 1/step]

6162

[FIN (1K FIN) OUTPUT Check]

Continuously runs specified motor for operation test.

6-162-023

Folder Transport Motor

ENG

[0 or 1 / 0 / 1/step]

6162

[FIN (1K FIN) OUTPUT Check]

Drives specified motor for a certain period of time to test operation.

6-162-024

TE Stopper Motor

ENG

[0 or 1 / 0 / 1/step]

6-162-025

Folder Blade Motor

ENG

[0 or 1 / 0 / 1/step]

6162

[FIN (1K FIN) OUTPUT Check]

Lights all guide LED.

6-162-026

Navigation LED (All)

ENG

[0 or 1 / 0 / 1/step]

Engine SP Mode Tables



6185

[Output Check: NoStplBindFIN]

6-185-001

Transport Motor

ENG

[0 or 1 / 0 / 1/step]

Checks the transport motor’s movement of non staple finisher.

6-185-002

Shift Motor

ENG

[0 or 1 / 0 / 1/step]

Checks the shift motor’s movement of non staple finisher.

6-185-003

Junction Solenoid Motor

ENG

[0 or 1 / 0 / 1/step]

Checks the junction solenoid motor’s movement of non staple finisher.

6-185-004

Exit Pressure Release Motor

ENG

[0 or 1 / 0 / 1/step]

Checks the exit pressure release motor’s movement of non staple finisher.

6-185-005

Stapler Motor

ENG

[0 or 1 / 0 / 1/step]

Checks the stapler motor’s movement of non staple finisher.

    1. TEST PATTERN PRINTING


      Printing Test pattern: SP2-109

      Some of these test patterns are used for copy image adjustments but most are used primarily for design testing.

      • Do not operate the machine until the test pattern is printed out completely. Otherwise, SC will occur.

  1. Enter the SP mode then select SP2-109-003.

  2. Select test pattern for print from the list then press [OK].

  3. When selecting color for Printing; Full Color or either CMYK, go to SP2-109-005 (1: Full Color, 2: Cyan, 3: Magenta, 4: Yellow, 5: Black) to select.

  4. When changing density of test pattern, select density with SP2-109-006 through 009 for each color.

  5. To Print, Touch "Copy Window", then set settings within the following window for test print (paper size etc…).

  6. Press "Start" key to start test print.

  7. After checking test pattern, touch "SP Mode" on the LCD to return to SP mode display.

  8. Reset all settings to default values.

  9. Exit SP mode.


No.

Pattern

No.

Pattern

0

Copy image

12

Independent Pattern (2dot)

1

Vertical Line (1dot)

13

Independent Pattern (4dot)

2

Vertical Line (2dot)

14

Trimming Area

3

Horizontal Line (1dot)

15

Hound's Tooth Check (Vertical)

4

Horizontal Line (2dot)

16

Hound's Tooth Check (Horizontal)

5

Grid Vertical Line

17

Band (Horizontal)

No.

Pattern

No.

Pattern

6

Grid Horizontal Line

18

Band (Vertical)

7

Grid Pattern Small

19

Checker Flag Pattern

8

Grid Pattern Large

20

Grayscale (Vertical Margin)

9

Argyle Pattern Small

21

Grayscale (Horizontal Margin)

10

Argyle Pattern Large

22

Wormy Pattern

11

Independent Pattern (1dot)

23

Full Dot Pattern

Engine SP Mode Tables


RE V IS ION H IST ORY

Page

Date

Added/ Updated/ New



None

APPENDIX: CONTROLLER SP MODE TABLES

Controller SP Mode Tables

4. CONTROLLER SP MODE TABLES


4.1 CONTROLLER SP TABLES - SP5000


5024

4.1.1 SP5-XXX (MODE)


5009

[Add Display Language]

Adds language available in user choice. (Only the languages registered in the machine)

Refer to the displayed language list to set in the way showed below. List Number Assigned Bit Switch

No.1 to 8 BIT1 to 8 (SP5-009-201) No.9 to 16 BIT1 to 8 (SP5-009-202) No.17 to 24 BIT1 to 8 (SP5-009-203) No.25 to 32 BIT1 to 8 (SP5-009-204) No.33 to 40 BIT1 to 8 (SP5-009-205) No.41 to 48 BIT1 to 8 (SP5-009-206) No.49 to 56 BIT1 to 8 (SP5-009-207)

Example: To add American(No.3 in the list) or Czech (No.15) Turn Bit 3 of “SP5-009-201” 0 to 1 for American.

Turn Bit 7 of “SP5-009-202” 0 to 1 for Czech.

After setting, turn the main power switch off and on to make the setting valid.

5-009-201

1-8

*CTL

[1 to 255 / 0 / 1]

5-009-202

9-16

*CTL

[1 to 255 / 0 / 1]

5-009-203

17-24

*CTL

[1 to 255 / 0 / 1]

5-009-204

25-32

*CTL

[1 to 255 / 0 / 1]

5-009-205

33-40

*CTL

[1 to 255 / 0 / 1]

5-009-206

41-48

*CTL

[1 to 255 / 0 / 1]

5-009-207

49-56

*CTL

[1 to 255 / 0 / 1]



[mm/inch Display Selection]


Display units (mm or inch) for custom paper sizes.

5-024-001

0:mm 1:inch

*CTL

[0 or 1 / 1(USA), 0(Others) / 1]

0: mm

1: inch



5045

[Accounting counter]

5-045-001

Counter Method

*CTL

[0 to 7 / 1 / step]

0: Developments

1: Prints

2: Coverage

7: Coverage (YMC)



5047

[Paper Display]

5-047-001

Backing Paper

*CTL

[0 or 1 / 0 / 1]

0: OFF

1: ON



5051

[TonerRefillDetectionDisplay]

5-051-001

-

*CTL

[0 or 1 / 0 / 1]

0: ON

1: OFF



5055

[Display IP Address]

5-055-001

-

*CTL

[0 or 1 / 0 / 1]

0: OFF

1: ON



5061

[Toner Remaining Icon Display Change]

5-061-001

-

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5062

[Parts Replacement Alert Display]

5-062-002

#Photoconductor Unit (Black)

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-003

#Development unit: Bk

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-025

#Photoconductor Unit (Cyan)

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-026

#Development unit: C

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-048

#Photoconductor Unit (Magenta)

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-049

#Development unit: M

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-071

#Photoconductor Unit (Yellow)

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-072

#Development unit: Y

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-093

#Intermediate Transfer Unit

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-102

#ITB Cleaning Unit

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

Controller SP Mode Tables

5-062-109

#Paper Transfer Unit

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-115

#Fuser Unit

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-116

Fuser Unit: Belt

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-118

Fuser Unit: Pressure Roller

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-131

#Dust Filter

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-142

#Wast Toner bottle

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-206

#ADF Pick-up Roller

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-207

#ADF Paper Supply Belt

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5-062-208

#ADF Separate Roller

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display



5066

[PM Parts Display]

5-066-001

-

*CTL

[0 or 1 / 0 / 1]

0: Not display

1: Display

5067

[Part Replacement Operation Type]

5-067-002

#Photoconductor Unit (Black)

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-003

#Development unit: Bk

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-025

#Photoconductor Unit (Cyan)

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-026

#Development unit: C

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-048

#Photoconductor Unit (Magenta)

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-049

#Development unit: M

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-071

#Photoconductor Unit (Yellow)

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-072

#Development unit: Y

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-093

#Intermediate Transfer Unit

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-102

#ITB Cleaning Unit

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

Controller SP Mode Tables

5-067-109

#Paper Transfer Unit

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-115

#Fuser Unit

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-116

Fuser Unit: Belt

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-118

Fuser Unit: Pressure Roller

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-131

#Dust Filter

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-142

#Wast Toner bottle

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-206

#ADF Pick-up Roller

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-207

#ADF Paper Supply Belt

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User

5-067-208

#ADF Separate Roller

*CTL

[0 or 1 / 0 / 1]

0: Service

1: User



5071

[Set Bypass Paper Size Display]

5-071-001

-

CTL

[0 or 1 / 0 / 1]

0: Off

1: On

5073

[Supply Part Replacement Opration Type]

5-073-001

Waste Tonner Bottle

*CTL

[0 or 1 / 0 / 1] 0:No Display 1:Display

Controller SP Mode Tables



5074

[Home Screen Login]

5-074-002

Login Setting

*CTL

[0 to 255 / 0 / 1]

5-074-050

Show Home Edit Menu

*CTL

[0 to 2 / 0 / 1]

5-074-091

Function Setting

*CTL

[0 to 2 / 0 / 1]

0: Function disable

1: SDK application

2: Legacy application (reserved)

5-074-092

Product ID

*CTL

[0x00 to 0xffff / - / 1]

5-074-093

Application Screen ID

*CTL

[0 to 255 / 0 / 1]



5075

[USB Keyboard]

5-075-003

Display setting

*CTL

[0 or 1 / 0 / 1]

0: Disable

1: Enable



5081

[ServiceSP Entery Code Setting]

DFU

5-081-001

ServiceSP Entery Code Setting

-

-



5083

[LED Light Switch Setting]

5-083-001

Toner Near End

*CTL

[0 or 1 / 0 / 1]

0: OFF

1: ON

5-083-002

Waste Toner Near End

*CTL

[0 or 1 / 0 / 1]

5102

[AutoDetect]

5-102-203

HumanDetectSetting

*CTL

[0 or 1 / 0 / 1]



5114

[Optional Counter I/F]

5-114-001

MF Key Card Extension

*CTL

[0 or 1 / 0 / 1]

0: Not installed

1: Installed (scanning accounting)



5118

[Disable Copying]

5-118-001

-

*CTL

[0 or 1 / 0 / 1]

0: Not disabled

1: Disabled



5120

[Mode Clear Opt. Counter Removal]

5-120-001

0:Yes 1:StandBy 2:No

*CTL

[0 to 2 / 0 / 1]

0: Yes (removed)

1: Standby (installed but not used) 2: No (not removed)



5121

[Counter Up Timing]

5-121-001

0:Feed 1:Exit

*CTL

[0 or 1 / 0 / 1]

0: Feed

1: Exit



5127

[APS Mode]

5-127-001

-

*CTL

[0 or 1 / 0 / 1]

0: Not disabled

1: Disabled



5148

[Size Detection Off]

5-148-002

Tray 1

*CTL

[0 or 1 / 0 / 1]

5150

[Length Setting]

5-150-001

Bypass(0:OFF 1:Long)

CTL

[0 or 1 / 0 / 1]

0: OFF

1: ON

5193

Controller SP Mode Tables



5162

[App. Switch Method]

5-162-001

-

*CTL

[0 or 1 / 0 / 1] 0: Soft Key Set

1: Hard Key Set



5167

[Fax Printing Mode at Optional Counter Off]

5-167-001

-

*CTL

[0 or 1 / 0 / 1]

0: Automatic printing

1: No automatic printing



5169

[CE Login]

5-169-001


*CTL

[0 or 1 / 0 / 1]

0: Disabled

1: Enabled



5188

[Copy Nv Version]

5-188-001

-

*CTL

[- / - / -]



5191

[Mode Set]

5-191-001

Power Str Set

*CTL

[0 or 1 / 1 / 1]

0: OFF

1: ON



[External Controller Info. Settings]

5-193-001

-

CTL

[0 to 10 / 0 / 1]

0: External Controller is not installed

1: EFI

2: Ratio

3: Egret

4: GJ

5:Creo

6: QX-100

7: Kurofune

8 to 10: Reserved



5195

[Limitless SW]

5-195-001

-

*CTL

[0 or 1 / 0 / 1]

0: Productivity Precede 1: Use paper up



5196

[Copier Vendor Mode]

5-196-001

90 deg. Rotation

CTL

[0 or 1 / 0 / 1]

5-196-002

Color and Tray Selection

CTL

[0 or 1 / 0 / 1]



5199

[Paper Exit After Staple End]

5-199-001

Staple(1:Without 2:After 0:Auto)

CTL

[0 to 2 / 0 / 1]

5-199-002

Saddle(1:Without 2:After 0:Auto)

CTL

[0 to 2 / 0 / 1]

5-199-003

Stapless(1:Without 2:After 0:Auto)

CTL

[0 to 2 / 0 / 1]



5212

[Page Numbering]

5-212-003

Duplex Printout Left/Right Position of Left/Right Facing

*CTL

[-10 to 10 / 0 / 0.01mm/step]

5-212-004

Duplex Printout Top/Bottom Position of Left/Right Facing

*CTL

[-10 to 10 / 0 / 0.01mm/step]

5-212-018

Duplex Printout Left/Right Position of Top/Bottom Facing

*CTL

[-10 to 10 / 0 / 0.01mm/step]

5-212-019

Duplex Printout Top/Bottom Position of Top/Bottom Facing

*CTL

[-10 to 10 / 0 / 0.01mm/step]

Controller SP Mode Tables



5227

[Page numbering]

5-227-201

Allow Page No. Entry

*CTL

[2 to 9 / 9 / 1]

5-227-202

Zero Surplus Stting

*CTL

[0 or 1 / 0 / 1] 0:OFF

1:ON



5302

[Set Time]

Adjusts the RTC (real time clock) time setting for the local time zone. Examples: For Japan (+9 GMT), enter 540 (9 hours x 60 min.)

DOM: +540 (Tokyo)

NA: -300 (New York) EU: + 60 (Paris) CH: +480 (Beijing)

TW: +480 (Taipei)

AS: +480 (Hong Kong)

5-302-002

Time Difference

*CTL

[-1440 to 1440 / - / 1min/step]



5305

[Auto Off Set]

5-305-101

Auto Off Limit Set

*CTL

[0 or 1 / 1 / 1]



5307

[Daylight Saving Time]


5-307-001

Setting

*CTL

[0 to 1 / - / 1]

0: Disabled

1: Enabled (Default)

1: NA and EUR

0: ASIA and others


Enables or disables the summer time mode.


  • Make sure that both SP5-307-3 and -4 are correctly set. Otherwise, this SP is not activated even if this SP is set to "1".


5-307-003

Rule Set (Start)

*CTL

[0 to 0xffffffff / - / 1hex] (Default)

NA: 0x11100200 EUR: 0x10500100 ASIA: 0x03100000

Other: 0x00000000


Specifies the start setting for the summer time mode.

There are 8 digits in this SP. For months 1 to 9, the "0" cannot be input in the first digit, so the eight-digit setting for -2 or -3 becomes a seven-digit setting.

1st and 2nd digits: The month. [1 to 12] 3rd digit: The week of the month. [1 to 5]

4th digit: The day of the week. [0 to 6 = Sunday to Saturday] 5th and 6th digits: The hour. [00 to 23]

7th digit: The length of the advanced time. [0 to 9 / 1 hour ] 8th digit: The length of the advanced time. [0 to 5 / 10 minutes ]

  • The digits are counted from the left.

  • Make sure that SP5-307-1 is set to "1".


5-307-004

Rule Set (End)

*CTL

[0 to 0xffffffff / - / 1hex]

Controller SP Mode Tables

Specifies the end setting for the summer time mode. There are 8 digits in this SP.

1st and 2nd digits: The month. [1 to 12] 3rd digit: The week of the month. [0 to 5]

4th digit: The day of the week. [0 to 7 = Sunday to Saturday] 5th and 6th digits: The hour. [00 to 23]

The 7th and 8 digits must be set to "00".


5401

[Access Control]

5-401-103

Default Document ACL

CTL

[0 to 3 / 0 / 1]

5-401-104

Authentication Time

CTL

[0 to 255 / 0 / 1sec/step]

5-401-162

Extend Certification Detail

CTL

[0 to 0xff / 0 / 1]

5-401-200

SDK1 UniqueID

CTL

[0 to 0xFFFFFFFF / 0 / 1]

5-401-201

SDK1 Certification Method

CTL

[0 to 0xFF / 0 / 1]

5-401-210

SDK2 UniqueID

CTL

[0 to 0xFFFFFFFF / 0 / 1]

5-401-211

SDK2 Certification Method

CTL

[0 to 0xFF / 0 / 1]

5-401-220

SDK3 UniqueID

CTL

[0 to 0xFFFFFFFF / 0 / 1]

5-401-221

SDK3 Certification Method

CTL

[0 to 0xFF / 0 / 1]

5-401-230

SDK Certification Device

*CTL

[0 to 7 / 0 / power of 2]

0-1: SDK authentication available 0-0: Disable all functions

1-1: SKB Display

1-0: Disable

2-1: Administrator login

2-0: Disable

3 to 7-0: Reserved (set “0” only)

5-401-240

Detail Option

*CTL

[0 to 7 / 0x00 / 0x01]

0: Logout confirm option

-1: ON, 0: OFF

2 to 1: Auto-logout timer(retry timer)

-11: 30sec, 10: 20sec, 01: 10sec, 00: 60sec

3: personal authority / Group authority and operation

-1: ON, 0: OFF

4: Skip password entry

-1: ON, 0: OFF

5: Set the display of the remaining Frequence

-1: ON, 0: OFF

6 to 7: Set the display time

-1: ON, 0: OFF


5402

[Access Control]

5-402-101

SDKJ1 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-102

SDKJ2 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-103

SDKJ3 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-104

SDKJ4 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-105

SDKJ5 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-106

SDKJ6 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-107

SDKJ7 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-108

SDKJ8 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-109

SDKJ9 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-110

SDKJ10 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-111

SDKJ11 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-112

SDKJ12 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-113

SDKJ13 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-114

SDKJ14 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-115

SDKJ15 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-116

SDKJ16 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-117

SDKJ17 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-118

SDKJ18 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-119

SDKJ19 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-120

SDKJ20 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-121

SDKJ21 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-122

SDKJ22 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-123

SDKJ23 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-124

SDKJ24 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-125

SDKJ25 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-126

SDKJ26 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-127

SDKJ27 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-128

SDKJ28 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-129

SDKJ29 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-130

SDKJ30 Limit Setting

CTL

[0 to 0xff / 0 / 1]

5-402-141

SDKJ1 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-142

SDKJ2 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-143

SDKJ3 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-144

SDKJ4 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-145

SDKJ5 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-146

SDKJ6 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-147

SDKJ7 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-148

SDKJ8 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-149

SDKJ9 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-150

SDKJ10 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-151

SDKJ11 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-152

SDKJ12 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

Controller SP Mode Tables

5-402-153

SDKJ13 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-154

SDKJ14 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-155

SDKJ15 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-156

SDKJ16 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-157

SDKJ17 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-158

SDKJ18 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-159

SDKJ19 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-160

SDKJ20 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-161

SDKJ21 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-162

SDKJ22 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-163

SDKJ23 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-164

SDKJ24 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-165

SDKJ25 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-166

SDKJ26 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-167

SDKJ27 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-168

SDKJ28 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-169

SDKJ29 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5-402-170

SDKJ30 ProductID

CTL

[0 to 0xffffffff / 0 / 1]

5411



5404

[User Code Count Clear]

5-404-001

User Code Count Clear

*CTL

[- / - / -]

[Execute]

5-404-101

User Code Count Clear Permit Setting

*CTL

[0 or 1 / 0 / 1]



[LDAP-Certification]

5-411-004

Easy Certification

*CTL

[0 or 1 / 1 / 1]

1: On

0: Off

5-411-005

Password Null Not Permit

*CTL

[0 or 1 / 0 / 1]

0: Password NULL not permitted. 1: Password NULL permitted.

5-411-006

Detail Option

*CTL

[0 or 1 / 0 / 1]

0: OFF

1: ON

Controller SP Mode Tables



5412

[Krb-Certification]

5-412-100

Encrypt Mode

CTL

[0 to 0xFF / 0x1F / 1]



5413

[Lockout Setting]

5-413-001

Lockout On/Off

*CTL

[0 or 1 / 0 / 1]

0: Off

1: On

5-413-002

Lockout Threshold

*CTL

[1 to 10 / 5 / 1]

5-413-003

Cancellation On/Off

*CTL

[0 or 1 / 0 / 1]

0: Off (no wait time, lockout not cancelled)

1: On (system waits, cancels lockout if correct user ID and password are entered.

5-413-004

Cancellation Time

*CTL

[1 to 9999 / 60 / 1min]



5414

[Access Mitigation]

5-414-001

Mitigation On/Off

*CTL

[0 or 1 / 0 / 1]

0: OFF

1: ON

5-414-002

Mitigation Time

*CTL

[0 to 60 / 15 / 1min/step]

5415

[Password Attack]

5-415-001

Permissible Number

*CTL

[0 to 100 / 30 /1attempt/step]

5-415-002

Detect Time

*CTL

[1 to 10 / 5 / 1sec/step]



5416

[Access Information]

5-416-001

Access User Max Num

*CTL

[50 to 200 / 200 / 1user/step]

5-416-002

Access Password Max Num

*CTL

[50 to 200 / 200 / 1password/step]

5-416-003

Monitor Interval

*CTL

[1 to 10 / 3 / 1sec/step]



5417

[Access Attack]

5-417-001

Access Permissible Number

*CTL

[0 to 500 / 100 / 1/step]

5-417-002

Attack Detect Time

*CTL

[10 to 30 / 10 / 1sec/step]

5-417-003

Productivity Fall Wait

*CTL

[0 to 9 / 3 / 1sec/step]

5-417-004

Attack Max Num

*CTL

[50 to 200 / 200 / 1attempt/step]



5420

[User Authentication]

5-420-001

Copy

*CTL

[0 to 1 / 0 / 1]

0: On

1: Off

5-420-002

Color Security Setting

*CTL

[0x00 to 0xFF / 0x00 / 1]

5-420-011

DocumentServer

*CTL

[0 or 1/ 0 / 1]

0: On

1: Off

5-420-021

Fax

*CTL

[0 or 1/ 0 / 1]

0: On

1: Off

5-420-031

Scanner

*CTL

[0 or 1/ 0 / 1]

0: On

1: Off

5-420-041

Printer

*CTL

[0 or 1/ 0 / 1]

0: On

1: Off

5-420-051

SDK1

*CTL

[0 or 1 / 0 / 1]

0: ON

1: OFF

5-420-061

SDK2

*CTL

5-420-071

SDK3

*CTL

5-420-081

Browser

*CTL

[0 or 1 / 0 / 1]

0: ON

1: OFF

Controller SP Mode Tables



5430

[Auth Dialog Message Change]

5-430-001

Message Change On/Off

CTL

[0 or 1 / 0 / 1]

5-430-002

Message Text Download

CTL

[- / - / -]

5-430-003

Message Text ID

CTL

[- / - / -]



5431

[External Auth User Preset]

5-431-010

Tag

CTL

[0 or 1 / 1 / 1]

5-431-011

Entry

CTL

[0 or 1 / 1 / 1]

5-431-012

Group

CTL

[0 or 1 / 1 / 1]

5-431-020

Mail

CTL

[0 or 1 / 1 / 1]

5-431-030

Fax

CTL

[0 or 1 / 1 / 1]

5-431-031

FaxSub

CTL

[0 or 1 / 1 / 1]

5-431-032

Folder

CTL

[0 or 1 / 1 / 1]

5-431-033

ProtectCode

CTL

[0 or 1 / 1 / 1]

5-431-034

SmtpAuth

CTL

[0 or 1 / 1 / 1]

5-431-035

LdapAuth

CTL

[0 or 1 / 1 / 1]

5-431-036

Smb Ftp Fldr Auth

CTL

[0 or 1 / 1 / 1]

5-431-037

AcntAcl

CTL

[0 or 1 / 1 / 1]

5-431-038

DocumentAcl

CTL

[0 or 1 / 1 / 1]

5-431-040

CertCrypt

CTL

[0 or 1 / 0 / 1]

5-431-050

UserLimitCount

CTL

[0 or 1 / 1 / 1]

5504



5481

[Authentication Error Code]

5-481-001

System Log Disp

*CTL

[0 or 1 / 0 / 1]

0: Off

1: On

5-481-002

Panel Disp

*CTL

[0 or 1 / 0 / 1]

1: On

0: Off



5490

[MF KeyCard (Japan only)]

5-490-001

Job Permit Setting

*CTL

[0 to 1 / 0 / 1]

0: Disabled. Cancels operation without a user code.

1: Enabled. Allows operation without a user code.

5-490-002

Count Mode Setting

*CTL

-



5491

[Optional Counter]

5-491-001

Detail Option

*CTL

[0 to 0xff / 0 / 1]



5501

[PM Alarm]

5-501-001

PM Alarm Level

*CTL

[0 to 9999 / 0 / 1]

0: Alarm off

1 to 9999: Alarm goes off when Value (1 to 9999) x 1000 > PM counter



[Jam Alarm]

5-504-001

-

*CTL

[0 to 3 / 3 / 1]

0: Z

1: L

2: M

3: H

5-504-002

Threshold

*CTL

[1 to 99 / 10 / 1]

Controller SP Mode Tables



5505

[Error Alarm]

5-505-001

Error Alarm

*CTL

[0 to 255 / * / 1 x102 sheets/step]

0: Alarm Off

* C2503 :20 / C2003:15

5-505-002

Threshold

*CTL

[1 to 99 / 5 / 1]



5507

[Supply/CC Alarm]

5-507-001

Paper Supply Alarm

*CTL

[0 or 1 / 0 / 1]

0: OFF

1: ON

5-507-002

Staple Supply Alarm

*CTL

[0 or 1 / 0 / 1]

0: OFF

1: ON

5-507-003

Toner Supply Alarm

*CTL

[0 or 1 / 0 / 1]

0: OFF

1: ON

5-507-006

WasteTonerBottle

*CTL

[0 to 2 / 1 / 1] 0:OFF

1: Supply Call ON 2: CC Call ON

5-507-080

Toner Call Timing

*CTL

[0 or 1 / 0 / 1]

0: Toner bottle replacement 1: Less than toner threshold

5-507-080

Toner Call Timing

CTL

[0 or 1 / 0 / 1]

5-507-081

Toner Call Threshold:Bk

CTL

[10 to 90 / 10 / 10%/step]

5-507-082

Toner Call Threshold:CMY

CTL

[10 to 90 / 10 / 10%/step]

5-507-128

Interval :Others

*CTL

[250 to 10000 / 1000 /

1page/step]

5-507-132

Interval :A3

*CTL

[250 to 10000 / 1000 /

1page/step]

5-507-133

Interval :A4

*CTL

[250 to 10000 / 1000 /

1page/step]

5-507-134

Interval :A5

*CTL

[250 to 10000 / 1000 /

1page/step]

5-507-141

Interval :B4

*CTL

[250 to 10000 / 1000 /

1page/step]

5-507-142

Interval :B5

*CTL

[250 to 10000 / 1000 /

1page/step]

5-507-160

Interval :DLT

*CTL

[250 to 10000 / 1000 /

1page/step]

5-507-164

Interval: LG

*CTL

[250 to 10000 / 1000 /

1page/step]

5-507-166

Interval :LT

*CTL

[250 to 10000 / 1000 /

1page/step]

5-507-172

Interval :HLT

*CTL

[250 to 10000 / 1000 /

1page/step]



5508

[CC Call]

5-508-001

Jam Remains

*CTL

[0 or 1 / 1 / 1]

0: Disable

1: Enable

5-508-002

Continuous Jams

*CTL

[0 or 1 / 1 / 1]

0: Disable

1: Enable

5-508-003

Continuous Door Open

*CTL

[0 or 1 / 1 / 1]

0: Disable

1: Enable

5-508-011

Jam Detection: Time Length

*CTL

[3 to 30 / 10 / 1min/step]

5-508-012

Jam Detection: Continuous Count

*CTL

[2 to 10 / 5 / 1time/step]

5-508-013

Door Open: Time Length

*CTL

[3 to 30 / 10 / 1min/step]

Controller SP Mode Tables



5513

[PartsAlermlevelCount]

5-513-001

Normal

*CTL

[1 to 9999 / 300 / 1]

5-513-002

Df

*CTL

[1 to 9999 / 300 / 1]



5514

[PartsAlermlev]

5-514-001

Normal

*CTL

[0 or 1 / 1 / 1]

5-514-002

Df

*CTL

[0 or 1 / 0 / 1]



5515

[SC/Alarm Setting]

5-515-001

SC Call

*CTL

[0 or 1 / 1 / 1]

0: OFF

1: ON

5-515-002

Service Parts Near End Call

*CTL

5-515-003

Service Parts End Call

*CTL

5-515-004

User Call

*CTL

5-515-006

Communication Test Call

*CTL

5-515-007

Machine Information Notice

*CTL

5-515-008

Alarm Notice

*CTL

5-515-009

Non Genuine Tonner Ararm

*CTL

5-515-010

Supply Automatic Ordering Call

*CTL


5-515-011

Supply Management Report Call

*CTL

5-515-012

Jam/Door Open Call

*CTL

5-515-050

Timeout:Manual Call

*CTL

[1 to 255 / 5 / 1min/step]

5-515-051

Timeout:Other Call

*CTL

[1 to 255 / 10 / 1min/step]



5517

[Get Machine Information]

5-517-031

Get SMC Info: Retry Interval

*CTL

[10 to 255 / 10 / 1min/step]



5618

[Color Mode Display Selection]

5-618-001

-

*CTL

[0 or 1 / 1 / 1]

0: ACS, Color, Black & White, Two Colors, Single color

1: ACD, Full Color, Black & White



5728

[Network Setting]

5-728-001

NAT Machine Port1

CTL

[1 to 65535 / 49101 / 1]

5-728-002

NAT UI Port1

CTL

[1 to 65535 / 55101 / 1]

5-728-003

NAT Machine Port2

CTL

[1 to 65535 / 49102 / 1]

5-728-004

NAT UI Port2

CTL

[1 to 65535 / 55102 / 1]

5-728-005

NAT Machine Port3

CTL

[1 to 65535 / 49103 / 1]

5-728-006

NAT UI Port3

CTL

[1 to 65535 / 55103 / 1]

5-728-007

NAT Machine Port4

CTL

[1 to 65535 / 49104 / 1]

5-728-008

NAT UI Port4

CTL

[1 to 65535 / 55104 / 1]

5-728-009

NAT Machine Port5

CTL

[1 to 65535 / 49105 / 1]

5-728-010

NAT UI Port5

CTL

[1 to 65535 / 55105 / 1]

5-728-011

NAT Machine Port6

CTL

[1 to 65535 / 49106 / 1]

5-728-012

NAT UI Port6

CTL

[1 to 65535 / 55106 / 1]

5-728-013

NAT Machine Port7

CTL

[1 to 65535 / 49107 / 1]

5-728-014

NAT UI Port7

CTL

[1 to 65535 / 55107 / 1]

5-728-015

NAT Machine Port8

CTL

[1 to 65535 / 49108 / 1]

5-728-016

NAT UI Port8

CTL

[1 to 65535 / 55108 / 1]

5-728-017

NAT Machine Port9

CTL

[1 to 65535 / 49109 / 1]

5-728-018

NAT UI Port9

CTL

[1 to 65535 / 55109 / 1]

5-728-019

NAT Machine Port10

CTL

[1 to 65535 / 49110 / 1]

5-728-020

NAT UI Port10

CTL

[1 to 65535 / 55110 / 1]

5741

Controller SP Mode Tables



5730

[Extended Function Setting]

5-730-001

JavaTM Platform setting

*CTL

[0 or 1 / 1 / -]

0: Disable, 1: Enable

5-730-010

Expiration Prior Alarm Set

*CTL

[0 to 999 / 20 / 1day/step]



5731

[Counter Effect]

This SP is used only for DOM machines.

5-731-001

Change MK1 Cnt (Paper->Combine)

*CTL

[0 or 1 / 0 / 1]



5732

[Reset Job After Jam(Copy)]

5-732-002


*CTL

[0 or 1 / 0 / 1]



5734

[PDF Setting]

5-734-001

PDF/A Fixed

*CTL

[0 or 1 / 0 / 1]



[Node Authentication Timuout]

5-741-001


*CTL

[1 to 255 / 60 / 1sec/step]



5745

[DeemedPowerConsumption]

5-745-211

Controller Standby

*CTL

[0 to 9999 / 0 / 1]

5-745-212

STR

*CTL

[0 to 9999 / 0 / 1]

5-745-213

Main Power Off

*CTL

[0 to 9999 / 0 / 1]

5-745-214

Scanning and Printing

*CTL

[0 to 9999 / 0 / 1]

5-745-215

Printing

*CTL

[0 to 9999 / 0 / 1]

5-745-216

Scanning

*CTL

[0 to 9999 / 0 / 1]

5-745-217

Engine Standby

*CTL

[0 to 9999 / 0 / 1]

5-745-218

Low Power Consumption

*CTL

[0 to 9999 / 0 / 1]

5-745-219

Silent condition

*CTL

[0 to 9999 / 0 / 1]

5-745-220

Heater Off

*CTL

[0 to 9999 / 0 / 1]



5748

[OpePanel Setting]

5-748-101

Op Type Action Setting

CTL

[0x00 to 0xFF / 0 / 0x01]

  • bit0

0: Normal operation panel 1: Smart operation panel

5-748-201

Cheetah Panel Connect Setting

CTL

[0 or 1 / 0 / 0]

0: OFF

1: ON



5749

[Import/Export]

5-749-001

Export

CTL

[- / - / -]

Target: System, Printer, Fax, Scanner Option: Unique, Secret

Copy config: Encryption, Encryption key(if selected)

[Execute]

5-749-101

Import

CTL

[- / - / -]

Option: Unique

Copy config: Encryption, Encryption key(if selected)

[Execute]

Controller SP Mode Tables



5751

[Key Event Encryption Setting]

5-751-001

Password

CTL

[0 to 255 / 0 / 1]



5752

[Copy:WebAPI Setting]

5-752-001

Copy FlairAPI Setting

*CTL

* see BitSwitch below:


Bit


Setting

meanings


Description

0

1

bit 0

Start of FlairAPI Server

Off (Do not Start)

On (Start)

Sets whether to start exclusive FlairAPI http server. If it is 0, scanning FlairAPI function and simple UI function will be disabled. The machine installed Android operating panel option, set “1”, others set “0”.

bit 1

Access permission of FlairAPI from outside of the machine

Disabled

Enabled

If it is “0”, accessing is limited from the machine only, such as operating panel, SDK/J, MFP browsers etc... If it is “1”, accessing is allowed from outside of FlairAPI such as PC, Remote UI, IT-Box etc...

bit 2

Reserved

-

-

-

bit 3

Reserved

-

-

-

bit 4

Simple UI Function

Disabled

Enabled

If it is “1”, the machine can be used Scanner Simple UI. If it is “0”, requesting URL of Simple UI returns “404 Not Found”

bit 5

Accessing permission of Simple UI from outside of the machine

Disabled

Enabled

If it is “0”, accessing is limited from the machine only (operating panel and MFP browser). If it is “1”, accessing is allowed from outside of Simple UI such as PC, mobile devices, and so on.

bit 6

Reserved

-

-

-

bit 7

Reserved

-

-

-

5801



5755

[Display Setting]

5-755-001

Disp Administrator Password Change Scrn

CTL

[- / - / -]

5-755-002

Hide Administrator Password Change Scrn

CTL

[- / - / -]



5758

[RemoteUI Setting]

5-758-001

Authentication

*CTL

[0 or 1 / 0 / 1]



5759

[Machine Limit Count]

5-759-001

Machine Limit Count Setting

*CTL

[0 or 1 / 0 / 1]

5-759-061

Full Color Limit Count

*CTL

[0 to 99999999 / 0 / 1]

5-759-062

Mono Color Limit Count

*CTL

[0 to 99999999 / 0 / 1]



[Memory Clear]

5-801-001

All Clear

CTL

[- / - / -]

[Execute]

5-801-003

SCS

CTL

[- / - / -]

[Execute]

5-801-004

IMH Memory Clr

CTL

[- / - / -]

[Execute]

5-801-005

Mcs

CTL

[- / - / -]

[Execute]

5-801-006

Copier Application

CTL

[- / - / -]

[Execute]

5-801-007

Fax Application

CTL

[- / - / -]

[Execute]

5-801-008

Printer Application

CTL

[- / - / -]

[Execute]

The following service settings:

  • Bit switches

  • Gamma settings (User & Service)

  • Toner Limit

  • Tray Priority

  • Menu Protect

  • System Setting except for setting of Energy Saver

  • I/F Setup (I/O Buffer and I/O Timeout)

  • PCL Menu

The following user settings:

5-801-009

Scanner Application

CTL

[- / - / -]

[Execute]

5-801-010

Web Service

CTL

[- / - / -]

[Execute]

5-801-011

NCS

CTL

[- / - / -]

[Execute]

5-801-012

R-Fax

CTL

[- / - / -]

[Execute]

Controller SP Mode Tables

5-801-014

Clear DCS Setting

CTL

[- / - / -]

[Execute]

5-801-015

Clear UCS Setting

CTL

[- / - / -]

[Execute]

5-801-016

MIRS Memory Clr

CTL

[- / - / -]

[Execute]

5-801-017

CCS

CTL

[- / - / -]

[Execute]

5-801-018

SRM Memory Clr

CTL

[- / - / -]

[Execute]

5-801-019

LCS Memory Clr

CTL

[- / - / -]

[Execute]

5-801-020

Web Uapli

CTL

[- / - / -]

[Execute]

5-801-021

ECS

CTL

[- / - / -]

[Execute]

5-801-023

AICS

CTL

[- / - / -]

[Execute]

5-801-025

Websys

CTL

[- / - / -]

[Execute]

5-801-026

PLN

CTL

[- / - / -]

[Execute]

5-801-027

SAS

CTL

[- / - / -]

[Execute]

5-801-028

Rest WebService

CTL

[- / - / -]

[Execute]

5816

[Remote Service]


5-816-001

I/F Setting

*CTL

[0 to 2 / 2 / 1]

0: Remote service off

1: CSS remote service on 2: NRS remote service on


5-816-002

CE Call

*CTL

[0 or 1 / 0 / 1]

0: Start of the service 1: End of the service


5-816-003

Function Flag

*CTL

[0 or 1 / 0 / 1]

0: Disabled

1: Enabled


5-816-007

SSL Disable

*CTL

[0 or 1 / 0 / 1]

0: Yes. SSL not used. 1: No. SSL used.


5-816-008

RCG Connect Timeout

*CTL

[1 to 90 / 30 / 1second/step]


5-816-009

RCG Write Timeout

*CTL

[0 to 100 / 60 / 1second/step]


5-816-010

RCG Read Timeout

*CTL

[0 to 100 / 60 / 1second/step]


5-816-011

Port 80 Enable

*CTL

[0 or 1 / 0 / 1]

0: No. Access denied 1: Yes. Access granted.


5-816-013

RFU Timing

*CTL

[0 or 1 / 1 / 1]

0: Any status of a target machine 1: Sleep or panel off mode only


5-816-014

RCG Error Cause

CTL

[0 or 1 / 0 / 1]

0: Initial state, normal condition 1: Error


5-816-021

RCG – C Registed

*CTL

[0 or 1 / 0 / 1]

0: Installation not completed 1: Installation completed


5-812-003

Supply

*CTL

[up to 20 / - / 1]

5-812-004

Operation

*CTL

[up to 20 / - / 1]

Controller SP Mode Tables



5812

[Service Tel. No. Setting]

5-812-001

Service

*CTL

[up to 20 / - / 1]

5-812-002

Facsimile

*CTL

[up to 20 / - / 1]

5-816-023

connect type(N/M)

*CTL

[0 or 1 / 0 / 1]

0: internet connection

1: Dial-up connection


5-816-061

Cert Expire Timing

*CTL

[0 to 0xffffffff / 0 / 1]

0: Not use

1: Use


5-816-062

Use Proxy

*CTL

[0 or 1 / 0 / 1]

0: Not use

1: Use


5-816-063

Proxy Host

*CTL

[- / - / -]


5-816-064

Proxy PortNumber

*CTL

[0 to 0xffff / 0 / 1]


5-816-065

Proxy User Name

*CTL

[up to 31 / - / 1]


5-816-066

Proxy Password

*CTL

[up to 31 / - / 1]


5-816-067

Proxy Password

*CTL

[0 to 255 / 0 / 1]


Displays status of the certification used for Cumin.

If it is not installed as Cumin, the value of this SP will be set when it installed, after checking the certification status.


0

The certification adequately set on the machine.

1

Request for certification update in progress.

2

Certification Update completed and notification of the success status to the G/W in progress.

3

Certification Update failed and notification of the result to the G/W in progress.

4

Certification expiration date will be coming soon. Notifying the G/W to request for certification update.

11

Rescue certification setting for connecting to the rescue G/W in progress because update for rescue certification needed.

12

Setting for rescue certification has completed. Requesting to the rescue G/W for updating certification.


13

Notification for certification updating request has completed. Waiting for the certification update request from the rescue G/W.

14

Received the notification for certification updating request from the rescue G/W. Writing the certification.

15

Writing the certification has completed. Notifying the result of certification update to the G/W.

16

Writing the certification has failed. Notifying the result of certification update to the G/W.

17

Writing a rescue certification because received a certification error again after completed the certification update request from the G/W and noticed the result of certification update with the updated certification.

18

The writing operation mentioned in #17 has completed. Notifying the result of certification update to the rescue G/W.


5-816-068

CERT: Error

*CTL

[0 to 255 / 0 / 1]


Displays a number code that describes the reason for the request for update of the certification.


0

Normal. There is no request for certification update in progress.

1

Request for certification update in progress. The current certification has expired.

2

An SSL error notification has been issued. Issued after the certification has expired.

3

Notification of shift from a common authentication to an individual certification.

4

Notification of a common certification without ID2.

5

Notification that no certification was issued.

6

Notification that GW URL does not exist.


5-816-069

CERT: Up ID

*CTL

[- / - / -]


-


Controller SP Mode Tables

5-816-083

Firm Up Status

*CTL

[0 to 5 / 0 / 1]

0: Waiting for accepting firm update

1: Waiting for firm update start schedule

2: Waiting for user confirmation 3: In preparation for the machine firm update

4: processing the machine firm update

5: processing the closing operation of the machine firm update


5-816-085

Firm Up User Check

CTL

[- / - / -]


5-816-086

Firmware Size

CTL

[- / - / -]


5-816-087

CERT:Macro Ver.

CTL

[8digits / - / 1digit/step]


5-816-088

CERT:PAC Ver.

CTL

[16digits / - / 1digit/step]


5-816-089

CERT:ID2Code

CTL

[17digits / - / 1digit/step]


5-816-090

CERT:Subject

CTL

[17digits / - / 1digit/step]


5-816-091

CERT:Serial No.

CTL

[16digits / - / 1digit/step]


5-816-092

CERT:Issuer

CTL

[30digits / - / 1digit/step]


5-816-093

CERT:Valid Start

CTL

[10digits / - / 1digit/step]


5-816-094

CERT:Valid End

CTL

[10digits / - / 1digit/step]


5-816-102

CERT:Encrypt Level

*CTL

[1 to 2 / 1 / 1]


5-816-103

Client Communication Method

CTL

[0 to 3 / 0 / 1]


5-816-104

Client Communication Limit

CTL

[1 to 7 / 7 / 1]


5-816-115

Network Information Waiting timer

CTL

[5 to 255 / 5 / 1sec/step]


5-816-150

Selection Country

CTL

[0 to 10 / 1 / 1]

0: Japan

1: USA

2: Canada

3: UK

4: Germany

5: France

6: Italy

7: Netherlands

8: Belgium

9: Luxembourg

10: Spain


Select the country where embedded RCG-M is installed in the machine. After selecting the country, you must also set the following SP codes for embedded RCG-M:

  • SP5816-153

  • SP5816-154

  • SP5816-161


5-816-151

Line Type AutomaticJudgment

CTL

[- / - / -]

[Execute]


5-816-152

Line Type Judgment Result

CTL

[0 to 9 / - / 1]


Displays a number to show the result of the execution of SP5816 151. Here is a list of what the numbers mean.

0: Success

1: In progress (no result yet). Please wait. 2: Line abnormal

3: Cannot detect dial tone automatically 4: Line is disconnected

5: Insufficient electrical power supply 6: Line classification not supported

7: Error because fax transmission in progress – ioctl() occurred. 8: Other error occurred

9: Line classification still in progress. Please wait.